Literature DB >> 1020409

[Contribution to the continuous indirect blood pressure measurement].

J Penáz, A Voigt, W Teichmann.   

Abstract

The plethysmanometer described follows the principle of the relaxed wall of the vessel. Here the pressure is adjusted in a finger cuff and by means of a pneumatic regulation is varied in such a way that the light plethysmogram of the adequate finger does not show any more pulsations. Thus the pressure effected on the finger above the cuff corresponds to the pressure in the finger arteries and is to be registered in mm Hg. When the course is measured in the same test person with changing of the arterial pressure (e.g. absolute arrhythmia or compressed-air pressure experiment) the blood pressure of the aorta measured when a heart catheter is diagnostically indicated shows a very close correlation to the unbloodily registered pressure of the finger arteries. On the other hand, greater varieties of the correlation coefficient which can be proved from test person to test person at present do not yet allow a formula obligatory in general, in order to tansfer the value unbloodily measured into the adequate bloody one. Nevertheless, already nowadays great ranges of application are possible for the progressing measuring of the blood pressure.

Entities:  

Mesh:

Year:  1976        PMID: 1020409

Source DB:  PubMed          Journal:  Z Gesamte Inn Med        ISSN: 0044-2542


  48 in total

1.  Joint symbolic dynamic analysis of beat-to-beat interactions of heart rate and systolic blood pressure in normal pregnancy.

Authors:  M Baumert; T Walther; J Hopfe; H Stepan; R Faber; A Voss
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

2.  On the reliability of the Penaz cuff during systemic and local fingertip vasodilatation at rest and in exercise.

Authors:  W Hildebrandt; H Schütze; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

3.  Influence of age on linear and nonlinear measures of autonomic cardiovascular modulation.

Authors:  Michael K Boettger; Steffen Schulz; Sandy Berger; Manuel Tancer; Vikram K Yeragani; Andreas Voss; Karl-Jürgen Bär
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-04       Impact factor: 1.468

4.  Baroreflex analysis in diabetes mellitus: linear and nonlinear approaches.

Authors:  Michal Javorka; Zuzana Lazarova; Ingrid Tonhajzerova; Zuzana Turianikova; Natasa Honzikova; Bohumil Fiser; Kamil Javorka; Mathias Baumert
Journal:  Med Biol Eng Comput       Date:  2010-11-19       Impact factor: 2.602

5.  Reliability of blood pressure determination with the Finapres with altered physiological states or pharmacodynamic conditions.

Authors:  D McAuley; B Silke; S Farrell
Journal:  Clin Auton Res       Date:  1997-08       Impact factor: 4.435

6.  Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients.

Authors:  Julia Y Wagner; Ileana Negulescu; Miriam Schöfthaler; Alexander Hapfelmeier; Agnes S Meidert; Wolfgang Huber; Roland M Schmid; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-03-01       Impact factor: 2.502

7.  [Principles and pitfalls of arterial blood pressure measurement].

Authors:  A S Meidert; J Briegel; B Saugel
Journal:  Anaesthesist       Date:  2019-09       Impact factor: 1.041

8.  Differential vascular reactivity responses acutely following ingestion of a nitrate rich red spinach extract.

Authors:  Cody T Haun; Wesley C Kephart; Angelia M Holland; Christopher B Mobley; Anna E McCloskey; Joshua J Shake; David D Pascoe; Michael D Roberts; Jeffrey S Martin
Journal:  Eur J Appl Physiol       Date:  2016-09-30       Impact factor: 3.078

9.  Short-term postural reflexes in diabetic patients with autonomic dysfunction.

Authors:  Y Zhang; L A Critchley; Y H Tam; B Tomlinson
Journal:  Diabetologia       Date:  2003-12-03       Impact factor: 10.122

10.  Reduction in extracellular muscle volume increases heart rate and blood pressure response to isometric exercise.

Authors:  K Baum; D Essfeld; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.