Quantitative histological analysis of bony ingrowth within the biomaterial Polyactive implanted in different bone locations: an experimental study in rabbits.

S J Bouwmeester1, R Kuijer, M M Sollie-Drees, A J van der Linden, S K Bulstra.   

Abstract

The quantity of bone formed in cylinders of a newly developed erodible copolymer, Polyactive (PA60/40) was examined. PA60/40 was implanted in three different bone locations in the rabbit: in the cortex, in bone marrow and in trabecular subchondral bone. Bony ingrowth was assessed after 4, 8, 26 and 52 w after the operation and investigated by histology and image analysis. The ingrowth of bone was observed in PA60/40 placed in the cortex from 4 w onwards. After 8 w, more than 90% of the pores of the biomaterial were filled with dense bone. In bone marrow, initially some bone formation was seen. After 26 w, all newly formed bone was resorbed. Subchondral bone formation was less than in the cortex of the femur, but somewhat comparable to the amount of bone found in healthy trabecular bone. Bone formation appeared not to be affected by the degradation of the biomaterial. It was concluded that Polyactive is a suitable bone graft substitute. Bone formation within PA60/40 is site-dependent and this follows Wolff 's law. Copyright 1998 Chapman & Hall

Entities:  

Year:  1998        PMID: 15348889     DOI: 10.1023/a:1008875821298

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  18 in total

1.  The early host and material response of bone-bonding and non-bonding glass-ceramic implants as revealed by scanning electron microscopy and histochemistry.

Authors:  C Müller-Mai; C Voigt; W Knarse; J Sela; U M Gross
Journal:  Biomaterials       Date:  1991-11       Impact factor: 12.479

2.  Bioreactions at the tissue/hydroxyapatite interface.

Authors:  C A van Blitterswijk; J J Grote; W Kuÿpers; C J Blok-van Hoek; W T Daems
Journal:  Biomaterials       Date:  1985-07       Impact factor: 12.479

3.  Bone banking. In support of reconstructive surgery of the hip.

Authors:  G E Friedlaender
Journal:  Clin Orthop Relat Res       Date:  1987-12       Impact factor: 4.176

4.  Experimental study on demineralized bone matrix (DBM) and coral as bone graft substitutes in maxillofacial surgery.

Authors:  L Dupoirieux; V Costes; P Jammet; F Souyris
Journal:  Int J Oral Maxillofac Surg       Date:  1994-12       Impact factor: 2.789

5.  Local stresses and bone adaption around orthopedic implants.

Authors:  R Huiskes; D Nunamaker
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

6.  A determinant of bone architecture. The minimum effective strain.

Authors:  H M Frost
Journal:  Clin Orthop Relat Res       Date:  1983-05       Impact factor: 4.176

7.  Autogeneic bone marrow and porous biphasic calcium phosphate ceramic for segmental bone defects in the canine ulna.

Authors:  R E Grundel; M W Chapman; T Yee; D C Moore
Journal:  Clin Orthop Relat Res       Date:  1991-05       Impact factor: 4.176

8.  Bone ingrowth and mechanical properties of coralline hydroxyapatite 1 yr after implantation.

Authors:  R B Martin; M W Chapman; N A Sharkey; S L Zissimos; B Bay; E C Shors
Journal:  Biomaterials       Date:  1993-04       Impact factor: 12.479

Review 9.  Anterior cervical discectomy and fusion using a porous hydroxyapatite bone graft substitute.

Authors:  T A Zdeblick; M E Cooke; D N Kunz; D Wilson; R P McCabe
Journal:  Spine (Phila Pa 1976)       Date:  1994-10-15       Impact factor: 3.468

10.  [Clinical application of AW glass ceramic prosthesis in spinal surgery].

Authors:  T Yamamuro; K Shimizu
Journal:  Nihon Seikeigeka Gakkai Zasshi       Date:  1994-07
View more
  2 in total

Review 1.  Osteolysis in cemented total hip arthroplasty involving the OptiPlug cement restrictor: more than an incident?

Authors:  N M A I Hanssen; M G M Schotanus; A D Verburg
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-28

2.  Physical and mechanical behavior of electron-beam irradiated and ethylene oxide sterilized multiblock polyester.

Authors:  M E Fray; A Bartkowiak; P Prowans; J Slonecki
Journal:  J Mater Sci Mater Med       Date:  2000-11       Impact factor: 3.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.