Literature DB >> 7761004

Spiral CT of the temporal bone: value of image reconstruction at submillimetric table increments.

R Hermans1, G Marchal, L Feenstra, A L Baert.   

Abstract

Axial spiral CT of the temporal bones with a nominal slice thickness of 1 mm and 180 degrees linear interpolation was performed in 13 patients. In 18 temporal bones, the spiral data set was used to reconstruct overlapping axial images with a table increment of 0.1 mm. These images gave additional information in four cases: in two by examining the heavily overlapping axial images themselves, and in two by obtaining supplementary information from secondary image reconstructions. In two cases less information was obtained than by using the conventional incremental images. This study shows that reconstructing overlapping slices can be useful, even if the temporal bone is scanned at 1 mm nominal slice thickness.

Entities:  

Mesh:

Year:  1995        PMID: 7761004     DOI: 10.1007/BF00588634

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  10 in total

1.  Evaluation of section sensitivity profiles and image noise in spiral CT.

Authors:  A Polacin; W A Kalender; G Marchal
Journal:  Radiology       Date:  1992-10       Impact factor: 11.105

2.  Initial experience with volume CT scanning.

Authors:  H Rigauts; G Marchal; A L Baert; R Hupke
Journal:  J Comput Assist Tomogr       Date:  1990 Jul-Aug       Impact factor: 1.826

3.  Physical performance characteristics of spiral CT scanning.

Authors:  W A Kalender; A Polacin
Journal:  Med Phys       Date:  1991 Sep-Oct       Impact factor: 4.071

4.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.

Authors:  W A Kalender; W Seissler; E Klotz; P Vock
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

5.  Direct sagittal CT in the evaluation of temporal bone disease.

Authors:  M F Mafee; A Kumar; C N Tahmoressi; B C Levin; C F James; R Kriz; V Capek
Journal:  AJR Am J Roentgenol       Date:  1988-06       Impact factor: 3.959

6.  Direct sagittal computed tomography of the temporal bone.

Authors:  J V Manzione; C L Rumbaugh; R W Katzberg
Journal:  J Comput Assist Tomogr       Date:  1985 Mar-Apr       Impact factor: 1.826

7.  A comparison of conventional and spiral CT: an experimental study on the detection of spherical lesions.

Authors:  W A Kalender; A Polacin; C Süss
Journal:  J Comput Assist Tomogr       Date:  1994 Mar-Apr       Impact factor: 1.826

8.  High-resolution CT of the petrous bone: direct vs. Reformatted images.

Authors:  P Turski; D Norman; J DeGroot; R Capra
Journal:  AJNR Am J Neuroradiol       Date:  1982 Jul-Aug       Impact factor: 3.825

9.  Clinical significance of partial volume averaging of the temporal bone.

Authors:  D W Chakeres
Journal:  AJNR Am J Neuroradiol       Date:  1984 May-Jun       Impact factor: 3.825

10.  The value of non-reconstructive multiplanar CT for the evaluation of the petrous bone.

Authors:  F W Zonneveld
Journal:  Neuroradiology       Date:  1983       Impact factor: 2.804

  10 in total
  2 in total

Review 1.  Temporal bone anatomy: correlation of multiplanar reconstruction sections and three-dimensional computed tomography images.

Authors:  Naoko Fujii; Yoshitaka Inui; Kazuhiro Katada
Journal:  Jpn J Radiol       Date:  2010-11-27       Impact factor: 2.374

2.  An observational, prospective study to evaluate the preoperative planning tool "CI-Wizard" for cochlear implant surgery.

Authors:  Markus Pirlich; Mary Tittmann; Daniela Franz; Andreas Dietz; Mathias Hofer
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-09-02       Impact factor: 2.503

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.