Software correction of scatter coincidence in positron CT.

M Endo, T A Iinuma.   

Abstract

This paper describes a software correction of scatter coincidence in positron CT which is based on an estimation of scatter projections from true projections by an integral transform. Kernels for the integral transform are projected distributions of scatter coincidences for a line source at different positions in a water phantom and are calculated by Klein-Nishina's formula. True projections of any composite object can be determined from measured projections by iterative applications of the integral transform. The correction method was tested in computer simulations and phantom experiments with Positologica. The results showed that effects of scatter coincidence are not negligible in the quantitation of images, but the correction reduces them significantly.

Entities:  

Mesh:

Year:  1984        PMID: 6333983     DOI: 10.1007/bf00295572

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  Emission computed tomography.

Authors:  M E Phelps
Journal:  Semin Nucl Med       Date:  1977-10       Impact factor: 4.446

2.  Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction.

Authors:  S C Huang; E J Hoffman; M E Phelps; D E Kuhl
Journal:  J Comput Assist Tomogr       Date:  1979-12       Impact factor: 1.826

3.  Quantitation in positron emission computed tomography: 1. Effect of object size.

Authors:  E J Hoffman; S C Huang; M E Phelps
Journal:  J Comput Assist Tomogr       Date:  1979-06       Impact factor: 1.826

4.  Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections.

Authors:  M Bergström; L Eriksson; C Bohm; G Blomqvist; J Litton
Journal:  J Comput Assist Tomogr       Date:  1983-02       Impact factor: 1.826

5.  Quantitation in positron emission computed tomography: 4. Effect of accidental coincidences.

Authors:  E J Hoffman; S C Huang; M E Phelps; D E Kuhl
Journal:  J Comput Assist Tomogr       Date:  1981-06       Impact factor: 1.826

6.  Analytical study of the performance of a multilayer positron computed tomography scanner.

Authors:  E Tanaka; N Nohara; T Tomitani; M Endo
Journal:  J Comput Assist Tomogr       Date:  1982-04       Impact factor: 1.826

7.  Effect of correction function on image characteristics of Positologica: a positron CT device for the head.

Authors:  M Endo; T A Iinuma; E Tanaka; Y Tateno
Journal:  Eur J Nucl Med       Date:  1982
  7 in total
  1 in total

1.  Assessment of the scatter fraction evaluation methodology using Monte Carlo simulation techniques.

Authors:  D Acchiappati; N Cerullo; R Guzzardi
Journal:  Eur J Nucl Med       Date:  1989
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.