Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction.

S C Huang, E J Hoffman, M E Phelps, D E Kuhl.   

Abstract

Effects of inaccurate attenuation correction on quantitation in positron emission computed tomography were investigated by both computer simulation and theoretical analysis, followed by experimental verification with phantom measurements. It was found that, due to the finite width of detector responses, compensation of scan measurements by measured attenuation correction factors does not completely correct for attenuation. For FWHM greater than 1.8 cm, errors in object size and in activity levels of reconstructed images are more than 4%. Mismatches between true and assumed attenuation media are found to give large errors. These mismatches include object shift, incorrect size and shape, uniform and nonuniform mismatches in attenuation coefficients, and nonzero background levels. Errors as large as 14% in the reconstructed activity level can be introduced by a 5 mm shift in object position. A 5% error in the cylinder diameter can give differences between the total reconstructed activity and true value more than 12%. Strong image distortions, which could lead to incorrect interpretations of images are created by object shift and by nonuniform mismatches in attenuation coefficient. It was also found that statistical noise in measured attenuation correction factors can significantly increase noise levels in images, resulting in lower effective total counts for the emission scan. Effective total counts can be estimated as Neff = kNxmNem/(Nem + kNxm), where Nem and Nxm are total counts in emission and transmission scans, and k is a scanner dependent factor, which accounts for configuration differences.

Mesh:

Year:  1979        PMID: 315970

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  36 in total

1.  Attenuation correction for small animal PET tomographs.

Authors:  Patrick L Chow; Fernando R Rannou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

2.  Quantification with a dedicated breast PET/CT scanner.

Authors:  Spencer L Bowen; Andrea Ferrero; Ramsey D Badawi
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

Review 3.  Positron emission tomography/magnetic resonance imaging: the next generation of multimodality imaging?

Authors:  Bernd J Pichler; Hans F Wehrl; Armin Kolb; Martin S Judenhofer
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 4.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

5.  Image quantification with a large area multiwire proportional chamber positron camera (MUP-PET).

Authors:  S R Cherry; P K Marsden; R J Ott; M A Flower; S Webb; J W Babich
Journal:  Eur J Nucl Med       Date:  1989

6.  Quality control procedures in positron tomography.

Authors:  T Spinks; T Jones; J Heather; M Gilardi
Journal:  Eur J Nucl Med       Date:  1989

7.  A hybrid method of attenuation correction for positron emission tomography brain studies.

Authors:  V Bettinardi; M C Gilardi; S Cargnel; G Rizzo; M Teräs; G Striano; F Fazio
Journal:  Eur J Nucl Med       Date:  1994-12

Review 8.  Brain: normal variations and benign findings in fluorodeoxyglucose-PET/computed tomography imaging.

Authors:  Valentina Berti; Lisa Mosconi; Alberto Pupi
Journal:  PET Clin       Date:  2014-04

9.  Movement correction method for human brain PET images: application to quantitative analysis of dynamic 18F-FDDNP scans.

Authors:  Mirwais Wardak; Koon-Pong Wong; Weber Shao; Magnus Dahlbom; Vladimir Kepe; Nagichettiar Satyamurthy; Gary W Small; Jorge R Barrio; Sung-Cheng Huang
Journal:  J Nucl Med       Date:  2010-01-15       Impact factor: 10.057

Review 10.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.