Analytical study of the performance of a multilayer positron computed tomography scanner.

E Tanaka, N Nohara, T Tomitani, M Endo.   

Abstract

The image-forming performance of multilayer positron tomographs for extended sources is evaluated analytically. The analysis is simplified by "rotation transform," by which three-dimensional photon detection problems are solved by two-dimensional treatment. Event rates of singles, unscattered true coincidence, and a single- and double-scattered coincidence are formulated for a uniform cylinder phantom as functions of various design parameters. Angle factors for Compton scattering and other parameters used in the evaluation are presented. Scatter components in projections and their effect on the reconstructed images are also evaluated. The scatter component in the reconstructed image depends critically on the detector ring radius, phantom radius, method of attenuation correction, etc. When the director radius is relatively small (40 or approximately 45 cm in diameter), the scatter/true ratio at the image center of a 20 cm diameter phantom may be larger than the scatter/true ratio in the event rates. Comparison with experimental data obtained with a head positron tomograph, POSITOLOGICA, showed reasonable agreement both in the total coincidence rates and in the scatter components in the images for a cylindrical phantom of 20 cm in diameter.

Entities:  

Mesh:

Year:  1982        PMID: 6978895     DOI: 10.1097/00004728-198204000-00021

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  Scatter fraction: measurement and correction.

Authors:  A M Paans; G Rosenqvist; S Holte; L Eriksson; M Dahlbom; C Bohm
Journal:  Eur J Nucl Med       Date:  1989

2.  Sensitivity and cross calibration.

Authors:  A M Paans; D W Lamotte
Journal:  Eur J Nucl Med       Date:  1989

3.  On estimating the loss of quantification in PET due to finite detector resolution.

Authors:  A N Bice; D F Wong; H N Wagner
Journal:  Eur J Nucl Med       Date:  1987

4.  Software correction of scatter coincidence in positron CT.

Authors:  M Endo; T A Iinuma
Journal:  Eur J Nucl Med       Date:  1984

5.  Efficient 3-D TOF PET reconstruction using view-grouped histo-images: DIRECT-direct image reconstruction for TOF.

Authors:  Samuel Matej; Suleman Surti; Shridhar Jayanthi; Margaret E Daube-Witherspoon; Robert M Lewitt; Joel S Karp
Journal:  IEEE Trans Med Imaging       Date:  2009-01-13       Impact factor: 10.048

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.