Literature DB >> 4092701

Evaluation of the Cobasbact system for rapid antimicrobial susceptibility testing of positive blood culture broths.

W Kamm, J Bille.   

Abstract

The automated Cobasbact system was adapted for direct antimicrobial susceptibility testing of positive blood culture broths and its performance compared with that of the conventional Kirby-Bauer agar disc diffusion method using 278 positive blood samples. Overall, 1746 antibiotic-organism combinations were tested. Full agreement was 86.9% and essential agreement (i.e. including minor discrepancies) was 91.8%. The system would seem to produce acceptable susceptibility results within five hours after detection of a positive blood culture broth.

Mesh:

Substances:

Year:  1985        PMID: 4092701     DOI: 10.1007/BF02013399

Source DB:  PubMed          Journal:  Eur J Clin Microbiol        ISSN: 0722-2211            Impact factor:   3.267


  11 in total

1.  Laboratory evaluation of a rapid, automatic susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; T L Gavan; J C Sherris; A Balows; J M Matsen; L D Sabath; F Schoenknecht; L D Thrupp; J A Washington
Journal:  Antimicrob Agents Chemother       Date:  1975-04       Impact factor: 5.191

2.  Evaluation of a rapid Bauer-Kirby antibiotic susceptibility determination.

Authors:  D F Liberman; R G Robertson
Journal:  Antimicrob Agents Chemother       Date:  1975-03       Impact factor: 5.191

3.  Rapid antimicrobial susceptibility testing of isolates from blood cultures by direct inoculation and early reading of disk diffusion tests.

Authors:  M B Coyle; L A McGonagle; J J Plorde; C R Clausen; F D Schoenknecht
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

4.  Evaluation of the AutoMicrobic system for identification and susceptibility testing of gram-negative bacilli.

Authors:  B F Woolfrey; R T Lally; M N Ederer; C O Quall
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

5.  Evaluation of the Cobasbact automated antimicrobial susceptibility testing system.

Authors:  G Dupuis
Journal:  Eur J Clin Microbiol       Date:  1985-04       Impact factor: 3.267

6.  Comparison of three automated systems for antimicrobial susceptibility testing of gram-negative bacilli.

Authors:  M T Kelly; J M Latimer; L C Balfour
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

7.  Direct identification and susceptibility testing of gram-negative bacilli from BACTEC bottles by use of the MS-2 system with updated bacterial identification software.

Authors:  J R Dipersio; S M Ficorilli; F J Varga
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

8.  Rapid identification and antimicrobial susceptibility testing of gram-negative bacilli from blood cultures by the AutoMicrobic system.

Authors:  D F Moore; S S Hamada; E Marso; W J Martin
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

9.  Evaluation of a direct blood culture disk diffusion antimicrobial susceptibility test.

Authors:  G V Doern; D R Scott; A L Rashad; K S Kim
Journal:  Antimicrob Agents Chemother       Date:  1981-11       Impact factor: 5.191

10.  Evaluation of the MS-2 automated antimicrobial susceptibility testing system: report of a European collaborative study.

Authors:  H H Johnston; J F Acar; G Linzenmeier; A Visconti
Journal:  Eur J Clin Microbiol       Date:  1982-08       Impact factor: 3.267

View more
  5 in total

1.  Evaluation of the Cobas-Bact system for direct and rapid identification and antimicrobial susceptibility testing of gram-negative rods from positive blood culture broths.

Authors:  W Kamm; A Wenger; J Bille
Journal:  J Clin Microbiol       Date:  1989-01       Impact factor: 5.948

2.  Direct antimicrobial susceptibility testing of gram-negative bacilli in blood cultures by an electrochemical method.

Authors:  A H Huang; J J Wu; Y M Weng; H C Ding; T C Chang
Journal:  J Clin Microbiol       Date:  1998-10       Impact factor: 5.948

3.  Comparison of a highly automated 5-h susceptibility testing system, the Cobas-Bact, with two reference methods: Kirby-Bauer disk diffusion and broth microdilution.

Authors:  P R Murray; A C Niles; R L Heeren
Journal:  J Clin Microbiol       Date:  1987-12       Impact factor: 5.948

4.  Cobas-Bact system for identification of members of the family Enterobacteriaceae in 4 h 20 min.

Authors:  A Wenger; L J Tissières; F R Praplan; W R Kamm; J Bille
Journal:  J Clin Microbiol       Date:  1987-01       Impact factor: 5.948

5.  Cobas-IDA system for identification of Enterobacteriaceae within four hours.

Authors:  H Isenrich; J Wüst
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-04       Impact factor: 3.267

  5 in total