Literature DB >> 3540000

Cobas-Bact system for identification of members of the family Enterobacteriaceae in 4 h 20 min.

A Wenger, L J Tissières, F R Praplan, W R Kamm, J Bille.   

Abstract

The Cobas-Bact (Roche Diagnostics, Basel, Switzerland) new rotor for the identification (ID) in 4 h 20 min of 33 members of the family Enterobacteriaceae to genus and species level was evaluated by testing 444 strains of which 398 belonged to common species and 46 belonged to rare species of Enterobacteriaceae. Each strain was identified by the API 20E system (Analytab Products, Plainview, N.Y.), and additional discriminating tests were set up if necessary. Only first-choice ID were considered in this study and were classified either as high-confidence ID (normalized likelihood, greater than or equal to 80%) or as low-confidence ID (normalized likelihood, less than 80%) requiring additional tests for confirmation. The data were analyzed by two versions of Cobas-Bact software. With the first version of the software (SW8446), the overall accuracy of Cobas-Bact was 95.5% (424 correct ID of 444). When restricted to high-confidence ID it rose to 99.4% (350 of 352) for the common species and 96.9% (31 of 32) for the rare species. Only three strains of the high-confidence group were misidentified. Sixty ID were considered unacceptable because of their low confidence. Using the first software version (SW8446) they represented 12% (46 of 398) of the common species (17 typical strains, 10 Shigella species, 10 inactive Escherichia coli strains, and 9 rare biotypes) and 30% (14 of 46) of the rare species. The same data analyzed by the new version (SW8524) of the Cobas-Bact software resulted in an overall accuracy of 93.9% (417 correct ID). The number of high-confidence ID rose to 401, of which 392 (97.7%) were accurate. The decrease in low-confidence ID (43 versus 60) was mainly due to the Shigella species. In conclusion the accuracy of Cobas-Bact identification system was very good when restricted to high-confidence ID. The Cobas-Bact performance for rare species ID was poorer, but the small number of strains tested does not allow definitive conclusions.

Entities:  

Mesh:

Year:  1987        PMID: 3540000      PMCID: PMC265824          DOI: 10.1128/jcm.25.1.61-66.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Identification of bacteria by computer: general aspects and perspectives.

Authors:  S P Lapage; S Bascomb; W R Willcox; M A Curtis
Journal:  J Gen Microbiol       Date:  1973-08

2.  Evaluation of the four-hour rapid 20E system for identification of members of the family Enterobacteriaceae.

Authors:  D Izard; M O Husson; P Vincent; H Leclerc; D Monget; J M Boeufgras
Journal:  J Clin Microbiol       Date:  1984-07       Impact factor: 5.948

3.  Evaluation of the Cobasbact automated antimicrobial susceptibility testing system.

Authors:  G Dupuis
Journal:  Eur J Clin Microbiol       Date:  1985-04       Impact factor: 3.267

4.  Evaluation of the Cobasbact system for rapid antimicrobial susceptibility testing of positive blood culture broths.

Authors:  W Kamm; J Bille
Journal:  Eur J Clin Microbiol       Date:  1985-12       Impact factor: 3.267

5.  Comparative evaluation of the Eiken and API 20E systems and conventional methods for identification of members of the family Enterobacteriaceae.

Authors:  C B Castillo; D A Bruckner
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

  5 in total
  4 in total

1.  Evaluation of the Cobas-Bact system for direct and rapid identification and antimicrobial susceptibility testing of gram-negative rods from positive blood culture broths.

Authors:  W Kamm; A Wenger; J Bille
Journal:  J Clin Microbiol       Date:  1989-01       Impact factor: 5.948

2.  [Uses and advantages of a computer-assisted microbiologic diagnosis and database system for antibiotic therapy in surgery].

Authors:  K Manncke; W Heizmann
Journal:  Langenbecks Arch Chir       Date:  1989

3.  Agreement between visual and automated UniScept API readings.

Authors:  C M O'Hara; D L Rhoden; P B Smith
Journal:  J Clin Microbiol       Date:  1990-03       Impact factor: 5.948

4.  Cobas-IDA system for identification of Enterobacteriaceae within four hours.

Authors:  H Isenrich; J Wüst
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-04       Impact factor: 3.267

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.