Evaluation of the MS-2 automated antimicrobial susceptibility testing system: report of a European collaborative study.

H H Johnston, J F Acar, G Linzenmeier, A Visconti.   

Abstract

The MS-2 is an instrument for rapid automated testing of antimicrobial susceptibility. Its performance was evaluated by comparison with disc diffusion and MIC tests in a collaborative study in four European laboratories. Tests on independently isolated organisms showed the MS-2 to be in essential agreement with conventional methods in 94.8% of tests. A further series of 170 well-defined pathogens for which a reference antibiogram was available were tested by MS-2 and the manual methods in all of the participating laboratories. MS-2 results were in full accord in 90% of tests and in essential agreement in 94%. MS-2 results compared at least as well with the reference values as did either of the manual methods. Initial problems of false susceptibility results with erythromycin and penicillin were resolved by (1) the addition of small amounts of erythromycin which acted as an inducer and (2) by the use of a low content penicillin disc. MS-2 was found to be reliable and needed no attention following loading of the test cuvette cartridges. A print-out of the results was available 2-5 h after inception of the test.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7173184     DOI: 10.1007/bf02019709

Source DB:  PubMed          Journal:  Eur J Clin Microbiol        ISSN: 0722-2211            Impact factor:   3.267


  3 in total

1.  Antibiotic sensitivity testing. Report of an international collaborative study.

Authors:  H M Ericsson; J C Sherris
Journal:  Acta Pathol Microbiol Scand B Microbiol Immunol       Date:  1971

2.  Antibiotic susceptibility testing by a standardized single disk method.

Authors:  A W Bauer; W M Kirby; J C Sherris; M Turck
Journal:  Am J Clin Pathol       Date:  1966-04       Impact factor: 2.493

3.  Clinical laboratory evaluation of the Abbott MS-2 automated antimicrobial susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; J P Anhalt; J A Washington; L R McCarthy; F D Schoenknecht; J C Sherris; H J Spencer
Journal:  J Clin Microbiol       Date:  1980-09       Impact factor: 5.948

  3 in total
  2 in total

1.  Evaluation of the Cobas-Bact system for direct and rapid identification and antimicrobial susceptibility testing of gram-negative rods from positive blood culture broths.

Authors:  W Kamm; A Wenger; J Bille
Journal:  J Clin Microbiol       Date:  1989-01       Impact factor: 5.948

2.  Evaluation of the Cobasbact system for rapid antimicrobial susceptibility testing of positive blood culture broths.

Authors:  W Kamm; J Bille
Journal:  Eur J Clin Microbiol       Date:  1985-12       Impact factor: 3.267

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.