Literature DB >> 4079861

Investigation of basic imaging properties in digital radiography. 6. MTFs of II-TV digital imaging systems.

H Fujita, K Doi, M L Giger.   

Abstract

We devised a new, simple technique for measuring the modulation transfer function (MTF) of a digital imaging system by using an image of an angulated slit. With this technique, the "presampling" analog MTF, which includes the geometric unsharpness, the detector unsharpness, and the unsharpness of the sampling aperture, can be measured even beyond the Nyquist frequency. A single-frame image of a slightly angulated slit was employed in order to obtain Fourier transforms of line spread functions at different alignments. The presampling MTF was determined by averaging the two Fourier transforms which we obtained from two extreme alignments (center and shifted) of the slit relative to the sampling coordinate. The presampling MTFs of our digital subtraction angiographic system were determined in two orthogonal directions for three different image-intensifier modes.

Mesh:

Year:  1985        PMID: 4079861     DOI: 10.1118/1.595653

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Simulation study comparing high-purity germanium and cadmium zinc telluride detectors for breast imaging.

Authors:  D L Campbell; T E Peterson
Journal:  Phys Med Biol       Date:  2014-10-31       Impact factor: 3.609

2.  Image-quality assessment method for digital phase-contrast imaging based on two-dimensional power spectral analysis.

Authors:  Satoru Matsuo; Junji Morishita; Tetsuro Katafuchi; Chika Honda; Hiroshi Fujita
Journal:  Radiol Phys Technol       Date:  2011-11-10

Review 3.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

4.  Effect of readout direction in the edge profile on the modulation transfer function of computed radiographic systems by use of the edge method.

Authors:  Nobukazu Tanaka; Junji Morishita; Norisato Tsuda; Masafumi Ohki
Journal:  Radiol Phys Technol       Date:  2013-06-04

5.  Application of a variable filter for presampled modulation transfer function analysis with the edge method.

Authors:  Ryo Higashide; Katsuhiro Ichikawa; Hiroshi Kunitomo; Kazuya Ohashi
Journal:  Radiol Phys Technol       Date:  2015-06-19

6.  Efficiency of the Human Observer Compared to an Ideal Observer Based on a Generalized NEQ Which Incorporates Scatter and Geometric Unsharpness: Evaluation with a 2AFC Experiment.

Authors:  Iacovos S Kyprianou; Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Brandon D Gallas; Kyle J Myers
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

7.  Evaluation of Non-Uniform Image Quality Caused by Anode Heel Effect in Digital Radiography Using Mutual Information.

Authors:  Ming-Chung Chou
Journal:  Entropy (Basel)       Date:  2021-04-25       Impact factor: 2.524

8.  Effect of beam quality and readout direction in the edge profile on the modulation transfer function of photostimulable phosphor systems via the edge method.

Authors:  Shinya Takarabe; Taku Kuramoto; Yusuke Shibayama; Hiroki Tsuru; Masato Tatsumi; Toyoyuki Kato; Kazutoshi Okamura; Kazunori Yoshiura
Journal:  J Med Imaging (Bellingham)       Date:  2021-07-20
  8 in total