Literature DB >> 4055876

Direction and rate of socket wear in Charnley low-friction arthroplasty.

B M Wroblewski.   

Abstract

Twenty-two high-density polyethylene sockets from Charnley low-friction arthroplasties have been studied. Acrylic casts and shadowgraph techniques were used to measure both the real and radiographic rates of wear; these rates showed a significant correlation. In the sagittal plane, nine of the sockets had worn lateral to a line drawn vertically from the centre of curvature of the socket, 12 had worn medial to that line and only one was worn exactly in the line. In the coronal plane, nine sockets had worn in front of a similar vertical line, two behind that line and 11 had worn exactly in the line. Evidence of impingement of the neck of the stem onto the rim of the socket was found in 14 patients; this is considered to be one of the causes of socket loosening. The obvious solution is to reduce the diameter of the neck of the stem from 12.5 mm to 10 mm; provided that it is made of cold-formed, high nitrogen-content stainless steel, this narrower neck is strong enough not to fracture.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4055876     DOI: 10.1302/0301-620X.67B5.4055876

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses.

Authors:  J L Tipper; E Ingham; J L Hailey; A A Besong; J Fisher; B M Wroblewski; M H Stone
Journal:  J Mater Sci Mater Med       Date:  2000-02       Impact factor: 3.896

Review 2.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Validation of a simple radiographic method to determine variations in pelvic and acetabular cup sagittal plane alignment after total hip arthroplasty.

Authors:  Won Yong Shon; Siddhartha Gupta; Sandeep Biswal; Chang Yong Hur; Nirmal Jajodia; Suk Joo Hong; Jae Sung Myung
Journal:  Skeletal Radiol       Date:  2008-08-07       Impact factor: 2.199

4.  Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.

Authors:  Colin E Poole; Shantanu S Patil; Darryl D D'Lima; Clifford W Colwell
Journal:  HSS J       Date:  2005-09

5.  Effects of episodic subluxation events on third body ingress and embedment in the THA bearing surface.

Authors:  Anneliese D Heiner; Hannah J Lundberg; Thomas E Baer; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2008-06-17       Impact factor: 2.712

6.  Structural changes in the socket of a Charnley low friction arthroplasty associated with recurrent subluxation.

Authors:  B M Wroblewski; J P Hodgkinson; B Maltby
Journal:  Int Orthop       Date:  1989       Impact factor: 3.075

7.  Long-term results of Charnley low friction arthroplasty in patients younger than 40.

Authors:  B Chamberiin; L Kerboull; M Kerboull
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

Review 8.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

9.  Factors influencing survival of the socket after primary low-friction arthroplasty of the hip.

Authors:  S Kobayashi; K Terayama
Journal:  Arch Orthop Trauma Surg       Date:  1993       Impact factor: 3.067

10.  Clinical biomechanics of wear in total hip arthroplasty.

Authors:  John J Callaghan; Douglas R Pedersen; Richard C Johnston; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2003
View more