Literature DB >> 8457411

Factors influencing survival of the socket after primary low-friction arthroplasty of the hip.

S Kobayashi1, K Terayama.   

Abstract

Two hundred and sixty-seven consecutive primary low-friction arthroplasties, followed for 5 to 18 years after surgery, were studied to assess the factors influencing survival of the socket, using the Kaplan-Meier method. The end point of survival was defined radiologically in two ways: incipient failure (migration of 3 mm or more or rotation of 4 degrees or more) and definite failure (progressive change of position). Twenty-four sockets (9.0%) developed incipient failure, and 14 of them progressed to definite failure. Preservation of the subchondral bone plate or eburnated bone in the acetabular roof, multiple 6-mm anchor holes, and two steps of evolution in socket design (the advent of a pressure-injection socket and than an ogee-flanged socket) benefited socket survival. Polyethylene wear was considered to be the most important factor limiting longevity of the socket.

Entities:  

Mesh:

Year:  1993        PMID: 8457411     DOI: 10.1007/bf00420254

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  17 in total

1.  The first 32 years of total hip arthroplasty. One surgeon's perspective.

Authors:  W H Harris
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

2.  Influence of pelvic position on radiographic measurements of the prosthetic acetabular component. An experimental study on a pelvic model.

Authors:  B Thorén; B Sahlstedt
Journal:  Acta Radiol       Date:  1990-03       Impact factor: 1.990

3.  Measurement of acetabular erosion. The effect of pelvic rotation on common landmarks.

Authors:  R G Wetherell; A A Amis; F W Heatley
Journal:  J Bone Joint Surg Br       Date:  1989-05

4.  How definition of "loosening" affects the incidence of loose total hip reconstructions.

Authors:  R A Brand; D R Pedersen; S A Yoder
Journal:  Clin Orthop Relat Res       Date:  1986-09       Impact factor: 4.176

5.  Socket design and cement pressurisation in the Charnley low-friction arthroplasty.

Authors:  P Shelley; B M Wroblewski
Journal:  J Bone Joint Surg Br       Date:  1988-05

6.  Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem.

Authors:  J R Loudon; J Charnley
Journal:  J Bone Joint Surg Br       Date:  1980-11

7.  Total hip acetabular cup flange design and its effect on cement fixation.

Authors:  I Oh; T W Sander; R W Treharne
Journal:  Clin Orthop Relat Res       Date:  1985-05       Impact factor: 4.176

8.  15-21-year results of the Charnley low-friction arthroplasty.

Authors:  B M Wroblewski
Journal:  Clin Orthop Relat Res       Date:  1986-10       Impact factor: 4.176

9.  Long-term results of low-friction arthroplasty performed in a community hospital, including a radiologic review.

Authors:  H W Hamilton; M Joyce
Journal:  Clin Orthop Relat Res       Date:  1986-10       Impact factor: 4.176

10.  Socket wear in Charnley low friction arthroplasty of the hip.

Authors:  M J Griffith; M K Seidenstein; D Williams; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1978 Nov-Dec       Impact factor: 4.176

View more
  1 in total

1.  The effect of bone porosity on the shear strength of the bone-cement interface.

Authors:  Rouin Amirfeyz; Gordon Bannister
Journal:  Int Orthop       Date:  2008-04-24       Impact factor: 3.075

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.