Accuracy of radiation field alignment in clinical practice.

I Rabinowitz, J Broomberg, M Goitein, K McCarthy, J Leong.   

Abstract

We present an analysis of simulator and portal films of 71 patients. Twenty-five were analyzed retrospectively, 39 prospectively, but without changing routine filming practice, and 7 had daily portal films taken. Treatment-to-treatment variations in anatomy with respect to the field were determined by comparing sequential portal films. The standard deviation of the variations was approximately normally distributed with an average value of 3 mm independent of site and field shaping technique. Discrepancies between the portal and simulator films were greater and depended on the site of treatment. The mean worst-case discrepancy averaged over all sites was 7.7 mm; the lowest value was 3.5 mm in the head and neck region; the highest value was 9.2 mm in the thorax.

Entities:  

Mesh:

Year:  1985        PMID: 4044349     DOI: 10.1016/0360-3016(85)90046-x

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  12 in total

1.  [Monitor assessment of digitalized and post-processed portal films compared to conventional films presented on a light box].

Authors:  S Wachter; N Gerstner; A Colotto; A Battmann; A Gahleitner; U Haverkamp; R Pötter
Journal:  Strahlenther Onkol       Date:  1998-11       Impact factor: 3.621

2.  Imaging luminescent tattoo inks for direct visualization of linac and cobalt irradiation.

Authors:  Ethan P M LaRochelle; Jennifer Soter; Leonardo Barrios; Marysia Guzmán; Samuel S Streeter; Jason R Gunn; Suyapa Bejarano; Brian W Pogue
Journal:  Med Phys       Date:  2020-03-05       Impact factor: 4.071

3.  [Which factors modify the reproducibility of patient positioning in the daily irradiation routine?].

Authors:  C Thilmann; I A Adamietz; S Mose; F Saran; A Buchner; H D Böttcher
Journal:  Strahlenther Onkol       Date:  1997-08       Impact factor: 3.621

4.  Accuracy of an automatic patient-positioning system based on the correlation of two edge images in radiotherapy.

Authors:  Myonggeun Yoon; Minho Cheong; Jinsung Kim; Dong Ho Shin; Sung Yong Park; Se Byeong Lee
Journal:  J Digit Imaging       Date:  2010-02-02       Impact factor: 4.056

5.  [Noninvasive head fixation for external irradiation of tumors of the head-neck area].

Authors:  R J Bale; R Sweeney; M Vogele; M Nevinny; T Auer; A Bluhm; W F Thumfart; P Lukas
Journal:  Strahlenther Onkol       Date:  1998-07       Impact factor: 3.621

6.  Immediate breast reconstruction-impact on radiation management.

Authors:  Ravi A Shankar; J Rao Nibhanupudy; Rajagopalan Sridhar; Cori Ashton; Alfred L Goldson
Journal:  J Natl Med Assoc       Date:  2003-04       Impact factor: 1.798

7.  Reproducibility of irregular radiation fields for malignant lymphoma.

Authors:  U Mock; K Dieckmann; A M Molitor; U Haverkamp; R Pötter
Journal:  Strahlenther Onkol       Date:  1998-10       Impact factor: 3.621

8.  Patient-specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy.

Authors:  Michael H Wittmer; Thomas M Pisansky; Jon J Kruse; Michael G Herman
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

9.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

10.  Improvement of therapeutic index for brain tumors with daily image guidance.

Authors:  Lisa Be Shields; James M Coons; Catherine Dedich; Maria Ragains; Kristi Scalf; Todd W Vitaz; Aaron C Spalding
Journal:  Radiat Oncol       Date:  2013-12-02       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.