Literature DB >> 9810321

Reproducibility of irregular radiation fields for malignant lymphoma.

U Mock1, K Dieckmann, A M Molitor, U Haverkamp, R Pötter.   

Abstract

PURPOSE: Radiation treatment for malignant lymphoma requires large field irradiation with irregular blocks according to the individual anatomy and tumor configuration. For determination of safety margins (PTV) we quantitatively analysed the accuracy of field and block placement with regard to different anatomical regions. PATIENTS AND METHODS: Forty patients with malignant lymphoma were irradiated using the classical supra-/infradiaphragmatic field arrangements. Treatment was performed with 10-MeV photons and irregularly shaped, large opposing fields. We evaluated the accuracy of field and block placements during the treatment courses by comparing the regularly performed verification-with the simulation films. Deviations were determined with respect to the field edges and the central axis, along the x- and z-axis.
RESULTS: With regard to the field edges, mean deviations of 2.0 mm and 3.4 mm were found along the x- and z-axis. The corresponding standard deviations were 3.4 mm and 5.5 mm, respectively. With regard to the shielding blocks, mean displacement along the x- and z-axis was 2.2 mm and 3.8 mm. In addition, overall standard deviations of 5.7 mm (x-axis) and 7.1 mm (z-axis) were determined. During the course of time an improved accuracy of block placement was notable.
CONCLUSION: Systematic analysis of port films gives information for a better defining safety margins in external radiotherapy. Evaluation of verification films on a regular basis improves set-up accuracy by reducing displacements.

Entities:  

Mesh:

Year:  1998        PMID: 9810321     DOI: 10.1007/bf03038986

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  22 in total

1.  [Radiotherapy of follicle center lymphoma. Results of a German multicenter and prospective study. Members of the Study Group "NHL-early stages"].

Authors:  H Sack; A Hoederath; M Stuschke; W Bohndorf; H B Makoski; R P Müller; R Pötter
Journal:  Strahlenther Onkol       Date:  1998-04       Impact factor: 3.621

2.  Localization errors in mantle-field irradiation for Hodgkin's disease.

Authors:  M Hulshof; L Vanuytsel; W Van den Bogaert; E van der Schueren
Journal:  Int J Radiat Oncol Biol Phys       Date:  1989-09       Impact factor: 7.038

3.  [The question of the possibility to reproduce field positions in high-voltage therapy (author's transl)].

Authors:  J Roth; R Sauer; H Hartweg
Journal:  Strahlentherapie       Date:  1978-03

4.  Quality assurance in radiation therapy: systematic evaluation of errors during the treatment execution.

Authors:  S Blanco; M A López-Bote; M Desco
Journal:  Radiother Oncol       Date:  1987-03       Impact factor: 6.280

5.  Radiation therapy in the treatment of Hodgkin's disease.

Authors:  R T Hoppe
Journal:  Semin Oncol       Date:  1980-06       Impact factor: 4.929

6.  Accuracy of field alignment in radiotherapy of head and neck cancer utilizing individualized face mask immobilization: a retrospective analysis of clinical practice.

Authors:  C F Hess; R D Kortmann; R Jany; A Hamberger; M Bamberg
Journal:  Radiother Oncol       Date:  1995-01       Impact factor: 6.280

7.  Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields.

Authors:  J E Marks; A G Haus; H G Sutton; M L Griem
Journal:  Cancer       Date:  1974-07       Impact factor: 6.860

8.  Accuracy in mantle field irradiations: irradiated volume and daily dose.

Authors:  C Weltens; G Leunens; A Dutreix; J M Cosset; F Eschwege; E van der Schueren
Journal:  Radiother Oncol       Date:  1993-10       Impact factor: 6.280

9.  Patterns of care study: Hodgkin's disease relapse rates and adequacy of portals.

Authors:  J J Kinzie; G E Hanks; C J MacLean; S Kramer
Journal:  Cancer       Date:  1983-12-15       Impact factor: 6.860

10.  Progress in the treatment of Hodgkin's disease in the United States, 1973 versus 1983. The Patterns of Care Study.

Authors:  R T Hoppe; A L Hanlon; G E Hanks; J B Owen
Journal:  Cancer       Date:  1994-12-15       Impact factor: 6.860

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.