[Monitor assessment of digitalized and post-processed portal films compared to conventional films presented on a light box].

S Wachter1, N Gerstner, A Colotto, A Battmann, A Gahleitner, U Haverkamp, R Pötter.   

Abstract

PURPOSE: Judgement of image quality and detail recognition of digitized and post-processed portal films presented on a computer monitor compared to the present standard, conventional portal films presented on a light box.
MATERIALS AND METHODS: Conventional portal films of 3 different tumor sites (10 pelvis, 10 cranium, 10 vertebral column) were presented to a panel of 8 observers in 3 different matters: conventional film presented on a light box (Conv), digitized post-processed images (Dig-1) and digitized post-processed images (Dig-2) presented on a high resolution computer monitor. Subjective judgement of image quality, detailed recognition and time requirement of conventional films compared to monitor presentation were evaluated using a 5-scaled questionnaire (from 1 = much better to 5 = much worse). Furthermore the observers had to point out predefined anatomical bony structure on the conventional films (Conv) as well as on the digitized post-processed images (Dig-2). Standard deviations of the landmark outlined by 10 different observers were used as a criterion of objective detail recognition (Figure 1).
RESULTS: Image quality of digitized post-processed images presented on the computer monitor was judged statistical significant better than that of conventional films (pelvis 78%, vertebral column 62%, cranium 45% better) (Figure 3). Similar results were found for comparison of detail recognition: digitized post-processed images were scored better for pelvis in 81%, for vertebral column in 57%, for cranium in 40% (Figure 4, Table 1). Most benefit from portal film enhancement was found for pelvic images, where portal films are known to be of poor image quality (Figure 2). In contrast image quality of non-processed digital images compared to conventional films was graded worse (pelvis 69%, vertebral column 53%, cranium 71% worse) (Figure 4). Digital post-processed images were especially for the pelvis judged to require less time (pelvis 68%, vertebral column 26%, cranium 8% less time requirement) (figure 5). For the pelvis a statistical significant decrease of standard deviations was found for Dig-2 compared to conventional films, indicating an objective increase of image quality and detailed recognition (Table 2). In case of vertebral column and cranium no significant differences were evaluated (Table 3).
CONCLUSIONS: Digitized enhanced portal films presented on a computer monitor resulted in a quicker assessment and equal to better image quality as well as detail recognition compared to conventional films. Non-processed digitized images were judged to be of less image quality.

Entities:  

Mesh:

Year:  1998        PMID: 9830441     DOI: 10.1007/bf03038297

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  21 in total

1.  [Preliminary results with digital luminescence radiography in radiotherapy].

Authors:  S Reichelt; M Prokop; J W Oestmann; R M Schulte; K H Renner; M Galanski
Journal:  Strahlenther Onkol       Date:  1990-07       Impact factor: 3.621

2.  The design of megavoltage projection imaging systems: some theoretical aspects.

Authors:  W Swindell; E J Morton; P M Evans; D G Lewis
Journal:  Med Phys       Date:  1991 Sep-Oct       Impact factor: 4.071

3.  A method for the measurement of field placement errors in digital portal images.

Authors:  H Meertens; J Bijhold; J Strackee
Journal:  Phys Med Biol       Date:  1990-03       Impact factor: 3.609

4.  Automatic digital contrast enhancement of radiotherapy films.

Authors:  G W Sherouse; J Rosenman; H L McMurry; S M Pizer; E L Chaney
Journal:  Int J Radiat Oncol Biol Phys       Date:  1987-05       Impact factor: 7.038

5.  Contrast enhancement of portal images by selective histogram equalization.

Authors:  I Crooks; B G Fallone
Journal:  Med Phys       Date:  1993 Jan-Feb       Impact factor: 4.071

6.  Portal film enhancement: technique and clinical utility.

Authors:  J Rosenman; C A Roe; R Cromartie; K E Muller; S M Pizer
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-01-15       Impact factor: 7.038

Review 7.  [Networks for image communication. Current status].

Authors:  D Meyer-Ebrecht
Journal:  Radiologe       Date:  1994-06       Impact factor: 0.635

8.  A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system.

Authors:  J Gildersleve; D P Dearnaley; P M Evans; M Law; C Rawlings; W Swindell
Journal:  Radiother Oncol       Date:  1994-05       Impact factor: 6.280

9.  Objective decision-making following a portal film: the results of a pilot study.

Authors:  J W Denham; M J Dally; K Hunter; J Wheat; P P Fahey; C S Hamilton
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-08-01       Impact factor: 7.038

10.  On-line measurement of field placement errors in external beam radiotherapy.

Authors:  W C Lam; M Partowmah; D J Lee; M D Wharam; K S Lam
Journal:  Br J Radiol       Date:  1987-04       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.