Literature DB >> 9689955

[Noninvasive head fixation for external irradiation of tumors of the head-neck area].

R J Bale1, R Sweeney, M Vogele, M Nevinny, T Auer, A Bluhm, W F Thumfart, P Lukas.   

Abstract

PURPOSE: To fully utilize the technical capabilities of radiation diagnostics and planning, a precise and reproducible method of head fixation is a prerequisite.
METHOD: We have adapted the Vogele-Bale-Hohner (VBH) head holder (Wellhöfer Dosimetrie, Schwarzenbruck, Germany), originally designed for frameless stereotactic operations, to the requirements of external beam radiotherapy. A precise and reproducible head fixation is attained by an individualized vacuum upper-dental cast which is connected over 2 hydraulic arms to an adjustable head- and rigid base-plate. Radiation field and patient alignment lasers are marked on a relocatable clear PVC localization box.
RESULTS: The possibility of craniocaudal adjustment of the head plate on the base plate allows the system to adapt to the actual position of the patient on the radiotherapy couch granting tensionless repositioning. The VBH head holder has proven itself to be a precise yet practicable method of head fixation. Duration of mouthpiece production and daily repositioning is comparable to that of the thermoplastic mask.
CONCLUSION: The new head holder is in routine use at our hospital and quite suitable for external beam radiation of patients with tumors of the head and neck.

Entities:  

Mesh:

Year:  1998        PMID: 9689955     DOI: 10.1007/bf03038348

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  16 in total

1.  The Stanford "bite-block", a head-immobilization accessory.

Authors:  C J Karzmark; M A Bagshaw; W G Faraghan; J Lawson
Journal:  Br J Radiol       Date:  1975-11       Impact factor: 3.039

2.  Relocatable frame for stereotactic external beam radiotherapy.

Authors:  S S Gill; D G Thomas; A P Warrington; M Brada
Journal:  Int J Radiat Oncol Biol Phys       Date:  1991-03       Impact factor: 7.038

3.  Plastic molds for patient immobilization.

Authors:  C Devereux; G Grundy; P Littman
Journal:  Int J Radiat Oncol Biol Phys       Date:  1976 Mar-Apr       Impact factor: 7.038

4.  Repositioning accuracy: comparison of a noninvasive head holder with thermoplastic mask for fractionated radiotherapy and a case report.

Authors:  R Sweeney; R Bale; M Vogele; M Nevinny-Stickel; A Bluhm; T Auer; G Hessenberger; P Lukas
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-05-01       Impact factor: 7.038

5.  [Face masks for radiotherapy of head and neck tumors: comparative tests of different materials].

Authors:  M Niewald; W Lehmann; B Scharding; W Berberich; K Schnabel; H K Leetz
Journal:  Strahlenther Onkol       Date:  1986-07       Impact factor: 3.621

6.  [Fixation of patients during irradiation of the neurocranium and visceral cranium].

Authors:  W Bohndorf; E Richter
Journal:  Strahlentherapie       Date:  1983-12

7.  [The individual irradiation mask--a means for improving focussing accuracy].

Authors:  H J Thiel; M Wuermeling; M Herbst
Journal:  Strahlentherapie       Date:  1983-03

8.  Accuracy in radiation field alignment in head and neck cancer: a prospective study.

Authors:  H Huizenga; P C Levendag; P M De Porre; A G Visser
Journal:  Radiother Oncol       Date:  1988-02       Impact factor: 6.280

9.  Feasibility of patient immobilization for conventional cranial irradiation with a relocatable stereotactic frame.

Authors:  R W Laing; V Thompson; A P Warrington; M Brada
Journal:  Br J Radiol       Date:  1993-11       Impact factor: 3.039

10.  An adapter for computed tomography-guided stereotaxis.

Authors:  L V Laitinen; B Liliequist; M Fagerlund; A T Eriksson
Journal:  Surg Neurol       Date:  1985-06
View more
  1 in total

1.  [First experiences with computer-assisted frameless stereotactic interstitial brachytherapy (CASIB)].

Authors:  R J Bale; W Freysinger; A Martin; M Vogele; T Auer; P Eichberger; E Hensler; A Sztankay; T Auberger; A R Gunkel; W F Thumfart; P Lukas
Journal:  Strahlenther Onkol       Date:  1998-09       Impact factor: 3.621

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.