Literature DB >> 4041414

The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis.

E S Perkins.   

Abstract

The ocular pulse and applanation tension were measured with a recording applanation tonometer in 38 patients suspected of having internal carotid artery stenosis. Abnormalities of the ocular pulse amplitude, intraocular pressure, or combinations of these two measurements were found in 23 (82%) of 28 patients who were subsequently found to have angiographic evidence of 50% or more stenosis of one or both internal carotid arteries. Of 10 patients without angiographic evidence of carotid stenosis the ocular pulse amplitude, intraocular pressure, or both were abnormal in five, but two patients had an ocular cause for abnormality and two of the remaining three had evidence of carotid disease in the form of atheromatous plaques. These results suggest that measurement of the amplitude of the ocular pulse in addition to the intraocular pressure can predict the presence of carotid artery stenosis and indicate the need for further investigation. If a tonometer capable of measuring the pulse amplitude was used routinely in ophthalmic examinations, it would provide a useful screening test for the early diagnosis and treatment of carotid artery disease and might thereby reduce the frequency of strokes.

Entities:  

Mesh:

Year:  1985        PMID: 4041414      PMCID: PMC1040710          DOI: 10.1136/bjo.69.9.676

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  8 in total

1.  Ocular pressure studies in the diagnosis of carotid artery disease.

Authors:  D L Knox
Journal:  Trans Am Ophthalmol Soc       Date:  1973

2.  Noncontact detection of ocular pulse--correlation with carotid stenosis.

Authors:  J L Zuckerman; K D Taylor; H J Grossman
Journal:  Invest Ophthalmol Vis Sci       Date:  1977-11       Impact factor: 4.799

3.  A new recording tonometer.

Authors:  F S Perkins; J Edwards; R C Saxena
Journal:  Trans Ophthalmol Soc U K       Date:  1977-09

4.  The ocular pulse.

Authors:  E S Perkins
Journal:  Curr Eye Res       Date:  1981       Impact factor: 2.424

5.  Ocular pulse in high myopia: a study of 40 eyes.

Authors:  K F To'mey; B M Faris; A E Jalkh; A M Nasr
Journal:  Ann Ophthalmol       Date:  1981-05

6.  Evaluation of internal carotid stenosis with the Chronopulse, an automated ocular pulse arrival time recorder.

Authors:  J D Baker; M Kaufman; H I Machleder
Journal:  Am J Surg       Date:  1981-08       Impact factor: 2.565

7.  A prospective evaluation of indirect methods for detecting carotid atherosclerosis.

Authors:  G E Bone; D Dickinson; M J Pomajzl
Journal:  Surg Gynecol Obstet       Date:  1981-05

8.  Carotid occlusive disease: effect of complete occlusion of internal carotid artery on intraocular pulse/pressure relation and on ophthalmic arterial pressure.

Authors:  M E Langham; K F To'mey; T J Preziosi
Journal:  Stroke       Date:  1981 Nov-Dec       Impact factor: 7.914

  8 in total
  10 in total

Review 1.  [Tonometry in change. From indentation and applanation to contour adaptation].

Authors:  H Kanngiesser; C Kniestedt
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

Review 2.  [Dynamic contour tonometry].

Authors:  C Kniestedt; H E Kanngiesser
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

3.  Factors influencing the ocular pulse--axial length.

Authors:  C B James; D R Trew; K Clark; S E Smith
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

4.  The ocular pulse.

Authors:  V J Marmion
Journal:  Br J Ophthalmol       Date:  1991-09       Impact factor: 4.638

5.  The ocular pulse.

Authors:  R Hitchings
Journal:  Br J Ophthalmol       Date:  1991-02       Impact factor: 4.638

6.  [Ocular pulse amplitude: a new biometrical parameter for the diagnose of glaucoma?].

Authors:  T Romppainen; C Kniestedt; L M Bachmann; J Stürmer
Journal:  Ophthalmologe       Date:  2007-03       Impact factor: 1.059

7.  Postural studies in pulsatile ocular blood flow: I. Ocular hypertension and normotension.

Authors:  D R Trew; S E Smith
Journal:  Br J Ophthalmol       Date:  1991-02       Impact factor: 4.638

8.  Pulsatile tissue deformation dynamics of the murine retina and choroid mapped by 4D optical coherence tomography.

Authors:  Bernhard Baumann; Conrad W Merkle; Marco Augustin; Martin Glösmann; Gerhard Garhöfer
Journal:  Biomed Opt Express       Date:  2022-01-07       Impact factor: 3.732

9.  Choroidal Blood Flow Change in Eyes with High Myopia.

Authors:  Young Seong Yang; Jae Woong Koh
Journal:  Korean J Ophthalmol       Date:  2015-09-22

10.  Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?

Authors:  T Bertelmann; S Langanke; M Potstawa; I Strempel
Journal:  Clin Ophthalmol       Date:  2014-07-14
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.