Signal-to-noise properties of mammographic film-screen systems.

R M Nishikawa, M J Yaffe.   

Abstract

The signal-to-noise ratio (SNR) and the detective quantum efficiency (DQE) have been experimentally determined as a function of spatial frequency for several mammographic film-screen systems. These two parameters were determined from our measurements of noise power spectra and sensitometric properties of each system along with modulation transfer function (MTF) data for the screens which were obtained from others. From the noise power spectra, it was found that film noise contributes significantly to the total noise of mammographic film-screen systems, comprising 30%-50% of the total noise at 1 cycle/mm and as much as 75% at 5 cycles/mm. All systems had approximately the same SNR below 1.5 cycles/mm, but differed at higher frequencies due to differences in screen MTF and in the gradient of the film's sensitometric curve. The DQE curves varied between systems at all frequencies, however, due to differences in system speed, MTF, and gradient. Generally, the DQE of mammographic film-screen systems is between 10%-30% at frequencies below 1 cycle/mm and decreases to about 1% between 8 and 12 cycles/mm. Compared to film-screen systems used in general radiography, mammographic systems have similar DQE values at low frequencies, but are superior at higher frequencies.

Mesh:

Year:  1985        PMID: 3974523     DOI: 10.1118/1.595781

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; D Albagli; S Han; E J Tkaczyk; C E Landberg; B Opsahl-Ong; P R Granfors; I Levis; C J D'Orsi; R E Hendrick
Journal:  Med Phys       Date:  2000-03       Impact factor: 4.071

2.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Noise power properties of a cone-beam CT system for breast cancer detection.

Authors:  Kai Yang; Alexander L C Kwan; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  ACR-AAPM-SIIM practice guideline for determinants of image quality in digital mammography.

Authors:  Kalpana M Kanal; Elizabeth Krupinski; Eric A Berns; William R Geiser; Andrew Karellas; Martha B Mainiero; Melissa C Martin; Samir B Patel; Daniel L Rubin; Jon D Shepard; Eliot L Siegel; Judith A Wolfman; Tariq A Mian; Mary C Mahoney
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

Review 5.  Research in digital mammography and tomosynthesis at the University of Toronto.

Authors:  Martin J Yaffe
Journal:  Radiol Phys Technol       Date:  2014-06-25

6.  Image quality control for digital mammographic systems: initial experience and outlook.

Authors:  H Roehrig; T Yu; E Krupinski
Journal:  J Digit Imaging       Date:  1995-05       Impact factor: 4.056

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.