Literature DB >> 3966349

The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output.

A J Labovitz, T A Buckingham, K Habermehl, J Nelson, H L Kennedy, G A Williams.   

Abstract

Cardiac output was measured by two-dimensional echocardiographic Doppler technique in 55 adult patients in the intensive care unit. Doppler cardiac output determinations were measured from four sites (suprasternal long axis of the ascending aorta, suprasternal long axis of the descending aortic, apical left ventricular outflow tract, and parasternal long axis of the main pulmonary artery) and were compared to cardiac output determined by thermodilution for a total of 101 observations (r = 0.84). Mean cardiac output was 5.3 L/min (range 1.8 to 9.5 L/min) by Doppler technique and 5.1 L/min (range 1.6 to 8.9 L/min) as measured by thermodilution. Correlation of Doppler cardiac output with thermodilution cardiac output gave r values of 0.85, 0.83, 0.90, and 0.81 from the ascending aorta, descending aorta, left ventricular outflow tract, and pulmonary artery, respectively. Averaging of data in patients in whom more than one determination was possible resulted in improved correlation (r = 0.94). Thus, cardiac output can be measured with reasonable accuracy by Doppler from a variety of sampling sites and averaging of data from more than one site may improve these results.

Entities:  

Mesh:

Year:  1985        PMID: 3966349     DOI: 10.1016/0002-8703(85)90602-7

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  12 in total

1.  Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model.

Authors:  K Dennig; H J Nesser; D Hall; H U Haase; A Schömig
Journal:  Heart       Date:  1998-04       Impact factor: 5.994

2.  Doppler measurement of cardiac output across prosthetic mitral valves.

Authors:  H Dittmann; W Voelker; K R Karsch; L Seipel
Journal:  Klin Wochenschr       Date:  1990-03-05

3.  Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.

Authors:  D B Northridge; I N Findlay; J Wilson; E Henderson; H J Dargie
Journal:  Br Heart J       Date:  1990-02

4.  Assessment of cardiac function in infants with transposition of the great arteries after surgery: comparison of two methods.

Authors:  Fan Yang; Roberta Iacobelli; Jian-Ming Wang; Fiore Salvatore Iorio
Journal:  World J Pediatr       Date:  2018-07-30       Impact factor: 2.764

5.  Disturbed synthesis of insulinlike growth factor I and its binding proteins may influence renal function changes in liver cirrhosis.

Authors:  C M Fernández-Rodriguez; I Prada; A Andrade; M Moreiras; R Guitián; R Aller; J L Lledó; G Cacho; J Quiroga; J Prieto
Journal:  Dig Dis Sci       Date:  2001-06       Impact factor: 3.199

Review 6.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

Review 7.  Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: Novel techniques and new advances.

Authors:  D E Warburton; M J Haykowsky; H A Quinney; D P Humen; K K Teo
Journal:  Sports Med       Date:  1999-04       Impact factor: 11.136

8.  Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report.

Authors:  N Nelson; B Janerot-Sjöberg
Journal:  Crit Care       Date:  2001-01-05       Impact factor: 9.097

9.  Validation of the beat to beat measurement of blood velocity in the human ascending aorta by a new high temporal resolution Doppler ultrasound spectral analyser.

Authors:  A J Coats; C Murphy; J Conway; P Sleight
Journal:  Br Heart J       Date:  1992-08

10.  Early diastolic left ventricular inflow pressures in normal subjects and patients with dilated cardiomyopathy. Reconstruction from pulsed Doppler echocardiography.

Authors:  S Fujimoto; K H Parker; H B Xiao; K S Inge; D G Gibson
Journal:  Br Heart J       Date:  1995-10
View more