Literature DB >> 11178225

Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report.

N Nelson1, B Janerot-Sjöberg.   

Abstract

BACKGROUND: The haemodynamic as well as the ventilatory consequences of mechanical ventilation can be harmful in critically ill neonates. Newly developed ventilatory lung protective strategies are not always available immediately and in an acute situation the haemodynamic changes caused by mechanical ventilation can affect the oxygen delivery considerably. We report the case of a male neonate who was treated with conventional pressure-controlled mechanical ventilation because of respiratory distress and progressive respiratory acidosis resulting from meconium aspiration. Because of poor arterial oxygenation despite 100% inspired oxygen and increased ventilator settings, echocardiography was performed to exclude central haemodynamic reasons for low oxygen delivery.
METHOD: Doppler echocardiography was used for the measurement of stroke volume and cardiac output. Pulse oximetry and aortic blood pressure were monitored continuously.
RESULTS: Echocardiography revealed no cardiac malformations or signs of persistent fetal circulation. When inspiratory pressures and duration were increased, beat-to-beat variation in stroke volume preceded decay in cardiac output. Stroke volume variations and oxygen saturation values guided ventilator settings until extracorporal membrane oxygenation could be arranged for. After recovery and discharge 4 weeks later the boy is progressing normally.
CONCLUSION: Because oxygen delivery is dependent on both blood flow and arterial oxygen content, measurement of cardiac output as well as left heart oxygen saturation is a useful guide to optimizing oxygen delivery. This case report demonstrates how Doppler echocardiographic monitoring of beat-to-beat changes in stroke volume can be used to detect early negative haemodynamic effects of increased mechanical ventilation settings before cardiac output is affected.

Entities:  

Mesh:

Year:  2001        PMID: 11178225      PMCID: PMC29056          DOI: 10.1186/cc977

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


  13 in total

1.  Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure.

Authors:  F Michard; S Boussat; D Chemla; N Anguel; A Mercat; Y Lecarpentier; C Richard; M R Pinsky; J L Teboul
Journal:  Am J Respir Crit Care Med       Date:  2000-07       Impact factor: 21.405

2.  Cardiac output determined by ultrasound-Doppler: clinical applications.

Authors:  B J Sjöberg; B Wranne
Journal:  Clin Physiol       Date:  1990-09

3.  Reevaluation of hemodynamic consequences of positive pressure ventilation: emphasis on cyclic right ventricular afterloading by mechanical lung inflation.

Authors:  F Jardin; G Delorme; A Hardy; B Auvert; A Beauchet; J P Bourdarias
Journal:  Anesthesiology       Date:  1990-06       Impact factor: 7.892

4.  Effect of intermittent positive pressure ventilation on diastolic ventricular filling patterns in premature infants.

Authors:  E Maroto; J C Fouron; G Teyssier; H Bard; N H van Doesburg; D Cartwright
Journal:  J Am Coll Cardiol       Date:  1990-07       Impact factor: 24.094

5.  Increasing tidal volumes and pulmonary overdistention adversely affect pulmonary vascular mechanics and cardiac output in a pediatric swine model.

Authors:  I M Cheifetz; D M Craig; G Quick; J J McGovern; M L Cannon; R M Ungerleider; P K Smith; J N Meliones
Journal:  Crit Care Med       Date:  1998-04       Impact factor: 7.598

Review 6.  The hemodynamic consequences of mechanical ventilation: an evolving story.

Authors:  M R Pinsky
Journal:  Intensive Care Med       Date:  1997-05       Impact factor: 17.440

7.  The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output.

Authors:  A J Labovitz; T A Buckingham; K Habermehl; J Nelson; H L Kennedy; G A Williams
Journal:  Am Heart J       Date:  1985-02       Impact factor: 4.749

8.  Cardiac output determination in the neonate.

Authors:  M H Lees
Journal:  J Pediatr       Date:  1983-05       Impact factor: 4.406

9.  Influence of positive end-expiratory pressure on left ventricular performance.

Authors:  F Jardin; J C Farcot; L Boisante; N Curien; A Margairaz; J P Bourdarias
Journal:  N Engl J Med       Date:  1981-02-12       Impact factor: 91.245

10.  Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP.

Authors:  F Michard; D Chemla; C Richard; M Wysocki; M R Pinsky; Y Lecarpentier; J L Teboul
Journal:  Am J Respir Crit Care Med       Date:  1999-03       Impact factor: 21.405

View more
  1 in total

1.  Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

Authors:  S M M Naidu; Prem C Pandey; Uttam R Bagal; Suhas P Hardas
Journal:  Med Biol Eng Comput       Date:  2017-11-18       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.