Literature DB >> 3935662

Leukocyte esterase-nitrite and bioluminescence assays as urine screens.

B M Males, W R Bartholomew, D Amsterdam.   

Abstract

The 1-min leukocyte esterase (LE)-nitrite test (Chemstrip 9; Biodynamics, Division of Boehringer Mannheim Biochemicals, Indianapolis, Ind.) and a bioluminescence assay (Monolight centrifugation method; Analytical Luminescence Laboratory, Inc., San Diego, Calif.) were tested for their efficacy as urine screens among 453 patients at a tertiary-care teaching hospital. Both methods had the capacity to exclude significant bacteriuria (greater than or equal to 10(5) CFU/ml) when compared with the results of conventional culture methods, with predictive values of 99 and 93%, respectively, for a negative test. Bioluminescence was the more accurate nonculture method used. Sensitivity and specificity values were 97 and 71%, respectively, for bioluminescence, 82 and 60%, respectively, for LE with nitrite, and 72 and 64%, respectively, for LE without nitrite. At reduced levels of bacteriuria less than 10(5) CFU/ml), the sensitivities of LE-nitrite and bioluminescence were decreased but comparable. The addition of protein and blood test results in the Chemstrip 9, along with LE-nitrite as bacteriuria indicators, were unsatisfactory because of the large numbers of false-positive results attributed to protein and blood determinations. LE activity as detected by the LE test was a poor predictor of significant bacteriuria in both male and female patients. The sensitivity (71%) and specificity (57%) of the LE test in male patients were significantly lower than those previously reported and varied with the patient population studied.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3935662      PMCID: PMC268461          DOI: 10.1128/jcm.22.4.531-534.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  23 in total

1.  The diagnosis of urinary tract infection.

Authors:  C V PRYLES
Journal:  Pediatrics       Date:  1960-09       Impact factor: 7.124

2.  Leukocyte esterase activity and nitrite test as a rapid screen for significant bacteriuria.

Authors:  R Oneson; D H Gröschel
Journal:  Am J Clin Pathol       Date:  1985-01       Impact factor: 2.493

3.  Improved urine screening using a combination of leukocyte esterase and the Lumac system.

Authors:  M A Pfaller; G Scharnweber; B Stewart; F P Koontz
Journal:  Diagn Microbiol Infect Dis       Date:  1985-05       Impact factor: 2.803

4.  Evaluation of leukocyte esterase activity as a rapid screening technique for bacteriuria.

Authors:  J L Perry; J S Matthews; D E Weesner
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

5.  Firefly luciferase ATP assay as a screening method for bacteriuria.

Authors:  A Thore; A Lundin; S Anséhn
Journal:  J Clin Microbiol       Date:  1983-02       Impact factor: 5.948

6.  Use of leukocyte esterase-nitrate activity as predictive assays of significant bacteriuria.

Authors:  D L Smalley; A N Dittmann
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

7.  Comparison of the Lumac and Monolight systems for detection of bacteriuria by bioluminescence.

Authors:  D L Drow; C H Baum; G Hirschfield
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

8.  Correlation of leukocyte esterase detection and the presence of leukocytes in body fluids.

Authors:  D L Smalley; V R Doyle; J K Duckworth
Journal:  Am J Med Technol       Date:  1982-02

9.  Evaluation of two bioluminescence-measuring instruments, the Turner Design and Lumac systems, for the rapid screening of urine specimens.

Authors:  W D Welch; L Thompson; M Layman; P M Southern
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

10.  Bacteriuria screening by direct bioluminescence assay of ATP.

Authors:  R B Schifman; M Wieden; J Brooker; M Chery; M Delduca; K Norgard; C Palen; N Reis; J Swanson; J White
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

View more
  8 in total

1.  Rapid screening for bacteriuria in pregnancy.

Authors:  W Graninger; D Fleischmann; B Schneeweiss; L Aram; F Stockenhuber
Journal:  Infection       Date:  1992 Jan-Feb       Impact factor: 3.553

2.  FiltraCheck-UTI, a rapid, disposable system for detection of bacteriuria.

Authors:  C C Longoria; G A Gonzalez
Journal:  J Clin Microbiol       Date:  1987-05       Impact factor: 5.948

Review 3.  ACP Best Practice No 167: the laboratory diagnosis of urinary tract infection.

Authors:  J C Graham; A Galloway
Journal:  J Clin Pathol       Date:  2001-12       Impact factor: 3.411

Review 4.  Detection of urinary tract infections by rapid methods.

Authors:  M Pezzlo
Journal:  Clin Microbiol Rev       Date:  1988-07       Impact factor: 26.132

5.  Use of the Bac-T-Screen to predict bacteriuria from urine specimens held at room temperature.

Authors:  D N Wright; B Saxon; J M Matsen
Journal:  J Clin Microbiol       Date:  1986-08       Impact factor: 5.948

6.  A non-contact device for fast screening of wound infections.

Authors:  Jon Senkowsky; Shuxin Li; Ashwin Nair; Suvra Pal; Wenjing Hu; Liping Tang
Journal:  Exp Dermatol       Date:  2021-06-05       Impact factor: 4.511

7.  An Intact Cell Bioluminescence-Based Assay for the Simple and Rapid Diagnosis of Urinary Tract Infection.

Authors:  Sherwin Reyes; Nga Le; Mary Denneth Fuentes; Jonathan Upegui; Emre Dikici; David Broyles; Edward Quinto; Sylvia Daunert; Sapna K Deo
Journal:  Int J Mol Sci       Date:  2020-07-16       Impact factor: 5.923

8.  A capacitive touch screen sensor for detection of urinary tract infections in portable biomedical devices.

Authors:  Carlos Honrado; Tao Dong
Journal:  Sensors (Basel)       Date:  2014-07-30       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.