Literature DB >> 3584428

FiltraCheck-UTI, a rapid, disposable system for detection of bacteriuria.

C C Longoria, G A Gonzalez.   

Abstract

The initial evaluation of the FiltraCheck-UTI bacteriuria detection system is described. The colorimetric test, which utilizes a disposable filter disk and a stable reagent system, does not require instrumentation. The test procedure is simple and may be performed in less than 1 min. Results obtained with the FiltraCheck-UTI system were compared with those obtained by conventional semiquantitative culturing. Of 1,198 urine specimens evaluated, 202 (16.9%) were determined to be significant positives at greater than or equal to 10(5) CFU/ml by the culture method. The sensitivity and specificity of the FiltraCheck-UTI system were 96.5 and 79.7%, respectively, and the negative predictive value was 99.1%. The high sensitivity, rapidity, simplicity, and unique disposable format of the FiltraCheck-UTI system offer significant advantages over other commonly used screening methods.

Mesh:

Year:  1987        PMID: 3584428      PMCID: PMC266120          DOI: 10.1128/jcm.25.5.926-928.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

1.  Bioluminescence screening for bacteriuria.

Authors:  J C Kolbeck; R A Padgett; E G Estevez; L J Harrell
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

2.  Clinical laboratory evaluation of a bacteriuria detection device for urine screening.

Authors:  J R Davis; C E Stager; G F Araj
Journal:  Am J Clin Pathol       Date:  1984-01       Impact factor: 2.493

3.  Evaluation of a two-minute test for urine screening.

Authors:  M T Pezzlo; M A Wetkowski; E M Peterson; L M de la Maza
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

4.  Problems of spectrum and bias in evaluating the efficacy of diagnostic tests.

Authors:  D F Ransohoff; A R Feinstein
Journal:  N Engl J Med       Date:  1978-10-26       Impact factor: 91.245

5.  Clinical evaluation of three rapid methods for the detection of significant bacteriuria.

Authors:  E Bixler-Forell; M A Bertram; D A Bruckner
Journal:  J Clin Microbiol       Date:  1985-07       Impact factor: 5.948

6.  Screening of urine cultures by three automated systems.

Authors:  M T Pezzlo; G L Tan; E M Peterson; L M de la Maza
Journal:  J Clin Microbiol       Date:  1982-03       Impact factor: 5.948

7.  How important is bacteriuria?

Authors:  E H Kass
Journal:  Rev Infect Dis       Date:  1982 Mar-Apr

8.  Diagnosis of coliform infection in acutely dysuric women.

Authors:  W E Stamm; G W Counts; K R Running; S Fihn; M Turck; K K Holmes
Journal:  N Engl J Med       Date:  1982-08-19       Impact factor: 91.245

9.  Colorimetric method for rapid determination of bacteriuria.

Authors:  C Wallis; J L Melnick; C J Longoria
Journal:  J Clin Microbiol       Date:  1981-09       Impact factor: 5.948

10.  Leukocyte esterase-nitrite and bioluminescence assays as urine screens.

Authors:  B M Males; W R Bartholomew; D Amsterdam
Journal:  J Clin Microbiol       Date:  1985-10       Impact factor: 5.948

View more
  5 in total

Review 1.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

2.  Asymptomatic bacteriuria during pregnancy.

Authors:  K Bertakis
Journal:  West J Med       Date:  1989-02

3.  Evaluation of the modified Bac-T-Screen and FiltraCheck-UTI urine screening systems for detection of clinically significant bacteriuria.

Authors:  P R Murray; A C Niles; R L Heeren; F Pikul
Journal:  J Clin Microbiol       Date:  1988-11       Impact factor: 5.948

Review 4.  Detection of urinary tract infections by rapid methods.

Authors:  M Pezzlo
Journal:  Clin Microbiol Rev       Date:  1988-07       Impact factor: 26.132

5.  A capacitive touch screen sensor for detection of urinary tract infections in portable biomedical devices.

Authors:  Carlos Honrado; Tao Dong
Journal:  Sensors (Basel)       Date:  2014-07-30       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.