Literature DB >> 3886689

Bioluminescence screening for bacteriuria.

J C Kolbeck, R A Padgett, E G Estevez, L J Harrell.   

Abstract

A rapid screening test (45 min) for bacteriuria was evaluated in 1,000 clinical urine specimens. The test procedure is based upon firefly luciferase analysis of bacterial ATP and uses the Lumac kit and Lumac M2010 Biocounter (3M Co., St. Paul, Minn.). The procedure allows for removal and destruction of nonbacterial ATP and subsequent analysis of bacterial ATP by firefly luciferase with a single photon counter. Results, expressed in relative light units, were compared with actual CFU by the calibrated loop technique. Sensitivities and specificities were calculated separately for clean-catch midstream specimens and for urines obtained by catheterization. The sensitivity for 719 clean-catch specimens with a Lumac cutoff of greater than or equal to 500 relative light units, representing greater than or equal to 10(5) CFU/ml, was 93%. The sensitivity for 281 catheterized specimens with a Lumac cutoff of greater than or equal to 200 relative light units, representing greater than or equal to 10(4) CFU/ml, was 95%. There were 19 false-negative results in the 1,000 specimens tested; more than 50% of these were contaminated cultures and were not considered significant in determining bacteriuria. In conclusion, the Lumac bioluminescence assay is a reliable, rapid bacteriuria screening technique with the potential of reducing the laboratory cost and for reducing the turnaround time in processing negative urine cultures.

Entities:  

Mesh:

Year:  1985        PMID: 3886689      PMCID: PMC271712          DOI: 10.1128/jcm.21.4.527-530.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Pyelonephritis and bacteriuria. A major problem in preventive medicine.

Authors:  E H KASS
Journal:  Ann Intern Med       Date:  1962-01       Impact factor: 25.391

2.  Bacteriuria and the diagnosis of infections of the urinary tract; with observations on the use of methionine as a urinary antiseptic.

Authors:  E H KASS
Journal:  AMA Arch Intern Med       Date:  1957-11

3.  Limits of applicability of the firefly luminescence ATP assay for the detection of bacteria in clinical specimens.

Authors:  R B Conn; P Charache; E W Chappelle
Journal:  Am J Clin Pathol       Date:  1975-04       Impact factor: 2.493

Review 4.  Applications of bio- and chemiluminescence in the clinical laboratory.

Authors:  F Gorus; E Schram
Journal:  Clin Chem       Date:  1979-04       Impact factor: 8.327

5.  Evaluation of the MS-2 and Lumac systems for the rapid screening of urine specimens.

Authors:  W D Welch; M A Layman; P M Southern
Journal:  Am J Clin Pathol       Date:  1984-05       Impact factor: 2.493

6.  Comparison of the Lumac and Monolight systems for detection of bacteriuria by bioluminescence.

Authors:  D L Drow; C H Baum; G Hirschfield
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

7.  Evaluation of the Lumac kit for the detection of bacteriuria by bioluminescence.

Authors:  D Mackett; S Kessock-Philip; S Bascomb; C S Easmon
Journal:  J Clin Pathol       Date:  1982-01       Impact factor: 3.411

8.  Evaluation of two bioluminescence-measuring instruments, the Turner Design and Lumac systems, for the rapid screening of urine specimens.

Authors:  W D Welch; L Thompson; M Layman; P M Southern
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

9.  Causes of the acute urethral syndrome in women.

Authors:  W E Stamm; K F Wagner; R Amsel; E R Alexander; M Turck; G W Counts; K K Holmes
Journal:  N Engl J Med       Date:  1980-08-21       Impact factor: 91.245

  9 in total
  8 in total

Review 1.  Treatment of urinary tract infection. Clinical and economic considerations.

Authors:  R J Plumridge; C L Golledge
Journal:  Pharmacoeconomics       Date:  1996-04       Impact factor: 4.981

2.  Rapid screening for bacteriuria in pregnancy.

Authors:  W Graninger; D Fleischmann; B Schneeweiss; L Aram; F Stockenhuber
Journal:  Infection       Date:  1992 Jan-Feb       Impact factor: 3.553

3.  Reliability of a bioluminescence ATP assay for detection of bacteria.

Authors:  L Selan; F Berlutti; C Passariello; M C Thaller; G Renzini
Journal:  J Clin Microbiol       Date:  1992-07       Impact factor: 5.948

4.  Rapid antimicrobial susceptibility determination of uropathogens in clinical urine specimens by use of ATP bioluminescence.

Authors:  Vesna Ivancic; Mitra Mastali; Neil Percy; Jeffrey Gornbein; Jane T Babbitt; Yang Li; Elliot M Landaw; David A Bruckner; Bernard M Churchill; David A Haake
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

5.  Simplified technique for detection of significant bacteriuria by microscopic examination of urine.

Authors:  C L Cardoso; C B Muraro; V L Siqueira; M Guilhermetti
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

6.  Automated bacteriuria screening using the Berthold LB 950 luminescence analyser.

Authors:  G D Curtis; H H Johnston; A R Hack
Journal:  Eur J Clin Microbiol       Date:  1987-06       Impact factor: 3.267

7.  FiltraCheck-UTI, a rapid, disposable system for detection of bacteriuria.

Authors:  C C Longoria; G A Gonzalez
Journal:  J Clin Microbiol       Date:  1987-05       Impact factor: 5.948

8.  An Intact Cell Bioluminescence-Based Assay for the Simple and Rapid Diagnosis of Urinary Tract Infection.

Authors:  Sherwin Reyes; Nga Le; Mary Denneth Fuentes; Jonathan Upegui; Emre Dikici; David Broyles; Edward Quinto; Sylvia Daunert; Sapna K Deo
Journal:  Int J Mol Sci       Date:  2020-07-16       Impact factor: 5.923

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.