Evaluation of the MS-2 and Lumac systems for the rapid screening of urine specimens.

W D Welch, M A Layman, P M Southern.   

Abstract

The authors have evaluated the MS-2 (Abbott) and Lumac (3M) systems for the rapid screening of urine specimens for bacteriuria. These systems, which can detect significant levels of microorganisms in urine in five hours (MS-2) or 30 minutes (Lumac), were compared with a standard overnight plate culture method. Three hundred fifty-eight voided urine specimens were examined. The two systems compared equally at greater than 10(5) colony-forming units (CFU)/mL in terms of false-positive results (11%), false-negative results (2%), sensitivity (98%), specificity (approximately equal to 86%), and positive predictive value (98%), although the Lumac was found to have a lower negative predictive value (by 10%) than the MS-2. The only organism not recognized by the MS-2 at greater than 10(5) CFU/mL was a Lactobacillus; whereas the only specimens missed by the Lumac at greater than 10(5) CFU/mL were two pure cultures of Escherichia coli. At counts of greater than 10(4) to 10(5) CFU/mL, both systems missed numerous (15 of 21 isolates for the MS-2; 12 of 9 isolates for the Lumac) gram-positive cocci. The Lumac system was the most costly, being 3.6 times as expensive as the standard plate method. Although both systems greatly reduce the time required to process urine specimens, the large number of false-positive results, false-negative results at greater than 10(4) to 10(5) CFU/mL, as well as cost suggest that a careful evaluation of a laboratory's specific needs for urine cultures be made to determine whether or not such rapid urine screening systems are appropriate.

Entities:  

Mesh:

Year:  1984        PMID: 6372433     DOI: 10.1093/ajcp/81.5.629

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  5 in total

1.  Reliability of a bioluminescence ATP assay for detection of bacteria.

Authors:  L Selan; F Berlutti; C Passariello; M C Thaller; G Renzini
Journal:  J Clin Microbiol       Date:  1992-07       Impact factor: 5.948

2.  Rapid antimicrobial susceptibility determination of uropathogens in clinical urine specimens by use of ATP bioluminescence.

Authors:  Vesna Ivancic; Mitra Mastali; Neil Percy; Jeffrey Gornbein; Jane T Babbitt; Yang Li; Elliot M Landaw; David A Bruckner; Bernard M Churchill; David A Haake
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

3.  Automated bacteriuria screening using the Berthold LB 950 luminescence analyser.

Authors:  G D Curtis; H H Johnston; A R Hack
Journal:  Eur J Clin Microbiol       Date:  1987-06       Impact factor: 3.267

4.  Bioluminescence screening for bacteriuria.

Authors:  J C Kolbeck; R A Padgett; E G Estevez; L J Harrell
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

Review 5.  Detection of urinary tract infections by rapid methods.

Authors:  M Pezzlo
Journal:  Clin Microbiol Rev       Date:  1988-07       Impact factor: 26.132