Literature DB >> 7061712

Evaluation of the Lumac kit for the detection of bacteriuria by bioluminescence.

D Mackett, S Kessock-Philip, S Bascomb, C S Easmon.   

Abstract

Four hundred and twenty-two urine samples were screened for significant bacteriuria using bioluminescence and microscopy of uncentrifuged urine. A smaller number of false-negatives were seen with bioluminescence (10%) than with microscopy (40%) while both techniques gave a similar number of false-positives (18%). The kit required a large amount of manual preparation, largely pipetting. With this and the short shelf-life of the reconstituted reagents, it is not suitable for small numbers of urines. At 45p per urine, the cost of bioluminescence is too high.

Mesh:

Substances:

Year:  1982        PMID: 7061712      PMCID: PMC497457          DOI: 10.1136/jcp.35.1.107

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  8 in total

1.  A DISPOSABLE COUNTING CHAMBER FOR URINARY CYTOLOGY.

Authors:  G R HILSON
Journal:  J Clin Pathol       Date:  1964-09       Impact factor: 3.411

2.  Limits of applicability of the firefly luminescence ATP assay for the detection of bacteria in clinical specimens.

Authors:  R B Conn; P Charache; E W Chappelle
Journal:  Am J Clin Pathol       Date:  1975-04       Impact factor: 2.493

3.  Significance of coagulase-negative Staphylococcus in urine.

Authors:  R R Bailey
Journal:  J Infect Dis       Date:  1973-02       Impact factor: 5.226

4.  Detection of bacteriuria by luciferase assay of adenosine triphosphate.

Authors:  A Thore; S Anséhn; A Lundin; S Bergman
Journal:  J Clin Microbiol       Date:  1975-01       Impact factor: 5.948

5.  Automated direct antimicrobial susceptibility testing of microscopically screened urine cultures.

Authors:  R E Tilton; R C Tilton
Journal:  J Clin Microbiol       Date:  1980-02       Impact factor: 5.948

6.  An automated test for the detection of significant bacteriuria.

Authors:  H H Johnston; C J Mitchell; G D Curtis
Journal:  Lancet       Date:  1976-08-21       Impact factor: 79.321

7.  Simplified microscopy for rapid detection of significant bacteriuria in random urine specimens.

Authors:  G K Barbin; J D Thorley; J A Reinarz
Journal:  J Clin Microbiol       Date:  1978-03       Impact factor: 5.948

8.  METHOD FOR THE DETECTION OF SIGNIFICANT BACTERIURIA IN LARGE GROUPS OF PATIENTS.

Authors:  D A LEIGH; J D WILLIAMS
Journal:  J Clin Pathol       Date:  1964-09       Impact factor: 3.411

  8 in total
  12 in total

1.  Reliability of a bioluminescence ATP assay for detection of bacteria.

Authors:  L Selan; F Berlutti; C Passariello; M C Thaller; G Renzini
Journal:  J Clin Microbiol       Date:  1992-07       Impact factor: 5.948

2.  Rapid antimicrobial susceptibility determination of uropathogens in clinical urine specimens by use of ATP bioluminescence.

Authors:  Vesna Ivancic; Mitra Mastali; Neil Percy; Jeffrey Gornbein; Jane T Babbitt; Yang Li; Elliot M Landaw; David A Bruckner; Bernard M Churchill; David A Haake
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

3.  Evaluation of six screening methods for detecting significant bacteriuria.

Authors:  T K Smith; A J Hudson; R C Spencer
Journal:  J Clin Pathol       Date:  1988-08       Impact factor: 3.411

4.  Automated bacteriuria screening using the Berthold LB 950 luminescence analyser.

Authors:  G D Curtis; H H Johnston; A R Hack
Journal:  Eur J Clin Microbiol       Date:  1987-06       Impact factor: 3.267

5.  Evaluation of Malthus 128H microbiological growth analyser for detecting significant bacteriuria.

Authors:  T K Smith; R Eggington; A A Pease; D M Harris; R C Spencer
Journal:  J Clin Pathol       Date:  1985-08       Impact factor: 3.411

6.  Bioluminescence for USP sterility testing of pharmaceutical suspension products.

Authors:  D M Bussey; K Tsuji
Journal:  Appl Environ Microbiol       Date:  1986-02       Impact factor: 4.792

7.  Bioluminescence screening for bacteriuria.

Authors:  J C Kolbeck; R A Padgett; E G Estevez; L J Harrell
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

8.  Comparison of the Lumac and Monolight systems for detection of bacteriuria by bioluminescence.

Authors:  D L Drow; C H Baum; G Hirschfield
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

9.  Evaluation of a commercially available semi-automated bioluminescence system for bacteriuria screening.

Authors:  P W McWalter; C A Sharp
Journal:  Eur J Clin Microbiol       Date:  1982-08       Impact factor: 3.267

10.  ATP measurements obtained by luminometry provide rapid estimation of Ureaplasma urealyticum growth.

Authors:  M E Stemler; G W Stemke; J A Robertson
Journal:  J Clin Microbiol       Date:  1987-02       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.