Literature DB >> 7595684

Noninvasive blood pressure monitoring from the supraorbital artery using an artificial neural network oscillometric algorithm.

S Narus1, T Egbert, T K Lee, J Lu, D Westenskow.   

Abstract

OBJECTIVE: Our objective was to overcome the limitations of linear models of oscillometric blood pressure determination by using a nonlinear technique to model the relationship between the oscillometric envelope and systolic and diastolic blood pressures, and then to use that technique for near-continuous arterial pressure monitoring at the supraorbital artery.
METHODS: An adhesive pressure pad and transducer were used to collect oscillometric data from the supraorbital artery of 85 subjects. These data were then used to train an artificial neural network (ANN) to report diastolic or systolic pressure. Arterial pressure measurements defined by brachial artery auscultation were used as a reference. ANN results were compared with those obtained using a standard oscillometric algorithm that determined pressures based on fixed percentages of the maximum oscillometric amplitude.
RESULTS: The ANN produced better estimates of reference blood pressures than the standard oscillometric algorithm. Mean difference between target and actual output for the ANN was 0.50 +/- 5.73 mm Hg for systolic pressures, compared to the mean difference of the standard algorithm of 2.78 +/- 19.38 mm Hg. For diastolic pressures, the ANN had a mean difference of 0.04 +/- 4.70 mm Hg, while the mean difference of the standard algorithm was -0.34 +/- 9.75 mm Hg.
CONCLUSIONS: The ANN produced a better model of the relationship between the oscillometric envelope and reference systolic and diastolic pressures than did the standard oscillometric algorithm. Noninvasive blood pressure measured from the supraorbital artery agreed with pressure measured by auscultation in the brachial artery, and may sometimes be more clinically useful than an arm cuff device.

Entities:  

Mesh:

Year:  1995        PMID: 7595684     DOI: 10.1007/BF01616986

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  6 in total

1.  Neural-network-based adaptive matched filtering for QRS detection.

Authors:  Q Xue; Y H Hu; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1992-04       Impact factor: 4.538

2.  Oscillometric determination of diastolic, mean and systolic blood pressure--a numerical model.

Authors:  F K Forster; D Turney
Journal:  J Biomech Eng       Date:  1986-11       Impact factor: 2.097

3.  Comparison of intra-arterial and automated oscillometric blood pressure measurement methods in postoperative hypertensive patients.

Authors:  P G Loubser
Journal:  Med Instrum       Date:  1986 Sep-Oct

4.  Indirect measurement of mean blood pressure in the anesthetized patient.

Authors:  M Yelderman; A K Ream
Journal:  Anesthesiology       Date:  1979-03       Impact factor: 7.892

5.  An assessment of the Dinamap 845.

Authors:  P Hutton; J Dye; C Prys-Roberts
Journal:  Anaesthesia       Date:  1984-03       Impact factor: 6.955

6.  Comparison of direct and indirect methods of measuring arterial blood pressure, part III.

Authors:  J M Bruner; L J Krenis; J M Kunsman; A P Sherman
Journal:  Med Instrum       Date:  1981 May-Jun
  6 in total
  3 in total

1.  Optimal sites for forehead oscillometric blood pressure monitoring.

Authors:  T K Lee; F H Silva; T P Egbert; D R Westenskow
Journal:  J Clin Monit       Date:  1995-09

2.  Comparison of blood pressure measured by oscillometry from the supraorbital artery and invasively from the radial artery.

Authors:  T K Lee; D R Westenkow
Journal:  J Clin Monit Comput       Date:  1998-02       Impact factor: 2.502

3.  Frequency-domain analysis of fNIRS fluctuations induced by rhythmic mental arithmetic.

Authors:  Sergio Molina-Rodríguez; Marcos Mirete-Fructuoso; Luis M Martínez; Joaquín Ibañez-Ballesteros
Journal:  Psychophysiology       Date:  2022-04-08       Impact factor: 4.348

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.