Abstract

The pattern electroretinogram has assumed greater clinical and experimental significance because of its inner retinal origins. However, clinical tests may be confounded by an artifact. We tested subjects varying reference electrode position and eye stimulated while employing the Dawson-Trick-Litzkow (DTL) fiber electrode as the active electrode. The presence of a statistically significant artifactual response could not be confirmed. However, the variability of responses elicited with the outer canthus was less and the signal-to-noise ratio greater than with other reference positions.

Mesh:

Year:  1987        PMID: 3678002     DOI: 10.1007/bf00149936

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  9 in total

1.  A gold foil electrode: extending the horizons for clinical electroretinography.

Authors:  G B Arden; R M Carter; C Hogg; I M Siegel; S Margolis
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-04       Impact factor: 4.799

2.  Uniocular recording of pattern ERG.

Authors:  G B Arden; C R Hogg; R M Carter
Journal:  Vision Res       Date:  1986       Impact factor: 1.886

3.  Recording the contralateral PERG: effect of different electrodes.

Authors:  N S Peachey; S Sokol; A Moskowitz
Journal:  Invest Ophthalmol Vis Sci       Date:  1983-11       Impact factor: 4.799

4.  Pattern electroretinogram: use of noncorneal skin electrodes.

Authors:  L E Leguire; G L Rogers
Journal:  Vision Res       Date:  1985       Impact factor: 1.886

5.  Recording the pattern electroretinogram: a cautionary note.

Authors:  W H Seiple; I M Siegel
Journal:  Invest Ophthalmol Vis Sci       Date:  1983-06       Impact factor: 4.799

6.  Spatial tuning of the pattern ERG across temporal frequency.

Authors:  T Berninger; R P Schuurmans
Journal:  Doc Ophthalmol       Date:  1985-10-30       Impact factor: 2.379

7.  The ERG in response to alternating gratings in patients with diseases of the peripheral visual pathway.

Authors:  A Fiorentini; L Maffei; M Pirchio; D Spinelli; V Porciatti
Journal:  Invest Ophthalmol Vis Sci       Date:  1981-09       Impact factor: 4.799

8.  Improved electrode for electroretinography.

Authors:  W W Dawson; G L Trick; C A Litzkow
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-09       Impact factor: 4.799

  9 in total
  6 in total

1.  Scotopic versus photopic pattern onset-offset electroretinograms.

Authors:  S Pallas; W Schmidt; E Dodt
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

2.  Prognostic value of pattern reversal visual-evoked potentials in idiopathic epiretinal membrane.

Authors:  M A Tilanus; M H Cuypers; N A Bemelmans; A J Pinckers
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-08       Impact factor: 3.117

3.  Relationship between transient and steady-state pattern electroretinograms: theoretical and experimental assessment.

Authors:  Özcan Özdamar; Jonathon Toft-Nielsen; Jorge Bohórquez; Vittorio Porciatti
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-12-04       Impact factor: 4.799

4.  Recording the oscillatory potentials of the electroretinogram with the DTL electrode.

Authors:  P Lachapelle; J Benoit; J M Little; B Lachapelle
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

5.  Reproducibility of pattern electroretinogram in glaucoma patients with a range of severity of disease with the new glaucoma paradigm.

Authors:  Marie-Josée Fredette; Douglas R Anderson; Vittorio Porciatti; William Feuer
Journal:  Ophthalmology       Date:  2007-11-05       Impact factor: 12.079

6.  Effects of reference electrode location on monopolar-derived multifocal electroretinograms in cynomolgus monkeys.

Authors:  Charlene B Y Kim; James N VerHoeve; Paul L Kaufman; T Michael Nork
Journal:  Doc Ophthalmol       Date:  2006-03-02       Impact factor: 1.854

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.