Literature DB >> 3676019

Blood flow patterns in the human aorta studied by magnetic resonance.

R H Klipstein1, D N Firmin, S R Underwood, R S Rees, D B Longmore.   

Abstract

Magnetic resonance velocity mapping by the field even echo rephasing sequence was used to provide two dimensional velocity profiles in the ascending and the descending aorta. Flow patterns were studied in ten healthy volunteers by a display method that gave clear details of the profiles. Velocity profiles in the ascending aorta were skewed in systole with an axis of skew roughly symmetrical about the plane of the aortic arch. During diastole flow was reversed along the posterior left wall of the ascending aorta while it continued forwards at the anterior right wall. In the descending aorta plug flow occurred but with minimal skew. Flow along the right wall was reversed during diastole. Turbulent flow did not occur in the ascending or descending aorta of any healthy subject. Magnetic resonance velocity mapping is a very powerful tool for the study of cardiovascular physiology. Its non-invasiveness, its quantitative two-dimensional data, its accuracy, and its high spatial resolution make it suitable for clinical use.

Entities:  

Mesh:

Year:  1987        PMID: 3676019      PMCID: PMC1277261          DOI: 10.1136/hrt.58.4.316

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  15 in total

1.  HYDRODYNAMICS OF AORTIC BLOOD FLOW.

Authors:  E D FREIS; W C HEATH
Journal:  Circ Res       Date:  1964-02       Impact factor: 17.367

2.  Right atrial flow topography in healthy subjects studied with real-time two-dimensional Doppler flow imaging technique.

Authors:  K Miyatake; S Izumi; A Shimizu; N Kinoshita; M Okamoto; H Sakakibara; Y Nimura
Journal:  J Am Coll Cardiol       Date:  1986-02       Impact factor: 24.094

3.  Dynamics of aortic flow in hypertrophic cardiomyopathy.

Authors:  R Jenni; K Ruffmann; A Vieli; M Anliker; H P Krayenbuehl
Journal:  Eur Heart J       Date:  1985-05       Impact factor: 29.983

4.  Velocity patterns in the aorta.

Authors:  W A Seed; N B Wood
Journal:  Cardiovasc Res       Date:  1971-07       Impact factor: 10.787

5.  A comparison between single gate and multigate ultrasonic Doppler measurements for the assessment of the velocity pattern in the human ascending aorta.

Authors:  R Jenni; A Vieli; K Ruffmann; H P Krayenbuehl; M Anliker
Journal:  Eur Heart J       Date:  1984-11       Impact factor: 29.983

6.  Measurement of flow with NMR imaging using a gradient pulse and phase difference technique.

Authors:  D J Bryant; J A Payne; D N Firmin; D B Longmore
Journal:  J Comput Assist Tomogr       Date:  1984-08       Impact factor: 1.826

7.  Three-dimensional visualization of velocity profiles in the ascending aorta in dogs, measured with a hot-film anemometer.

Authors:  P K Paulsen; J M Hasenkam
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

8.  Clinical applications of a new type of real-time two-dimensional Doppler flow imaging system.

Authors:  K Miyatake; M Okamoto; N Kinoshita; S Izumi; M Owa; S Takao; H Sakakibara; Y Nimura
Journal:  Am J Cardiol       Date:  1984-10-01       Impact factor: 2.778

Review 9.  Principles of nuclear magnetic resonance imaging.

Authors:  I L Pykett; J H Newhouse; F S Buonanno; T J Brady; M R Goldman; J P Kistler; G M Pohost
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

10.  Dimensional accuracy of magnetic resonance in studies of the heart.

Authors:  D B Longmore; R H Klipstein; S R Underwood; D N Firmin; G N Hounsfield; M Watanabe; C Bland; K Fox; P A Poole-Wilson; R S Rees
Journal:  Lancet       Date:  1985-06-15       Impact factor: 79.321

View more
  18 in total

1.  Analysis of flow patterns using MRI.

Authors:  M H Buonocore; H G Bogren
Journal:  Int J Card Imaging       Date:  1999-04

Review 2.  Complex flow patterns in the great vessels: a review.

Authors:  H G Bogren; M H Buonocore
Journal:  Int J Card Imaging       Date:  1999-04

3.  Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla.

Authors:  Alex Frydrychowicz; Alexander Berger; Alejandro Munoz Del Rio; Maximilian F Russe; Jelena Bock; Andreas Harloff; Michael Markl
Journal:  Eur Radiol       Date:  2011-12-30       Impact factor: 5.315

4.  Visualization of through-plane blood flow measurements obtained from phase-contrast MRI.

Authors:  Per Thunberg; Anders Kähäri
Journal:  J Digit Imaging       Date:  2011-06       Impact factor: 4.056

5.  Velocity distribution model for normal blood flow in the human ascending aorta.

Authors:  L Segadal
Journal:  Med Biol Eng Comput       Date:  1991-09       Impact factor: 2.602

Review 6.  Nuclear magnetic resonance in clinical pharmacology and measurement of therapeutic response.

Authors:  W H Aellig
Journal:  Br J Clin Pharmacol       Date:  1990-02       Impact factor: 4.335

Review 7.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

8.  Magnetic resonance velocity mapping of normal human transmitral velocity profiles.

Authors:  S Fujimoto; R H Mohiaddin; K H Parker; D G Gibson
Journal:  Heart Vessels       Date:  1995       Impact factor: 2.037

9.  Cross sectional early mitral flow velocity profiles from colour Doppler.

Authors:  S O Samstad; H G Torp; D T Linker; O Rossvoll; T Skjaerpe; E Johansen; K Kristoffersen; B A Angelsen; L Hatle
Journal:  Br Heart J       Date:  1989-09

10.  Geometric risk factors for atherosclerosis in the aortic bifurcation: a digitized angiography study.

Authors:  O Smedby
Journal:  Ann Biomed Eng       Date:  1996 Jul-Aug       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.