Literature DB >> 20358243

Visualization of through-plane blood flow measurements obtained from phase-contrast MRI.

Per Thunberg1, Anders Kähäri.   

Abstract

The purpose of this work was to develop a visualization method for concurrent observation of both velocity and magnitude data obtained from through-plane velocity measurements using phase-contrast magnetic resonance imaging. Magnitude and velocity images were combined using an opacity transfer function (OTF) where the opacity was a function of a velocity range defined by the velocity encoding (v (enc)) parameter. Measured velocities were color-coded according to a predefined color scale and then combined into one image with the gray-scale magnitude image according to the OTF. In the combined images, simultaneous information of velocity and anatomy was presented. The proposed visualization method facilitated the understanding of how the measured blood flow was related to the underlying anatomy. Results are shown where the method is used to visualize blood flow measurements in the ascending aorta and the aortic valve. Adjustments of the OTF render possible identification of the peak velocities and their localization. Forward and backward blood flow is easily shown when applying appropriate OTF and color-coding. An advantage when using the proposed method is the ability of developing standardized protocol settings since the velocity information is quantitative and not relative as is the case for data obtained from the magnitude images. The intended application of the visualization method is the analysis of common flow studies used in the diagnosis of different cardiovascular diseases.

Entities:  

Mesh:

Year:  2011        PMID: 20358243      PMCID: PMC3092048          DOI: 10.1007/s10278-010-9286-5

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  18 in total

1.  Real-time color flow MRI.

Authors:  K S Nayak; J M Pauly; A B Kerr; B S Hu; D G Nishimura
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

2.  Three-dimensional volume rendering of spiral CT data: theory and method.

Authors:  P S Calhoun; B S Kuszyk; D G Heath; J C Carley; E K Fishman
Journal:  Radiographics       Date:  1999 May-Jun       Impact factor: 5.333

3.  Left-to-right cardiac shunts: comparison of measurements obtained with MR velocity mapping and with radionuclide angiography.

Authors:  H Arheden; C Holmqvist; U Thilen; K Hanséus; G Björkhem; O Pahlm; S Laurin; F Ståhlberg
Journal:  Radiology       Date:  1999-05       Impact factor: 11.105

4.  Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: implications for aortic valve-sparing surgery.

Authors:  John-Peder Escobar Kvitting; Tino Ebbers; Lars Wigström; Jan Engvall; Christian L Olin; Ann F Bolger
Journal:  J Thorac Cardiovasc Surg       Date:  2004-06       Impact factor: 5.209

Review 5.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

Review 6.  Magnetic resonance imaging of valvular heart disease.

Authors:  L Søndergaard; F Ståhlberg; C Thomsen
Journal:  J Magn Reson Imaging       Date:  1999-11       Impact factor: 4.813

7.  Improved measurement of pressure gradients in aortic coarctation by magnetic resonance imaging.

Authors:  J N Oshinski; W J Parks; C P Markou; H L Bergman; B E Larson; D N Ku; S Mukundan; R I Pettigrew
Journal:  J Am Coll Cardiol       Date:  1996-12       Impact factor: 24.094

8.  Assessment of chronic aortic dissection: contribution of different ECG-gated breath-hold MRI techniques.

Authors:  R Peter Kunz; Katja Oberholzer; Wlodzimierz Kuroczynski; Georg Horstick; Frank Krummenauer; Manfred Thelen; Karl-Friedrich Kreitner
Journal:  AJR Am J Roentgenol       Date:  2004-05       Impact factor: 3.959

9.  Blood velocity distribution in the human ascending aorta.

Authors:  L Segadal; K Matre
Journal:  Circulation       Date:  1987-07       Impact factor: 29.690

10.  Time-resolved three-dimensional phase-contrast MRI.

Authors:  Michael Markl; Frandics P Chan; Marcus T Alley; Kris L Wedding; Mary T Draney; Chris J Elkins; David W Parker; Ryan Wicker; Charles A Taylor; Robert J Herfkens; Norbert J Pelc
Journal:  J Magn Reson Imaging       Date:  2003-04       Impact factor: 4.813

View more
  2 in total

1.  Intra- and inter-reader reproducibility of blood flow measurements on the ascending aorta and pulmonary artery using cardiac magnetic resonance.

Authors:  Giovanni Di Leo; Ida Daniela D'Angelo; Marco Alì; Paola Maria Cannaò; Giovanni Mauri; Francesco Secchi; Francesco Sardanelli
Journal:  Radiol Med       Date:  2016-11-22       Impact factor: 3.469

Review 2.  Recommendation for Cardiac Magnetic Resonance Imaging-Based Phenotypic Study: Imaging Part.

Authors:  Chengyan Wang; Yan Li; Jun Lv; Jianhua Jin; Xumei Hu; Xutong Kuang; Weibo Chen; He Wang
Journal:  Phenomics       Date:  2021-07-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.