Literature DB >> 1817210

Velocity distribution model for normal blood flow in the human ascending aorta.

L Segadal1.   

Abstract

During the study of velocities in the human ascending aorta it became necessary to establish a method for two-dimensional velocity profiles from discrete velocity data obtained from different heartbeats and with different techniques. A descriptive geometrical model was therefore developed and expanded to 16 elements each containing 16 constants by a serial optimising technique using a least-squares method. Published data from two different studies on velocity distribution in the ascending aorta comprising six subjects with normal aortic valves were used. Three-dimensional graphic displays of velocity profile at different time intervals of the heart cycle clearly show common features of distribution of velocity at a point 6 cm above the aortic valve. There was a pronounced skewness with clockwise rotation of the skewness direction during systole, reversed flow directed towards the left coronary sinus of Valsalva in late systole and early diastole concomitant with secondary flow augmentation along the opposite wall of the aorta. Consistent plane-symmetric features during the heart cycle could not be demonstrated.

Entities:  

Mesh:

Year:  1991        PMID: 1817210     DOI: 10.1007/BF02442319

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Blood flow patterns in the human aorta studied by magnetic resonance.

Authors:  R H Klipstein; D N Firmin; S R Underwood; R S Rees; D B Longmore
Journal:  Br Heart J       Date:  1987-10

2.  Velocity patterns in the aorta.

Authors:  W A Seed; N B Wood
Journal:  Cardiovasc Res       Date:  1971-07       Impact factor: 10.787

3.  Continuous measurement of aortic blood velocity, after cardiac surgery, by means of an extractable Doppler ultrasound probe.

Authors:  K Matre; L Segadal; H Engedal
Journal:  J Biomed Eng       Date:  1985-04

4.  A comparison between single gate and multigate ultrasonic Doppler measurements for the assessment of the velocity pattern in the human ascending aorta.

Authors:  R Jenni; A Vieli; K Ruffmann; H P Krayenbuehl; M Anliker
Journal:  Eur Heart J       Date:  1984-11       Impact factor: 29.983

5.  A removable extraluminal Doppler probe for continuous monitoring of changes in cardiac output.

Authors:  B A Keagy; C L Lucas; H S Hsiao; B R Wilcox
Journal:  J Ultrasound Med       Date:  1983-08       Impact factor: 2.153

6.  Three-dimensional visualization of velocity profiles in the ascending aorta in dogs, measured with a hot-film anemometer.

Authors:  P K Paulsen; J M Hasenkam
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

7.  The velocity profile in the canine ascending aorta and its effects on the accuracy of pulsed Doppler determinations of mean blood velocity.

Authors:  C L Lucas; B A Keagy; H S Hsiao; T A Johnson; G W Henry; B R Wilcox
Journal:  Cardiovasc Res       Date:  1984-05       Impact factor: 10.787

8.  Spatial velocity distributions in the ascending aorta of healthy humans and cardiac patients.

Authors:  A Vieli; R Jenni; M Anliker
Journal:  IEEE Trans Biomed Eng       Date:  1986-01       Impact factor: 4.538

9.  Blood velocity distribution in the human ascending aorta.

Authors:  L Segadal; K Matre
Journal:  Circulation       Date:  1987-07       Impact factor: 29.690

  9 in total
  2 in total

1.  Intraluminal recording of cross-sectional blood velocity distribution of human ascending aorta by ultrasound Doppler technique.

Authors:  I Hessevik; K Matre; P Kvitting; L Segadal
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

2.  Evaluation of aortic regurgitation in congenital heart disease: value of MR imaging in comparison to echocardiography.

Authors:  Sebastian Ley; Joachim Eichhorn; Julia Ley-Zaporozhan; Herbert Ulmer; Jens-Peter Schenk; Hans-Ulrich Kauczor; Raoul Arnold
Journal:  Pediatr Radiol       Date:  2007-03-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.