Literature DB >> 19842049

Transesophageal Doppler devices: A technical review.

Patrick Schober1, Stephan A Loer, Lothar A Schwarte.   

Abstract

Monitoring of aortic blood flow, conducting large portions of the cardiac output (CO), allows conclusions on the global hemodynamic status of patients. For this purpose, transesophageal Doppler (TED) devices have been developed, which interrogate the descending aorta and calculate aortic blood flow velocity using the Doppler principle. The recorded velocity-time curve can be used to estimate CO as well other advanced hemodynamic parameters such as preload, afterload and myocardial contractility. Clinical studies in perioperative patients have demonstrated a reduced postoperative morbidity and shorter length of hospital stay when TED is used to guide fluid management. However, several assumptions are needed to translate the measured Doppler frequency shift to hemo- dynamic variables and discrepancies between the assumed and the actual condition may introduce a considerable risk for erroneous calculations. A correct interpretation of the displayed parameters requires profound knowledge on the technical basis of this method as well as its technical limitations. Our review focuses on these technical aspects which the clinician should be familiar with to allow proper use of TED monitoring devices.

Entities:  

Mesh:

Year:  2009        PMID: 19842049     DOI: 10.1007/s10877-009-9204-x

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  101 in total

1.  A comparison of hemodynamic data derived by pulmonary artery flotation catheter and the esophageal Doppler monitor in preeclampsia.

Authors:  J A Penny; J Anthony; A H Shennan; M De Swiet; M Singer
Journal:  Am J Obstet Gynecol       Date:  2000-09       Impact factor: 8.661

2.  The use of oesophageal Doppler cardiac output measurement to optimize fluid management during colorectal surgery.

Authors:  M R McFall; W G A Woods; H G Wakeling
Journal:  Eur J Anaesthesiol       Date:  2004-07       Impact factor: 4.330

3.  Intraoperative assessment of the Lawrence 3000 Doppler Cardiac Output Monitor.

Authors:  M S Stein; S M Barratt; G J Purcell
Journal:  Anaesth Intensive Care       Date:  1991-05       Impact factor: 1.669

4.  Continuous measurement of cardiac output during aortic cross-clamping by the oesophageal Doppler monitor ODM 1.

Authors:  K F Klotz; S Klingsiek; M Singer; H Wenk; S Eleftheriadis; H Kuppe; P Schmucker
Journal:  Br J Anaesth       Date:  1995-06       Impact factor: 9.166

5.  Noninvasive versus invasive assessment of cardiac output after cardiac surgery: clinical validation.

Authors:  D R Spahn; E R Schmid; M Tornic; R Jenni; L von Segesser; M Turina; A Baetscher
Journal:  J Cardiothorac Anesth       Date:  1990-02

6.  Relationship between age, body size, gender, and blood pressure and Doppler flow measurements in the aorta and pulmonary artery.

Authors:  J M Gardin; D M Davidson; M K Rohan; S Butman; M Knoll; R Garcia; S Dubria; S K Gardin; W L Henry
Journal:  Am Heart J       Date:  1987-01       Impact factor: 4.749

7.  Blood flow patterns in the human aorta studied by magnetic resonance.

Authors:  R H Klipstein; D N Firmin; S R Underwood; R S Rees; D B Longmore
Journal:  Br Heart J       Date:  1987-10

8.  Transoesophageal aortic velography in man.

Authors:  P J Tomlin; F A Duck
Journal:  Can Anaesth Soc J       Date:  1975-09

9.  Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery.

Authors:  Tong J Gan; Andrew Soppitt; Mohamed Maroof; Habib el-Moalem; Kerri M Robertson; Eugene Moretti; Peter Dwane; Peter S A Glass
Journal:  Anesthesiology       Date:  2002-10       Impact factor: 7.892

10.  Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery.

Authors:  M G Mythen; A R Webb
Journal:  Arch Surg       Date:  1995-04
View more
  1 in total

Review 1.  From system to organ to cell: oxygenation and perfusion measurement in anesthesia and critical care.

Authors:  Patrick Schober; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2012-03-22       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.