Literature DB >> 2861314

Dimensional accuracy of magnetic resonance in studies of the heart.

D B Longmore, R H Klipstein, S R Underwood, D N Firmin, G N Hounsfield, M Watanabe, C Bland, K Fox, P A Poole-Wilson, R S Rees.   

Abstract

Magnetic resonance (MR) can provide high-resolution tomographic images of the heart at any part of the cardiac cycle. Tests on static and dynamic phantoms showed that the technique can give accurate measurements of ventricular wall thickness, cavity volume, and stroke volume. In 20 patients with angina pectoris, electrocardiographically gated MR images of the left ventricle were compared with X-ray contrast ventriculograms. There was good correlation with the anteroposterior ventriculogram, but poorer correlation in the lateral projection because of difficulty in locating the aortic valve precisely on the ventriculogram. In 20 normal subjects, left and right ventricular volumes at end-diastole and end-systole were measured by summing the areas of the cavities in multiple contiguous sections. Stroke volumes and ejection fractions were thus calculated, and the ratio of left to right ventricular stroke volume was very close to the theoretical value of 1, in all cases. In any individual volume measurement, the error was approximately 2%. MR therefore provides an accurate non-invasive method of studying cardiac dimensions and function.

Entities:  

Mesh:

Year:  1985        PMID: 2861314     DOI: 10.1016/s0140-6736(85)91786-6

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  42 in total

Review 1.  Magnetic resonance imaging in valvular heart disease.

Authors:  M Schmidt; J Crnac; B Dederichs; P Theissen; H Schicha; U Sechtem
Journal:  Int J Card Imaging       Date:  1997-06

2.  Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN.

Authors:  I Paetsch; H Thiele; B Schnackenburg; A Bornstedt; A Müller-York; J Schwab; E Fleck; E Nagel
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

Review 3.  Magnetic resonance imaging assessment of cardiac function.

Authors:  W Gregory Hundley; Craig A Hamilton; Pairoj Rerkpattanapipat
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

4.  Maximal oxygen consumption is best predicted by measures of cardiac size rather than function in healthy adults.

Authors:  André La Gerche; Andrew T Burns; Andrew J Taylor; Andrew I Macisaac; Hein Heidbüchel; David L Prior
Journal:  Eur J Appl Physiol       Date:  2011-10-01       Impact factor: 3.078

5.  The reproducibility of left ventricular volume and mass measurements: a comparison between dual-inversion-recovery black-blood sequence and SSFP.

Authors:  Sarah Clay; Khaled Alfakih; Daniel R Messroghli; Timothy Jones; John P Ridgway; Mohan U Sivananthan
Journal:  Eur Radiol       Date:  2005-08-20       Impact factor: 5.315

6.  Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

Authors:  Marcus Katoh; Harald P Kühl; Elmar Spuentrup; Claudia S A Lipke; Rolf W Günther; Arno Buecker
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

7.  Is magnetic resonance imaging the 'reference standard' for cardiac functional assessment? Factors influencing measurement of left ventricular mass and volumes.

Authors:  H Steen; K Nasir; E Flynn; I El-Shehaby; S Lai; H A Katus; D Bluemcke; J A C Lima
Journal:  Clin Res Cardiol       Date:  2007-09-07       Impact factor: 5.460

8.  A simple method to estimate cardiac function during routine multi-row detector CT exams.

Authors:  Piet K Vanhoenacker; Lieven R Van Hoe
Journal:  Eur Radiol       Date:  2007-02-03       Impact factor: 5.315

9.  Assessment of regional left ventricular function by magnetic resonance.

Authors:  S R Underwood; R S Rees; P E Savage; R H Klipstein; D N Firmin; K M Fox; P A Poole-Wilson; D B Longmore
Journal:  Br Heart J       Date:  1986-10

10.  Magnetic resonance assessment of aortic and mitral regurgitation.

Authors:  S R Underwood; R H Klipstein; D N Firmin; K M Fox; P A Poole-Wilson; R S Rees; D B Longmore
Journal:  Br Heart J       Date:  1986-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.