Literature DB >> 3978918

A method of intraoperative limb length measurement in total hip arthroplasty.

S T Woolson, W H Harris.   

Abstract

Equalization of leg-length discrepancy during total hip arthroplasty is a major concern to both the patient and surgeon. A stable pelvic reference point must be established during surgery to determine leg-length changes. An accurate method of intraoperative leg-length measurement is presented to improve the surgeon's ability to determine the exact amount of limb lengthening or shortening occurring during total hip arthroplasty.

Entities:  

Mesh:

Year:  1985        PMID: 3978918

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  17 in total

1.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

2.  Improvement of activities of daily living after total hip arthroplasty using a computed tomography-based navigation system.

Authors:  Yuki Maeda; Nobuo Nakamura; Nobuhiko Sugano
Journal:  J Artif Organs       Date:  2017-02-27       Impact factor: 1.731

3.  Measurement and restoration of equality in length of the lower limbs in total hip replacement.

Authors:  V Hoikka; T Paavilainen; T S Lindholm; K B Turula; M Ylikoski
Journal:  Skeletal Radiol       Date:  1987       Impact factor: 2.199

4.  Optimizing leg length correction in total hip arthroplasty.

Authors:  Kenji Fujita; Tamon Kabata; Yoshitomo Kajino; Hiroyuki Tsuchiya
Journal:  Int Orthop       Date:  2019-10-09       Impact factor: 3.075

5.  Relationship between Perceived Leg Length Discrepancy at One Month and Preoperative Hip Abductor Muscle Elasticity in Patients after Total Hip Arthroplasty.

Authors:  Kodai Kinoshita; Kazushi Kimura; Shigenori Miyamoto; Yuichi Takata; Yuji Kodama; Akira Ieiri; Kazuhiro Ishida; Masahiro Inoue; Satomi Abe; Takashi Mikami; Taiki Kanno
Journal:  Phys Ther Res       Date:  2021-09-03

6.  Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Authors:  Xing Chen; Shuxing Xing; Zhiyong Zhu; Huisheng Wang; Zhongshen Yu; Xizhuang Bai; Xi Li
Journal:  Front Surg       Date:  2022-03-03

7.  Accuracy of the relationship between the centre of the femoral head and tip of greater trochanter.

Authors:  Baljinder S Dhinsa; Aaron Saini; Alastair G Dick; William J Nash; Obinna Nzeako; Zameer Shah
Journal:  J Clin Orthop Trauma       Date:  2018-08-24

8.  Reliability of relation between greater trochanter and center of rotation of femoral head in Indian population.

Authors:  Arvind Kumar; Jigyasa Passey; Mukesh Kumar; Dushyant Chouhan; Manish Saini; Saubhik Das
Journal:  J Clin Orthop Trauma       Date:  2020-04-21

9.  Accurate leg length measurement in total hip arthroplasty: a comparison of computer navigation and a simple manual measurement device.

Authors:  Kyoichi Ogawa; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Hiroyuki Tsuchiya
Journal:  Clin Orthop Surg       Date:  2014-05-16

10.  Three cases of type-1 complex regional pain syndrome after elective total hip replacement.

Authors:  Gerardo Zanotti; Pablo Ariel Slullitel; Fernando Martín Comba; Martín Alejandro Buttaro; Francisco Piccaluga
Journal:  SICOT J       Date:  2017-09-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.