| Literature DB >> 36123625 |
Jianjun Shen1, Shaobing Dai2, Xia Tao3, Xinzhong Chen2, Lili Xu4.
Abstract
BACKGROUND: Recent evidence suggests that ultrasound measurements of carotid and brachial artery corrected flow time (FTc) and respirophasic variation in blood flow peak velocity (ΔVpeak) are valuable for predicting fluid responsiveness in mechanical ventilated patients. We performed the study to reveal the performance of ultrasonic measurements of radial artery FTc and ΔVpeak for predicting fluid responsiveness in mechanical ventilated patients undergoing gynecological surgery.Entities:
Keywords: Corrected flow time; Fluid responsiveness; Gynecological; Radial artery; Respirophasic variation in blood flow peak velocity; Ultrasonography
Mesh:
Year: 2022 PMID: 36123625 PMCID: PMC9484168 DOI: 10.1186/s12871-022-01837-9
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.376
Fig. 1Example ultrasound images of radial artery FT and Vpeak. Radial artery FT and Vpeak were measured adjacent to the radial head. FTc was calculated by using a simplified formula FTc = FT+ [1.29 x (HR - 60)] [12]. ΔVpeak was calculated as follows: (maximum peak velocity-minimum peak velocity) / [(maximum peak velocity + minimum peak velocity)/2]× 100 [10]. FT: radial artery flow time; Vpeak: radial artery blood flow peak velocity
Patient characteristics
| Responders group ( | Non-responders group ( | ||
|---|---|---|---|
| Age (yr) | 33.3 ± 4.9 | 31.3 ± 5.6 | 0.090 |
| ASA (I/II) | 44/0 | 33/3 | 0.087 |
| Height (cm) | 160.0 ± 5.5 | 161.2 ± 5.6 | 0.321 |
| Weight (kg) | 55.4 ± 6.7 | 59.0 ± 8.9 | 0.054 |
| BMI | 21.7 ± 2.2 | 22.7 ± 3.1 | 0.096 |
| Duration of Surgery (min) | 108.4 ± 60.5 | 93.3 ± 31.1 | 0.154 |
BMI Body mass index (kg/m2), HR Heart rate, MAP Mean arterial pressure
Values are numbers or means±SD
*p < 0.05 compared with Responders group
Hemodynamic variables before and after fluid challenge
| Responders group | Non-responders group | |||||
|---|---|---|---|---|---|---|
| Before | After | Before | After | Before | After | |
FT radial artery corrected flow time, ΔVpeak respirophasic variation in radial artery blood flow peak velocity, PPV Pulse pressure variation, SVI Stroke volume index
Data are reported as mean ± SD
*p < 0.05 compared with before fluid challenge. #p < 0.05 compared with Responders group
Fig. 2Individual responses to fluid challenge and ROC curve for FTc, ΔVpeak and PPV. Upper row: individual responses to fluid challenge for FTc (A), ΔVpeak (B) and PPV (C). Responders are presented as blue full line and closed circles; Non-responders are presented as red dashed line and open circles. Lower row: receiver operating characteristic curves showing the ability of FTc (D), ΔVpeak (E) and PPV (F) before fluid challenge to discriminate responders and non-responders. The areas under the curves for FTc, ΔVpeak and PPV were 0.802 (95% confidence interval 0.706–0.898), 0.812 (95% confidence interval 0.714–0.909), and 0.846 (95% confidence interval 0.762–0.930), respectively. FTc: radial artery corrected flow time; ΔVpeak: respirophasic variation in radial artery blood flow peak velocity; PPV: pulse pressure variation
Multivariate logistic regression analyses identified the factors that were independently associated with fluid responsiveness
| Odds ratio (95% CI) | |||
|---|---|---|---|
| FTC (ms) | 0.142 | 0.004 | 1.152 (1.045–1.270) |
| ΔVpeak (%) | -0.543 | 0.004 | 0.581 (0.403–0.839) |
| PPV (%) | -1.018 | 0.001 | 0.361 (0.193–0.676) |
FT radial artery corrected flow time; ΔVpeak Respirophasic variation in radial artery blood flow peak velocity, PPV Pulse pressure variation
Prediction of fluid responsiveness by receiver operating characteristic curves of the baseline FTc, ΔVpeak and PPV
| AUROC curve | Optimal cut-off | Grey zone | Patients in grey zone (%) | Sensitivity | Specificity | Youden index (95% CI) | ||
|---|---|---|---|---|---|---|---|---|
| FTc | 0.802 (0.706–0.898) | 0.0004 | 336.6 msa | 313.5–336.6 ms | 40 (50%) | 0.75 (0.66–0.85) | 0.76 (0.71–1.00) | 0.477 |
| ΔVpeak | 0.812 (0.714–0.909) | 0.0002 | 14.2%a | 12.2–16.5% | 37 (46%) | 0.88 (0.79–0.97) | 0.68 (0.60–0.77) | 0.540 |
| PPV | 0.846 (0.762–0.930) | 0.0001 | 11.5%a | 7.5–11.5% | 48 (60%) | 0.74 (0.55–0.93) | 0.54 (0.46–0.63) | 0.614 |
AUROC Area under the receiver operating characteristic, CI Confidence interval, FTC Radial artery corrected flow time, ΔVpeak respirophasic variation in radial artery blood flow peak velocity, PPV Pulse pressure variation