Literature DB >> 1884612

Noninvasive optimization of left ventricular filling using esophageal Doppler.

M Singer1, E D Bennett.   

Abstract

OBJECTIVE: To confirm whether the descending aortic blood flow velocity waveform variable of flow time corrected for heart rate, measured using an esophageal Doppler transducer, can be used for noninvasive optimization of left ventricular (LV) filling.
SETTING: ICU and operating theater.
SUBJECTS: Forty-three mechanistically ventilated patients in the ICU or undergoing cardiothoracic surgery in whom a pulmonary arterial catheter was in situ.
INTERVENTIONS: LV preload was a) increased from hypovolemic states (pulmonary arterial occlusion pressure [PAOP] less than 8 mm Hg) by fluid challenge, b) decreased from normovolemic states (PAOP 10 to 15 mm Hg) by either iv nitrates or intravascular fluid loss, and c) decreased from heart failure or fluid overload states (PAOP greater than 20 mm Hg) by iv nitrates. No other maneuver was performed concurrently.
MEASUREMENTS AND MAIN RESULTS: Descending aortic blood flow was measured by an esophageal Doppler transducer. Corrected flow time was calculated by dividing systolic flow time by the square root of the cycle time. PAOP and corrected flow time increased after fluid challenges in hypovolemic states, and decreased when LV preload was decreased from normovolemic states. However, when preload was decreased from overload states, PAOP always decreased, but the corrected flow time usually increased before any subsequent decrease. The greatest value of corrected flow time corresponded with the maximal stroke volume seen.
CONCLUSIONS: Esophageal Doppler measurement of aortic blood flow can be used for rapid, noninvasive optimization of LV filling in mechanically ventilated patients.

Entities:  

Mesh:

Year:  1991        PMID: 1884612     DOI: 10.1097/00003246-199109000-00007

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  31 in total

1.  A validation study of electrical cardiometry in pregnant patients using transthoracic echocardiography as the reference standard.

Authors:  Erin Martin; Adanna Anyikam; Jerasimos Ballas; Kristen Buono; Kristin Mantell; Thao Huynh-Covey; Thomas Archer
Journal:  J Clin Monit Comput       Date:  2015-09-24       Impact factor: 2.502

2.  Methods of monitoring shock.

Authors:  Ednan K Bajwa; Atul Malhotra; B Taylor Thompson
Journal:  Semin Respir Crit Care Med       Date:  2004-12       Impact factor: 3.119

3.  Systolic duration, preload, and afterload: Is a new paradigm needed?

Authors:  Denis Chemla; Alain Nitenberg
Journal:  Intensive Care Med       Date:  2006-07-07       Impact factor: 17.440

4.  The FTc is not an accurate marker of left ventricular preload.

Authors:  Mervyn Singer
Journal:  Intensive Care Med       Date:  2006-04-28       Impact factor: 17.440

5.  Effects of isoflurane on Tei-index of myocardial performance in healthy dogs.

Authors:  Marlos Gonçalves Sousa; Roberta Carareto; Andrigo Barboza De-Nardi; Fábio L C Brito; Newton Nunes; Aparecido Antonio Camacho
Journal:  Can Vet J       Date:  2007-03       Impact factor: 1.008

6.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

Review 7.  [Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data].

Authors:  U Wittkowski; C Spies; M Sander; J Erb; A Feldheiser; C von Heymann
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

Review 8.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

9.  Limits of corrected flow time to monitor hemodynamic status in children.

Authors:  E Wodey; F Carre; X Beneux; A Schaffuser; C Ecoffey
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

10.  Randomised controlled trial assessing the impact of a nurse delivered, flow monitored protocol for optimisation of circulatory status after cardiac surgery.

Authors:  Moira McKendry; Helen McGloin; Debbie Saberi; Libby Caudwell; Anthony R Brady; Mervyn Singer
Journal:  BMJ       Date:  2004-07-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.