David Zweiker1,2,3, Basma El Sawaf1, Giuseppe D'Angelo1, Andrea Radinovic1, Alessandra Marzi1, Luca R Limite1, Antonio Frontera1,4, Gabriele Paglino1, Michael Spartalis1, Donah Zachariah1, Kenzaburo Nakajima1, Paolo Della Bella1, Patrizio Mazzone1.
Abstract
BACKGROUND: Limited data is available about the outcome of TLE in patients with vs. without high energy leads in the last decade.Entities:
Keywords: implantable cardiac defibrillator; retrospective analysis; risk score; transcatheter lead extraction
Year: 2022 PMID: 36013123 PMCID: PMC9410501 DOI: 10.3390/jcm11164884
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.964
Device details and indications for TLE, stratified by ICD and non-ICD groups.
| Parameter | Total | ICD | non-ICD | |
|---|---|---|---|---|
|
| ||||
| device type | <0.001 | |||
| - ICD | 34.8% ( | 52.6% ( | 7.3% ( | |
| - CRT-D | 33.7% ( | 47.4% ( | 12.6% ( | |
| - PM | 29.2% ( | 0% ( | 74.4% ( | |
| - CRT-P | 2.2% ( | 0% ( | 5.7% ( | |
| presence of a HIS lead | 0.3% ( | 0% ( | 0.8% ( | 0.154 |
| indication for implant | <0.001 | |||
| - DCM | 31.3% ( | 40.0% ( | 17.9% ( | |
| - ICM | 27.4% ( | 37% ( | 12.6% ( | |
| - AV block | 17.1% ( | 3.5% ( | 38.2% ( | |
| - SSS | 12% ( | 1.5% ( | 28.2% ( | |
| - inherited | 8.4% ( | 13.1% ( | 1.1% ( | |
| - VT/VF | 2.4% ( | 3.0% ( | 1.5% ( | |
| - not documented | 1.3% ( | 2.0% ( | 0.4% ( | |
| implanted leads | 2.4 ± 1.0 | 2.6 ± 0.9 | 2.1 ± 0.6 | <0.001 |
|
| ||||
| infection | 55.0% ( | 61.7% ( | 44.7% ( | <0.001 |
| - pocket infection | 35.1% ( | 37.3% ( | 31.7% ( | |
| - endocarditis | 19.8% ( | 24.4% ( | 12.6% ( | |
| - not documented | 0.7% ( | 1.0% ( | 0.4% ( | |
| lead dysfunction | 39.4% ( | 35.6% ( | 45.4% ( | 0.012 |
| - lead failure | 32.5% ( | 28.9% ( | 38.2% ( | |
| - lead interference | 3.1% ( | 0.7% ( | 6.9% ( | |
| - recall (sprint fidelis) | 3.4% ( | 5.7% ( | 0% ( | |
| - recall (riata) | 0.1% ( | 0.2% ( | 0% ( | |
| - dislocation | 0.1% ( | 0% ( | 0.4% ( | |
| other | 6.4% ( | 3.1% ( | 11.3% ( | <0.001 |
| - upgrade | 3.4% ( | 0.5% ( | 7.7% ( | |
| - haematoma | 0.1% ( | 0.1% ( | 0% ( | |
| - removal of lead stub | 0.1% ( | 0% ( | 0.4% ( | |
| - not documented | 2.7% ( | 2.3% ( | 3.3% ( |
Multiple indications for TLE were possible. TLE: transvenous lead extraction. ICD: implantable cardioverter defibrillator; CRT: cardiac resynchronization therapy; PM: pacemaker; DCM: dilated cardiomyopathy; ICM: ischemic cardiomyopathy; SSS: sick sinus syndrome; VT/VF: ventricular tachycardia/fibrillation.
Lead details. RA: right atrium; RV: right ventricle; ICD: implantable cardioverter-defibrillator; LV: left ventricle.
| Total | ICD | non-ICD | ||
|---|---|---|---|---|
| 484 | 310 | 174 | 0.002 | |
| lead dwell time (months) | 73.3 (38.9–111.4) | 73.8 (40.9–109.0) | 70.3 (32.0–119.4) | 0.942 |
| active fixation | 28.5% ( | 31% ( | 24.1% ( | 0.090 |
| 443 | 443 | 0 | <0.001 | |
| lead dwell time (months) | 59.1 (31.6–92.4) | 59.1 (31.6–92.4) | N/A | N/A |
| dual coils | 45.1% ( | 45.1% ( | N/A | N/A |
| active fixation | 49.4% ( | 49.4% ( | N/A | N/A |
| 279 | 56 | 223 | <0.001 | |
| lead dwell time (months) | 77.0 (34.3–153.8) | 120.4 (86.1–164.9) | 62.45 (28.3–134.1) | <0.001 |
| active fixation | 31.5% ( | 30.4% ( | 31.8% ( | 0.872 |
| 223 | 181 | 42 | <0.001 | |
| lead dwell time (months) | 52.2 (28.9–82.5) | 54.6 (28.9–84.4) | 43.5 (28.4–69.5) | 0.179 |
| active fixation | 2.7% ( | 2.2% ( | 4.8% ( | 0.323 |
| 1430 | 991 | 439 | N/A | |
| lead dwell time (months) | 64.6 (33.9–104.1) | 66.9 (35.6–100.1) | 61.5 (30.1–109.4) | 0.681 |
| active fixation | 31.5% ( | 33.9% ( | 26.2% ( | <0.001 |
RA: right atrium; RV: right ventricle; ICD: implantable cardioverter-defibrillator; LV: left ventricle.
Extraction techniques used for successful lead explant.
| Step | Total | ICD | non-ICD | |
|---|---|---|---|---|
|
| 100% ( | 100% ( | 100% ( | N/A |
| Use of regular stylet | 28.2% ( | 27.9% ( | 28.6% ( | 0.860 |
| Use of locking stylet | 26.1% ( | 26.9% ( | 24.8% ( | 0.588 |
| Complete retrieval (step 1) | 35.7% ( | 22.5% ( | 56.1% ( | <0.001 |
|
| 2.4% ( | 3.0% ( | 1.5% ( | 0.305 |
| Complete retrieval (steps 1–2) | 37.3% ( | 24.7% ( | 56.9% ( | <0.001 |
|
| 59.2% ( | 73.3% ( | 37.4% ( | <0.001 |
| Use of Mechanical sheaths | 58.9% ( | 73.3% ( | 36.6% ( | <0.001 |
| TightRail, Spectanetrics | 6.1% ( | 6.2% ( | 6.1% ( | 1.000 |
| Evolution RL, Cook Medical | 58.3% ( | 72.6% ( | 36.3% ( | <0.001 |
| Use of Laser sheaths—SLS II, Spectanetrics | 27.0% ( | 33.3% ( | 17.2% ( | <0.001 |
| Complete retrieval (steps 1–3) | 84.6% ( | 84.7% ( | 84.4% ( | 1.000 |
|
| 11.8% ( | 12.6% ( | 10.7% ( | 0.540 |
| Complete retrieval (steps 1–4) | 94.8% ( | 95.8% ( | 93.1% ( | 0.286 |
|
| 0.3% ( | 0.2% ( | 0.4% ( | 1.000 |
| Surgical removal | 0.1% ( | 0.0% ( | 0.4% ( | 0.391 |
| Primary abandoning | 0.1% ( | 0.2% ( | 0.0% ( | 1.000 |
| Complete retrieval | 50.0% ( | 0.0% ( | 100.0% ( | 1.000 |
|
| ||||
| Complete removal | 94.9% ( | 95.8% ( | 93.5% ( | 0.369 |
| Clinical success | 99.0% ( | 98.8% ( | 99.2% ( | 0.256 |
| Lead abandoned/failed TLE | 1.0% ( | 1.2% ( | 0.8% ( | 0.256 |
|
| 4.0% ( | 4.7% ( | 3.1% ( | 0.421 |
| Major intraprocedural complication | 0.7% ( | 0.7% ( | 0.8% ( | 1.000 |
| Any intraprocedural complication | 2.1% ( | 2.2% ( | 1.9% ( | 1.000 |
| Intraprocedural death | 0.1% ( | 0.2% ( | 0% ( | 1.000 |
| Postprocedural complication | 1.9% ( | 2.5% ( | 1.1% ( | 0.267 |
| Postprocedural death | 0.1% ( | 0.2% ( | 0% ( | 1.000 |
TLE: transvenous lead extraction.
Predictors for short-term complications.
| Parameter | Procedures with Complications | Procedures without Complications | |
|---|---|---|---|
|
| |||
| number of implanted leads | 2.8 ± 1.2 | 2.4 ± 0.8 | 0.015 |
| duration from lead implantation (years) | 9.5 ± 6.3 | 6.7 ± 5.2 | 0.014 |
| use of complex extraction tools (steps 2–3) | 85.2% | 60.9% | 0.019 |
|
| |||
| MB score | 4.5 ± 1.3 | 3.7 ± 1.4 | 0.005 |
| SAFeTY TLE score | 0.75 ± 0.64% | 0.47 ± 0.46% | 0.039 |
TLE: transvenous lead extraction.