We compared objective Double-Pass (DP) image quality data with subjective visual parameters measured within the same modified instrument for different amounts of scatter. The original DP imaging channel of a clinical instrument was maintained intact and two additional channels were included, one for visual testing and another for tear film (TF) imaging by using a retro-illumination technique. Contrast sensitivity (CS) was compared with measurements of the Objective Scattering Index (OSI) obtained from DP retinal images corresponding to different scatter levels induced by pre-defined filters. OSI values were correlated with the change in CS for different spatial frequencies measured with the same instrument. Since TF and DP images were recorded at the same rate, this provided additional information about the dynamic spatial stability of the tear film. This new DP instrument has been proven to provide accuracy and repeatability, and to be suitable for clinical diagnosis, with a complete evaluation of the eye's performance by a simultaneous objective and subjective assessment under the same experimental conditions.

Entities:  

Keywords:  (330.4460) Ophthalmic optics and devices; (330.7327) Visual optics, ophthalmic instrumentation

Year:  2015        PMID: 26713198      PMCID: PMC4679258          DOI: 10.1364/BOE.6.004841

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  13 in total

1.  Dynamics of the eye's wave aberration.

Authors:  H Hofer; P Artal; B Singer; J L Aragón; D R Williams
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-03       Impact factor: 2.129

2.  Use of retroillumination to visualize optical aberrations caused by tear film break-up.

Authors:  Nikole L Himebaugh; Annette R Wright; Arthur Bradley; Carolyn G Begley; Larry N Thibos
Journal:  Optom Vis Sci       Date:  2003-01       Impact factor: 1.973

3.  Retinal-image quality and contrast-sensitivity function in age-related macular degeneration.

Authors:  Carolina Ortiz; José R Jiménez; Francisco Pérez-Ocón; José J Castro; Rosario González-Anera
Journal:  Curr Eye Res       Date:  2010-08       Impact factor: 2.424

4.  Determination of the point-spread function of human eyes using a hybrid optical-digital method.

Authors:  J Santamaría; P Artal; J Bescós
Journal:  J Opt Soc Am A       Date:  1987-06       Impact factor: 2.129

5.  Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument.

Authors:  Fernando Díaz-Doutón; Antonio Benito; Jaume Pujol; Montserrat Arjona; José Luis Güell; Pablo Artal
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-04       Impact factor: 4.799

6.  Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.

Authors:  Antonio Benito; Guillermo M Pérez; Sandra Mirabet; Meritxell Vilaseca; Jaume Pujol; José M Marín; Pablo Artal
Journal:  J Cataract Refract Surg       Date:  2011-08       Impact factor: 3.351

7.  Use of the double-pass technique to quantify ocular scatter in patients with uveitis: a pilot study.

Authors:  Mayank A Nanavaty; Miles R Stanford; Rohit Sharma; Anish Dhital; David J Spalton; John Marshall
Journal:  Ophthalmologica       Date:  2010-08-14       Impact factor: 3.250

8.  Optical quality one month after verisyse and Veriflex phakic IOL implantation and Zeiss MEL 80 LASIK for myopia from 5.00 to 16.50 diopters.

Authors:  Meritxell Vilaseca; Adenay Padilla; Jaume Pujol; Juan C Ondategui; Pablo Artal; Jose L Güell
Journal:  J Refract Surg       Date:  2009-08       Impact factor: 3.573

9.  Effect of laser in situ keratomileusis on vision analyzed using preoperative optical quality.

Authors:  Meritxell Vilaseca; Adenay Padilla; Juan C Ondategui; Montserrat Arjona; José L Güell; Jaume Pujol
Journal:  J Cataract Refract Surg       Date:  2010-11       Impact factor: 3.351

10.  Compact optical integration instrument to measure intraocular straylight.

Authors:  Harilaos Ginis; Onurcan Sahin; Alexandros Pennos; Pablo Artal
Journal:  Biomed Opt Express       Date:  2014-08-14       Impact factor: 3.732

View more
  4 in total

1.  Effect of higher-order aberrations and intraocular scatter on contrast sensitivity measured with a single instrument.

Authors:  Junlei Zhao; Fei Xiao; Haoxin Zhao; Yun Dai; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2017-03-09       Impact factor: 3.732

2.  Binocular summation and visual function with induced anisocoria and monovision.

Authors:  José J Castro; Margarita Soler; Carolina Ortiz; José R Jiménez; Rosario G Anera
Journal:  Biomed Opt Express       Date:  2016-09-23       Impact factor: 3.732

3.  Speckle reduction in double-pass retinal images.

Authors:  Donatus Halpaap; Carlos E García-Guerra; Meritxell Vilaseca; Cristina Masoller
Journal:  Sci Rep       Date:  2019-03-14       Impact factor: 4.379

4.  Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses.

Authors:  Lingying Ye; Tianyu Chen; Zhixiang Hu; Qingwen Yang; Qiudong Su; Jin Li
Journal:  Ann Transl Med       Date:  2021-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.