Literature DB >> 28663835

Performance of a differential contrast sensitivity method to measure intraocular scattering.

Alexandros Pennos1, Harilaos Ginis1,2, Augusto Arias1, Dimitrios Christaras1,3, Pablo Artal1.   

Abstract

Increased intraocular scatter degrades quality of vision, especially in the presence of glare sources. Standard tests, such as visual acuity, are not well suited to capture this condition. There are specific methods to measure intraocular scatter, but require dedicated instruments. In this work, we propose a method to estimate the amount of scatter by combining to sequential measurements of the contrast sensitivity function for two conditions, with and without a glare source. We applied the approach in a group of young subjects with no know ocular pathology fitted with photographic diffusing filters. The straylight estimates were compared with those provided by two alternative techniques, one based on the compensation comparison method and the other the optical integration. The results obtained with the three approaches were in a good agreement, demonstrating the feasibility of the proposed method.

Keywords:  (290.2648) Stray light; (290.5820) Scattering measurements; (330.4460) Ophthalmic optics and devices; (330.5370) Physiological optics

Year:  2017        PMID: 28663835      PMCID: PMC5480550          DOI: 10.1364/BOE.8.001382

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  26 in total

1.  Compensation comparison method for assessment of retinal straylight.

Authors:  Luuk Franssen; Joris E Coppens; Thomas J T P van den Berg
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-02       Impact factor: 4.799

2.  Psychophysics, reliability, and norm values for temporal contrast sensitivity implemented on the two alternative forced choice C-Quant device.

Authors:  Thomas J T P van den Berg; Luuk Franssen; Bastiaan Kruijt; Joris E Coppens
Journal:  J Biomed Opt       Date:  2011-08       Impact factor: 3.170

3.  Wavelength dependence of the ocular straylight.

Authors:  Harilaos S Ginis; Guillermo M Perez; Juan M Bueno; Alexandros Pennos; Pablo Artal
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-05-01       Impact factor: 4.799

4.  Analysis of intraocular straylight, especially in relation to age.

Authors:  T J van den Berg
Journal:  Optom Vis Sci       Date:  1995-02       Impact factor: 1.973

5.  Contrast sensitivity in the presence of a glare light. Theoretical concepts and preliminary clinical studies.

Authors:  L E Paulsson; J Sjöstrand
Journal:  Invest Ophthalmol Vis Sci       Date:  1980-04       Impact factor: 4.799

6.  Vision through cataracts.

Authors:  R Hess; G Woo
Journal:  Invest Ophthalmol Vis Sci       Date:  1978-05       Impact factor: 4.799

7.  Optical Measurement of Straylight in Eyes With Cataract.

Authors:  Onurcan Sahin; Alexandros Pennos; Harilaos Ginis; Lucia Hervella; Eloy A Villegas; Belen Cañizares; Jose Maria Marin; Ioannis Pallikaris; Pablo Artal
Journal:  J Refract Surg       Date:  2016-12-01       Impact factor: 3.573

8.  Straylight and Visual Quality on Early Nuclear and Posterior Subcapsular Cataracts.

Authors:  Clemente Paz Filgueira; Roberto F Sánchez; Luis A Issolio; Elisa M Colombo
Journal:  Curr Eye Res       Date:  2016-01-14       Impact factor: 2.424

9.  Compact optical integration instrument to measure intraocular straylight.

Authors:  Harilaos Ginis; Onurcan Sahin; Alexandros Pennos; Pablo Artal
Journal:  Biomed Opt Express       Date:  2014-08-14       Impact factor: 3.732

10.  The case for using the repeatability coefficient when calculating test-retest reliability.

Authors:  Sharmila Vaz; Torbjörn Falkmer; Anne Elizabeth Passmore; Richard Parsons; Pantelis Andreou
Journal:  PLoS One       Date:  2013-09-09       Impact factor: 3.240

View more
  3 in total

1.  System based on the contrast of Purkinje images to measure corneal and lens scattering.

Authors:  Pau Santos; Juan A Martínez-Roda; Juan C Ondategui; Fernando Díaz-Doutón; Jorge A Ortiz Cazal; Meritxell Vilaseca
Journal:  Biomed Opt Express       Date:  2018-09-18       Impact factor: 3.732

2.  The effects of two longpass filters on visual performance.

Authors:  Federica Cozza; Matteo Monzio Compagnoni; Chiara Airoldi; Chiara Braga; Gabriele Nigrotti; Natalia Vlasak; Silvano Larcher; Fabrizio Zeri; Silvia Tavazzi
Journal:  J Optom       Date:  2019-10-18

3.  The Effect of Capsulotomy Shape on Intraocular Light-Scattering after Nd:YAG Laser Capsulotomy.

Authors:  Jun Li; Zhe Yu; Hui Song
Journal:  J Ophthalmol       Date:  2020-03-23       Impact factor: 1.909

  3 in total