Abstract

The rigidity, load to yield, and load to failure of ten configurations of the Hoffmann external fixator were investigated using a model of wooden pylons with a simulated fracture that consisted of either a reduced transverse cut or a ten-millimeter gap. The axial compressive, torsional, anterior-posterior bending, and medial-lateral bending characteristics of four forms of the single half-frame (half-pinned), four double half-frame, and two full-frame (transfixion-pinned) configurations were examined. Of the single half-frame configurations, a system with a second stacked connecting-rod proved to be superior; however, the system yielded at a mean axial compressive load of only 199 newtons and failed totally at 355 newtons. The delta frame (two rods connecting or triangulating two half-frames set at an angle of 45 degrees to one another) was as rigid as the quadrilateral full frame in axial compression; however, it exhibited low loads to yield and to failure, with means around 200 and 350 newtons, respectively. The use of only two pins in each pin-cluster did not significantly affect the performance of the delta frame. The two full-frame systems performed poorly in torsion and particularly poorly in anterior-posterior bending. The loads that caused a one-millimeter movement within the fracture gap in axial compression were notably low: for the stacked half-frames the load did not exceed a mean value of 174 newtons; for the double half-frame, 190 newtons; and for the quadrilateral frame, 412 newtons. We concluded that no frame had a good over-all performance with regard to rigidity.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1987        PMID: 3597473

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  13 in total

1.  Hoffmann half-frame external fixation rigidity and its relationship to universal joint slippage.

Authors:  F L Drijber; J B Finlay
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

2.  Effects of construct stiffness on healing of fractures stabilized with locking plates.

Authors:  Michael Bottlang; Josef Doornink; Trevor J Lujan; Daniel C Fitzpatrick; J Lawrence Marsh; Peter Augat; Brigitte von Rechenberg; Maren Lesser; Steven M Madey
Journal:  J Bone Joint Surg Am       Date:  2010-12       Impact factor: 5.284

3.  Supplementary delta-rod configurations provide superior stiffness and reduced rod stress compared to traditional multiple-rod configurations after pedicle subtraction osteotomy: a finite element study.

Authors:  Pedro Berjano; Ming Xu; Marco Damilano; Thomas Scholl; Claudio Lamartina; Michael Jekir; Fabio Galbusera
Journal:  Eur Spine J       Date:  2019-05-25       Impact factor: 3.134

4.  Source of the slippage in the universal joints of the Hoffmann external fixator.

Authors:  F L Drijber; J B Finlay; T K Moroz; C H Rorabeck
Journal:  Med Biol Eng Comput       Date:  1990-01       Impact factor: 2.602

5.  Structural stiffness of the Hoffmann simple anterior tibial external fixation frame.

Authors:  J Vossoughi; Y Youm; M Bosse; A R Burgess; A Poka
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

6.  Stability of the original Hoffman and AO tubular external fixation devices.

Authors:  T K Moroz; J B Finlay; C H Rorabeck; R B Bourne
Journal:  Med Biol Eng Comput       Date:  1988-05       Impact factor: 2.602

Review 7.  Biomechanics of far cortical locking.

Authors:  Michael Bottlang; Florian Feist
Journal:  J Orthop Trauma       Date:  2011-02       Impact factor: 2.512

8.  Experimental analysis of effects of pin pretensioning on external fixator rigidity.

Authors:  J Doyle; P Hayes; G Fenlon
Journal:  Arch Orthop Trauma Surg       Date:  1988

9.  Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes.

Authors:  Christopher E Henderson; Michael Bottlang; J Lawrence Marsh; Dan C Fitzpatrick; Steven M Madey
Journal:  Iowa Orthop J       Date:  2008

10.  Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength.

Authors:  Michael Bottlang; Josef Doornink; Daniel C Fitzpatrick; Steven M Madey
Journal:  J Bone Joint Surg Am       Date:  2009-08       Impact factor: 5.284

View more