Literature DB >> 35942324

Digital templating in hip hemiarthroplasty: Is it possible to accurately predict femoral head size from magnification alone?

Daniel Thurston1, Saad El-Ashry1, Sreenadh Gella1, Kanthan Theivendran1.   

Abstract

Background: Templating is an integral part of pre-operative planning in elective hip arthroplasty to achieve favourable long-term outcomes, but its applications in trauma surgery remain limited. When templating from radiographs without a calibration marker, there is always an element of magnification which must be accounted for. Our aim was to establish our institute-specific magnification and to determine whether using this to predict femoral head size in hemiarthroplasty was more accurate than using set magnifications previously reported in the literature. Materials & methods: Fifty consecutive patients who underwent hip hemiarthroplasty were retrospectively identified, their pre-operative radiographs reviewed and femoral head measured with templating software. Intra- and inter-observer reliability analyses were performed. Using this value, and two set values of 15% and 21% magnification, we attempted to predict femoral head sizes of our original cohort. The results were compared using paired t-test to ascertain if there was any significant difference in accuracy.
Results: We established our institute-specific magnification as 17%. Inter- and intra-observer reliability were excellent. However, using this magnification we were only able to correctly predict to within ± one femoral head size in 49% of patients. There was no significant difference in accuracy comparing our institute-specific magnification with other magnifications from the literature.
Conclusion: We would not recommend using magnification factor in digital templating software as this could potentially lead to errors in predicting final femoral head size in hip hemiarthroplasty and adversely affect patient outcomes.
© 2022.

Entities:  

Keywords:  Hemiarthroplasty; Hip fracture; Templating; Trauma

Year:  2022        PMID: 35942324      PMCID: PMC9356085          DOI: 10.1016/j.jcot.2022.101952

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  17 in total

1.  Reliability of measurements with digital radiographs--a myth.

Authors:  Bobin Varghese; Nagarajan Muthukumar; Muthukumar Balasubramaniam; Andrew Scally
Journal:  Acta Orthop Belg       Date:  2011-10       Impact factor: 0.500

2.  Accuracy of digital templating in total hip arthroplasty.

Authors:  David R Whiddon; James V Bono; Jason E Lang; Eric L Smith; Aaron K Salyapongse
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2011-08

Review 3.  Preoperative planning for primary total hip arthroplasty.

Authors:  Alejandro González Della Valle; Douglas E Padgett; Eduardo A Salvati
Journal:  J Am Acad Orthop Surg       Date:  2005-11       Impact factor: 3.020

4.  Prospective, Randomized, Surgeon-Blinded Comparison of Standard Magnification Assumption vs Magnification Marker Usage for Preoperative Templating in Total Hip Arthroplasty.

Authors:  Michael J Archibeck; Krishna R Tripuraneni; Joshua T Carothers; Daniel W Junick; Natalie R Munson; Cristina M Murray-Krezan
Journal:  J Arthroplasty       Date:  2017-05-17       Impact factor: 4.757

5.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

6.  Preoperative sizing of hip hemiarthroplasties to accurately estimate head size from non- standardised pelvic radiographs: Can it be done?

Authors:  Sebastien Crosswell; Harold Akehurst; Reagon Ramiah; Basalingappa Navadgi
Journal:  Injury       Date:  2019-08-17       Impact factor: 2.586

7.  The accuracy of digital templating in uncemented total hip arthroplasty.

Authors:  Patrick Gamble; Justin de Beer; Danielle Petruccelli; Mitchell Winemaker
Journal:  J Arthroplasty       Date:  2009-06-02       Impact factor: 4.757

8.  The magnification of digital radiographs in the trauma patient: implications for templating.

Authors:  R J King; P R S Craig; B G Boreham; M A Majeed; C G Moran
Journal:  Injury       Date:  2008-12-17       Impact factor: 2.586

9.  Accuracy of preoperative templating in total hip arthroplasty.

Authors:  Andrew Riddick; Adam Smith; D Phill Thomas
Journal:  J Orthop Surg (Hong Kong)       Date:  2014-08       Impact factor: 1.118

10.  Digital templating in hip replacement with and without radiological markers.

Authors:  G Heinert; J Hendricks; M D Loeffler
Journal:  J Bone Joint Surg Br       Date:  2009-04
View more