Literature DB >> 19336804

Digital templating in hip replacement with and without radiological markers.

G Heinert1, J Hendricks, M D Loeffler.   

Abstract

Digital templating in hip replacement is commonly performed with radiological markers to determine the magnification. The latter can also be determined by measuring the distance from the x-ray focal spot to the object and the distance from the x-ray focal spot to the radiological cassette or image receptor. We used post-operative radiographs of total hip replacements and hemiarthroplasties from 22 patients to calculate the magnification using both methods. The accuracy of each method was ascertained by measuring the size of the head of the implant projected on to the radiographs and comparing the result with the known size recorded in the medical records. The accuracy was found to be similar with a mean absolute measurement error of 2.6% (SD 1.4; 0.0% to 5.2%) for the radiological marker and 2.8% (sd 2.2; 0.4% to 10.1%) for the distance method (p = 0.75). The mean radiation dose for templating radiographs (pelvis and lateral of the hip) was similar when taken using a radiological marker (328 mSv SD 142) (n = 51) or using the distance measurement method (324 mSv SD 39) (n = 39) (p = 0.90). We conclude that the distance measuring method is as accurate as the radiological marker method, but may avoid some of the disadvantages such as misplacement of the marker or placement outside the radiological field. It may also be more acceptable to the patient and radiographer.

Entities:  

Mesh:

Year:  2009        PMID: 19336804     DOI: 10.1302/0301-620X.91B4.21730

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

1.  Magnification error in digital radiographs of the cervical spine against magnetic resonance imaging measurements.

Authors:  Hideki Shigematsu; Munehisa Koizumi; Masana Yoneda; Jin Iida; Takuya Oshima; Yasuhito Tanaka
Journal:  Asian Spine J       Date:  2013-11-28

2.  Digital templating in hip hemiarthroplasty: Is it possible to accurately predict femoral head size from magnification alone?

Authors:  Daniel Thurston; Saad El-Ashry; Sreenadh Gella; Kanthan Theivendran
Journal:  J Clin Orthop Trauma       Date:  2022-07-16

3.  Acetabular positioning is more consistent with the use of a novel miniature computer-assisted device.

Authors:  Ivan Jacob; Jessica Benson; Kate Shanaghan; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2020-01-22       Impact factor: 3.075

4.  Calibration Markers for Digital Templating in Total Hip Arthroplasty.

Authors:  Christoph Kolja Boese; Philipp Lechler; Leonard Rose; Jens Dargel; Johannes Oppermann; Peer Eysel; Hansjörg Geiges; Jan Bredow
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

5.  Is it Important to Know Where to Place the Spherical Marker for Hip Replacement Digital Planning?

Authors:  Giancarlo Cavalli Polesello; Thiago Tronco Salerno; João Hélio Zucarelli Rezende; Marcelo Cavalheiro de Queiroz; Nayra Deise Rabelo; Walter Ricioli Junior
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2019-11-07

6.  The accuracy of digital templating in uncemented total hip arthroplasty.

Authors:  Lukas A Holzer; Georg Scholler; Stefan Wagner; Jörg Friesenbichler; Werner Maurer-Ertl; Andreas Leithner
Journal:  Arch Orthop Trauma Surg       Date:  2018-12-06       Impact factor: 3.067

7.  Is There Any Difference Between a Spherical Marker and a Simple Coin for Hip Replacement Digital Planning?

Authors:  Giancarlo Cavalli Polesello; Thiago Tronco Salerno; Marcelo Cavalheiro de Queiroz; Walter Ricioli Junior; Nayra Deise Anjos Rabelo; Emerson Kyioshi Honda
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2022-01-24

8.  Magnification of digital hip radiographs differs between clinical workplaces.

Authors:  Jana Hornová; Pavel Růžička; Maroš Hrubina; Eduard Šťastný; Andrea Košková; Petr Fulín; Jiří Gallo; Matej Daniel
Journal:  PLoS One       Date:  2017-11-30       Impact factor: 3.240

9.  Digital templating for the implantation of a curved short hip stem with an anterolateral MIS approach shows gender differences in digital templating.

Authors:  Matthias Luger; Rainer Hochgatterer; Matthias C Klotz; Günter Hipmair; Tobias Gotterbarm; Bernhard Schauer
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-24       Impact factor: 2.928

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.