Literature DB >> 19493647

The accuracy of digital templating in uncemented total hip arthroplasty.

Patrick Gamble1, Justin de Beer, Danielle Petruccelli, Mitchell Winemaker.   

Abstract

We analyzed the reproducibility and reliability of computer templating in primary uncemented total hip arthroplasties as compared to standard onlay templating techniques with hardcopy radiographs from a digital source. Digital templating showed good intraobserver and interoberserver reliability with intraclass correlation coefficient values greater than 0.7. Using computer templating, prediction of sizing to within 1 size was 85% accurate for femoral stem sizing and 80% accurate for acetabular sizing. Using onlay templating, prediction of sizing to within 1 size was 85% accurate for femoral sizing and 60% accurate for acetabular sizing. We conclude that the introduction of digital templating has significant benefits in preoperative planning for total hip arthroplasty over onlay templating. Crown Copyright 2010. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19493647     DOI: 10.1016/j.arth.2009.04.011

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  34 in total

1.  Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

Authors:  Vignesh P Krishnamoorthy; Rajamani Perumal; Alfred J Daniel; Pradeep M Poonnoose
Journal:  J Clin Orthop Trauma       Date:  2015-05-11

2.  Inaccuracies in the Use of Magnification Markers in Digital Hip Radiographs.

Authors:  Michael J Archibeck; Tamara Cummins; Krishna R Tripuraneni; Joshua T Carothers; Cristina Murray-Krezan; Mohammad Hattab; Richard E White
Journal:  Clin Orthop Relat Res       Date:  2016-01-21       Impact factor: 4.176

3.  Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system.

Authors:  Ari Bertz; Kari Indrekvam; Mohamed Ahmed; Erling Englund; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2012-05-16       Impact factor: 2.199

4.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

5.  Radiographic templating of total hip arthroplasty for femoral neck fractures.

Authors:  Dror Lakstein; Ira Bachar; Ronen Debi; Omri Lubovsky; Ornit Cohen; Zachary Tan; Ehud Atoun
Journal:  Int Orthop       Date:  2016-06-07       Impact factor: 3.075

6.  CORR Insights(®): acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2015-05-27       Impact factor: 4.176

7.  Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement.

Authors:  Junwei Li; Xu Gao; Guanghui Yang; Yanru Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

8.  Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience.

Authors:  Nils J Strøm; Are Hugo Pripp; Olav Reikerås
Journal:  Ann Transl Med       Date:  2017-02

9.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

10.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.