Analysis of the morphometric characteristics of the thoracic and lumbar pedicles.

M R Zindrick, L L Wiltse, A Doornik, E H Widell, G W Knight, A G Patwardhan, J C Thomas, S L Rothman, B T Fields.   

Abstract

A total of 2,905 pedicle measurements were made from T1-L5. Measurements were made from spinal computerized tomography (CT) scan examinations and individual vertebral specimen roentgenograms. Parameters considered were the pedicle isthmus width in the transverse and sagittal planes, pedicle angles in the transverse and sagittal planes, and the depth to the anterior cortex in a line parallel to the midline of the vertebral body and along the pedicle axis. There was no significant difference between data obtained from CT scans and specimen roentgenograms. Pedicles were widest at L5 and narrowest at T5 in the transverse plane. The widest pedicles in the sagittal plane were seen at T11, the narrowest at T1. Due to the oval shape of the pedicle, the sagittal plane width was generally larger than the transverse plane width. The largest pedicle angle in the transverse plane was at L5. The posterolateral to anterolateral pedicle axis orientation in the transverse plane, seen at other levels throughout the thoracolumbar spine, reversed at T12. In the sagittal plane, the pedicles angled caudally at L5 and cephaladly from L3-T1. The depth to the anterior cortex was significantly longer along the pedicle axis than along a line parallel to the midline of the vertebral body at all levels with the exception of T12 and T11.

Entities:  

Mesh:

Year:  1987        PMID: 3589807     DOI: 10.1097/00007632-198703000-00012

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  104 in total

1.  Biomechanical evaluation of a bipedicular spinal fixation device: three different strength tests.

Authors:  Laurent Balabaud; Emeric Gallard; Wafa Skalli; Bernard Dupas; Robert Roger; François Lavaste; Jean-Paul Steib
Journal:  Eur Spine J       Date:  2003-04-05       Impact factor: 3.134

2.  Measurements of the lumbar pedicles in the Eastern Anatolian population.

Authors:  H H Kadioglu; E Takci; A Levent; M Arik; I H Aydin
Journal:  Surg Radiol Anat       Date:  2003-05-14       Impact factor: 1.246

3.  Quantitative three-dimensional anatomy of cervical, thoracic and lumbar vertebrae of Chinese Singaporeans.

Authors:  S H Tan; E C Teo; H C Chua
Journal:  Eur Spine J       Date:  2003-12-12       Impact factor: 3.134

4.  [Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae].

Authors:  K Wendl; J von Recum; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

5.  [Intraoperative three-dimensional navigation for pedicle screw placement].

Authors:  P A Grützner; T Beutler; K Wendl; J von Recum; A Wentzensen; L-P Nolte
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

6.  [Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique].

Authors:  K J Schnake; B König; U Berth; R J Schroeder; F Kandziora; U Stöckle; M Raschke; N P Haas
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

7.  Analysis of lumbar pedicle morphology in degenerative spines using multiplanar reconstruction computed tomography: what can be the reliable index for optimal pedicle screw diameter?

Authors:  Takahiro Makino; Takashi Kaito; Hiroyasu Fujiwara; Kazuo Yonenobu
Journal:  Eur Spine J       Date:  2012-02-19       Impact factor: 3.134

8.  Comparison of radiographic and computed tomographic measurement of pedicle and vertebral body dimensions in Koreans: the ratio of pedicle transverse diameter to vertebral body transverse diameter.

Authors:  Ki Ser Kang; Kwang-Sup Song; Jong Seok Lee; Jae Jun Yang; In Sup Song
Journal:  Eur Spine J       Date:  2010-08-30       Impact factor: 3.134

9.  Thoracic pedicle screw insertion in Asian cadaveric specimen: does radiological pedicle profile affect outcome?

Authors:  Chris Yin Wei Chan; Mun Keong Kwan; Lim Beng Saw
Journal:  Surg Radiol Anat       Date:  2010-09-17       Impact factor: 1.246

10.  Inserting pedicle screws in lumbar spondylolisthesis - The easy bone conserving way.

Authors:  Hitesh Lal; Lalit Kumar; Ramesh Kumar; Tankeshwar Boruah; Pankaj Kumar Jindal; Vinod Kumar Sabharwal
Journal:  J Clin Orthop Trauma       Date:  2017-03-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.