Literature DB >> 3587135

Scatter estimation for a digital radiographic system using convolution filtering.

L A Love, R A Kruger.   

Abstract

The use of a convolution-filtering method to estimate the scatter distribution in images acquired with a digital subtraction angiography (DSA) imaging system has been studied. Investigation of more than 175 convolution kernels applied to images of anthropomorphic head, chest, and pelvic phantoms using 15-, 25-, and 36-cm fields of view (digitized onto a 512 X 512 pixel image matrix) showed that two-dimensional exponential kernels with a full width at half maximum (FWHM) of 50-150 pixels best reproduced the scatter fields within these images with a root-mean-square percentage error from 4% to 8%. A two-dimensional exponential kernal with a FWHM of 75 pixels in each dimension applied to ten different anatomic presentations and fields of view, resulted in an average root-mean-square percentage error of 6.6% for the ten cases studied. The method should be implementable using an array of small lead beam stops placed in the field of only a single mask image and the above described convolution kernel applied to both mask and postopacification images. The mask beam-stop data are used to scale both mask and postopacification convolution-filtered images. This scaled, convolution-filtered image is then subtracted from the original image to produce a largely scatter-corrected image.

Mesh:

Year:  1987        PMID: 3587135     DOI: 10.1118/1.596126

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

2.  Characterization of X-ray scattering for various phantoms and clinical breast geometries using breast CT on a dedicated hybrid system.

Authors:  Jainil P Shah; Steve D Mann; Martin P Tornai
Journal:  J Xray Sci Technol       Date:  2017       Impact factor: 1.535

3.  Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT).

Authors:  Mingshan Sun; Tamás Nagy; Gary Virshup; Larry Partain; Markus Oelhafen; Josh Star-Lack
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Scatter correction method for x-ray CT using primary modulation: phantom studies.

Authors:  Hewei Gao; Rebecca Fahrig; N Robert Bennett; Mingshan Sun; Josh Star-Lack; Lei Zhu
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

5.  Robust primary modulation-based scatter estimation for cone-beam CT.

Authors:  Ludwig Ritschl; Rebecca Fahrig; Michael Knaup; Joscha Maier; Marc Kachelrieß
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

6.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

7.  Learning-based CBCT correction using alternating random forest based on auto-context model.

Authors:  Yang Lei; Xiangyang Tang; Kristin Higgins; Jolinta Lin; Jiwoong Jeong; Tian Liu; Anees Dhabaan; Tonghe Wang; Xue Dong; Robert Press; Walter J Curran; Xiaofeng Yang
Journal:  Med Phys       Date:  2018-12-11       Impact factor: 4.071

8.  Dual-Energy Technique at Low Tube Voltages for Small Animal Imaging.

Authors:  Seungryong Cho; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

9.  Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

Authors:  Alexander Maslowski; Adam Wang; Mingshan Sun; Todd Wareing; Ian Davis; Josh Star-Lack
Journal:  Med Phys       Date:  2018-04-06       Impact factor: 4.071

Review 10.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.