Characterization of X-ray scattering for various phantoms and clinical breast geometries using breast CT on a dedicated hybrid system.

Jainil P Shah1,2, Steve D Mann2,3, Martin P Tornai1,2,3.   

Abstract

OBJECTIVE: The purpose of this study was to utilize a dedicated breast CT system using a 2D beam stop array to physically evaluate the scatter to primary ratios (SPRs) of different geometric phantoms and prospectively acquired clinical patient data.
METHODS: Including clinically unrealizable compositions of 100% glandular and 100% fat, projection images were acquired using three geometrically different phantoms filled with fluids simulating breast tissue. The beam stop array method was used for measuring scatter in projection space, and creating the scatter corrected primary images. 2D SPRs were calculated. Additionally, a new figure of merit, the 3D normalized scatter contribution (NSC) volumes were calculated.
RESULTS: The 2D SPR values (0.52-1.10) were primarily dependent on phantom geometry; a secondary dependence was due to their uniform density; 2D SPRs were low frequency and smoothly varying in the uniformly filled phantoms. SPRs of clinical patient data followed similar trends as phantoms, but with noticeable deviations and high frequency components due to the heterogeneous distribution of glandular tissue. The maximum measured patient 2D SPRs were all <0.6, even for the largest diameter breast. These results demonstrate modest scatter components with changing object geometries and densities; the 3D NSC volumes with higher frequency components help visualize scatter distribution throughout the reconstructed image volumes. Furthermore, the SPRs in the heterogeneous clinical breast cases were underestimated by the equivalent density, uniformly filled phantoms.
CONCLUSIONS: These results provide guidance on the use of uniformly distributed density and differently shaped phantoms when considering simulations. They also clearly demonstrate that results from patients can vary considerably from 2D SPRs of uniformly simulated phantoms.

Entities:  

Keywords:  Mammotomography; beam stop array; breast CT; scatter correction; scatter-to-primary ratio

Mesh:

Year:  2017        PMID: 28157120      PMCID: PMC6022823          DOI: 10.3233/XST-16202

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  26 in total

1.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

2.  Ordered subset reconstruction for x-ray CT.

Authors:  F J Beekma; C Kamphuis
Journal:  Phys Med Biol       Date:  2001-07       Impact factor: 3.609

3.  X-ray scatter correction algorithm for cone beam CT imaging.

Authors:  Ruola Ning; Xiangyang Tang; David Conover
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

4.  Grids or air gaps for scatter reduction in digital radiography: a model calculation.

Authors:  U Neitzel
Journal:  Med Phys       Date:  1992 Mar-Apr       Impact factor: 4.071

5.  Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography.

Authors:  D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

6.  X-ray scatter correction method for dedicated breast computed tomography.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

7.  Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

Authors:  Dominic J Crotty; Samuel L Brady; D'Vone C Jackson; Greta I Toncheva; Colin E Anderson; Terry T Yoshizumi; Martin P Tornai
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

8.  Scatter estimation for a digital radiographic system using convolution filtering.

Authors:  L A Love; R A Kruger
Journal:  Med Phys       Date:  1987 Mar-Apr       Impact factor: 4.071

9.  The effects of scatter in x-ray computed tomography.

Authors:  P M Joseph; R D Spital
Journal:  Med Phys       Date:  1982 Jul-Aug       Impact factor: 4.071

10.  Snapshot 2D tomography via coded aperture x-ray scatter imaging.

Authors:  Kenneth P MacCabe; Andrew D Holmgren; Martin P Tornai; David J Brady
Journal:  Appl Opt       Date:  2013-07-01       Impact factor: 1.980

View more
  3 in total

1.  Characterization of CT Hounsfield Units for 3D acquisition trajectories on a dedicated breast CT system.

Authors:  Jainil P Shah; Steve D Mann; Randolph L McKinley; Martin P Tornai
Journal:  J Xray Sci Technol       Date:  2018       Impact factor: 1.535

2.  Radiation dosimetry of a clinical prototype dedicated cone-beam breast CT system with offset detector.

Authors:  Hsin Wu Tseng; Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2021-01-26       Impact factor: 4.506

3.  Analytical expressions for the reconstructed image of a homogeneous cylindrical sample exhibiting a beam hardening artifact in X-ray computed tomography.

Authors:  Tsukasa Nakano; Yoshito Nakashima
Journal:  J Xray Sci Technol       Date:  2018       Impact factor: 1.535

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.