Literature DB >> 25563286

Robust primary modulation-based scatter estimation for cone-beam CT.

Ludwig Ritschl1, Rebecca Fahrig2, Michael Knaup3, Joscha Maier3, Marc Kachelrieß3.   

Abstract

PURPOSE: Scattered radiation is one of the major problems facing image quality in flat detector cone-beam computed tomography (CBCT). Previously, a new scatter estimation and correction method using primary beam modulation has been proposed. The original image processing technique used a frequency-domain-based analysis, which proved to be sensitive to the accuracy of the modulator pattern both spatially and in amplitude as well as to the frequency of the modulation pattern. In addition, it cannot account for penumbra effects that occur, for example, due to the finite focal spot size and the scatter estimate can be degraded by high-frequency components of the primary image.
METHODS: In this paper, the authors present a new way to estimate the scatter using primary modulation. It is less sensitive to modulator nonidealities and most importantly can handle arbitrary modulator shapes and changes in modulator attenuation. The main idea is that the scatter estimation can be expressed as an optimization problem, which yields a separation of the scatter and the primary image. The method is evaluated using simulated and experimental CBCT data. The scattering properties of the modulator itself are analyzed using a Monte Carlo simulation.
RESULTS: All reconstructions show strong improvements of image quality. To quantify the results, all images are compared to reference images (ideal simulations and collimated scans).
CONCLUSIONS: The proposed modulator-based scatter reduction algorithm may open the field of flat detector-based imaging to become a quantitative modality. This may have significant impact on C-arm imaging and on image-guided radiation therapy.

Mesh:

Year:  2015        PMID: 25563286      PMCID: PMC4443800          DOI: 10.1118/1.4903261

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  Efficient object scatter correction algorithm for third and fourth generation CT scanners.

Authors:  B Ohnesorge; T Flohr; K Klingenbeck-Regn
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

2.  Modulator design for x-ray scatter correction using primary modulation: material selection.

Authors:  Hewei Gao; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  Scatter correction method for X-ray CT using primary modulation: theory and preliminary results.

Authors:  Lei Zhu; N Robert Bennett; Rebecca Fahrig
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

4.  Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT.

Authors:  Yiannis Kyriakou; Thomas Riedel; Willi A Kalender
Journal:  Phys Med Biol       Date:  2006-08-30       Impact factor: 3.609

5.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

6.  A fast and pragmatic approach for scatter correction in flat-detector CT using elliptic modeling and iterative optimization.

Authors:  Michael Meyer; Willi A Kalender; Yiannis Kyriakou
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

7.  Scatter estimation for a digital radiographic system using convolution filtering.

Authors:  L A Love; R A Kruger
Journal:  Med Phys       Date:  1987 Mar-Apr       Impact factor: 4.071

8.  X-ray scatter removal by deconvolution.

Authors:  J A Seibert; J M Boone
Journal:  Med Phys       Date:  1988 Jul-Aug       Impact factor: 4.071

9.  Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT.

Authors:  M Kachelriess; O Watzke; W A Kalender
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

10.  A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT.

Authors:  J H Siewerdsen; M J Daly; B Bakhtiar; D J Moseley; S Richard; H Keller; D A Jaffray
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

View more
  7 in total

1.  Estimating scatter from sparsely measured primary signal.

Authors:  Gongting Wu; Christina R Inscoe; Jabari Calliste; Jing Shan; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-29

2.  Local filtration based scatter correction for cone-beam CT using primary modulation.

Authors:  Lei Zhu
Journal:  Med Phys       Date:  2016-11       Impact factor: 4.071

3.  A model-based scatter artifacts correction for cone beam CT.

Authors:  Wei Zhao; Don Vernekohl; Jun Zhu; Luyao Wang; Lei Xing
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

4.  Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Authors:  Xi Chen; Luo Ouyang; Hao Yan; Xun Jia; Bin Li; Qingwen Lyu; You Zhang; Jing Wang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

5.  Evaluation and Clinical Application of a Commercially Available Iterative Reconstruction Algorithm for CBCT-Based IGRT.

Authors:  Weihua Mao; Chang Liu; Stephen J Gardner; Farzan Siddiqui; Karen C Snyder; Akila Kumarasiri; Bo Zhao; Joshua Kim; Ning Winston Wen; Benjamin Movsas; Indrin J Chetty
Journal:  Technol Cancer Res Treat       Date:  2019-01-01

6.  Contextual loss based artifact removal method on CBCT image.

Authors:  Shipeng Xie; Yingjuan Liang; Tao Yang; Zhenrong Song
Journal:  J Appl Clin Med Phys       Date:  2020-11-02       Impact factor: 2.102

Review 7.  Spectral Photon-Counting CT Technology in Chest Imaging.

Authors:  Salim Aymeric Si-Mohamed; Jade Miailhes; Pierre-Antoine Rodesch; Sara Boccalini; Hugo Lacombe; Valérie Leitman; Vincent Cottin; Loic Boussel; Philippe Douek
Journal:  J Clin Med       Date:  2021-12-09       Impact factor: 4.241

  7 in total