PURPOSE: Attenuation correction is a critically important step in data correction in positron emission tomography (PET) image formation. The current standard method involves conversion of Hounsfield units from a computed tomography (CT) image to construct attenuation maps (µ-maps) at 511 keV. In this work, the increased sensitivity of long axial field-of-view (LAFOV) PET scanners was exploited to develop and evaluate a deep learning (DL) and joint reconstruction-based method to generate µ-maps utilizing background radiation from lutetium-based (LSO) scintillators. METHODS: Data from 18 subjects were used to train convolutional neural networks to enhance initial µ-maps generated using joint activity and attenuation reconstruction algorithm (MLACF) with transmission data from LSO background radiation acquired before and after the administration of 18F-fluorodeoxyglucose (18F-FDG) (µ-mapMLACF-PRE and µ-mapMLACF-POST respectively). The deep learning-enhanced µ-maps (µ-mapDL-MLACF-PRE and µ-mapDL-MLACF-POST) were compared against MLACF-derived and CT-based maps (µ-mapCT). The performance of the method was also evaluated by assessing PET images reconstructed using each µ-map and computing volume-of-interest based standard uptake value measurements and percentage relative mean error (rME) and relative mean absolute error (rMAE) relative to CT-based method. RESULTS: No statistically significant difference was observed in rME values for µ-mapDL-MLACF-PRE and µ-mapDL-MLACF-POST both in fat-based and water-based soft tissue as well as bones, suggesting that presence of the radiopharmaceutical activity in the body had negligible effects on the resulting µ-maps. The rMAE values µ-mapDL-MLACF-POST were reduced by a factor of 3.3 in average compared to the rMAE of µ-mapMLACF-POST. Similarly, the average rMAE values of PET images reconstructed using µ-mapDL-MLACF-POST (PETDL-MLACF-POST) were 2.6 times smaller than the average rMAE values of PET images reconstructed using µ-mapMLACF-POST. The mean absolute errors in SUV values of PETDL-MLACF-POST compared to PETCT were less than 5% in healthy organs, less than 7% in brain grey matter and 4.3% for all tumours combined. CONCLUSION: We describe a deep learning-based method to accurately generate µ-maps from PET emission data and LSO background radiation, enabling CT-free attenuation and scatter correction in LAFOV PET scanners.
PURPOSE: Attenuation correction is a critically important step in data correction in positron emission tomography (PET) image formation. The current standard method involves conversion of Hounsfield units from a computed tomography (CT) image to construct attenuation maps (µ-maps) at 511 keV. In this work, the increased sensitivity of long axial field-of-view (LAFOV) PET scanners was exploited to develop and evaluate a deep learning (DL) and joint reconstruction-based method to generate µ-maps utilizing background radiation from lutetium-based (LSO) scintillators. METHODS: Data from 18 subjects were used to train convolutional neural networks to enhance initial µ-maps generated using joint activity and attenuation reconstruction algorithm (MLACF) with transmission data from LSO background radiation acquired before and after the administration of 18F-fluorodeoxyglucose (18F-FDG) (µ-mapMLACF-PRE and µ-mapMLACF-POST respectively). The deep learning-enhanced µ-maps (µ-mapDL-MLACF-PRE and µ-mapDL-MLACF-POST) were compared against MLACF-derived and CT-based maps (µ-mapCT). The performance of the method was also evaluated by assessing PET images reconstructed using each µ-map and computing volume-of-interest based standard uptake value measurements and percentage relative mean error (rME) and relative mean absolute error (rMAE) relative to CT-based method. RESULTS: No statistically significant difference was observed in rME values for µ-mapDL-MLACF-PRE and µ-mapDL-MLACF-POST both in fat-based and water-based soft tissue as well as bones, suggesting that presence of the radiopharmaceutical activity in the body had negligible effects on the resulting µ-maps. The rMAE values µ-mapDL-MLACF-POST were reduced by a factor of 3.3 in average compared to the rMAE of µ-mapMLACF-POST. Similarly, the average rMAE values of PET images reconstructed using µ-mapDL-MLACF-POST (PETDL-MLACF-POST) were 2.6 times smaller than the average rMAE values of PET images reconstructed using µ-mapMLACF-POST. The mean absolute errors in SUV values of PETDL-MLACF-POST compared to PETCT were less than 5% in healthy organs, less than 7% in brain grey matter and 4.3% for all tumours combined. CONCLUSION: We describe a deep learning-based method to accurately generate µ-maps from PET emission data and LSO background radiation, enabling CT-free attenuation and scatter correction in LAFOV PET scanners.
Authors: T Beyer; D W Townsend; T Brun; P E Kinahan; M Charron; R Roddy; J Jerin; J Young; L Byars; R Nutt Journal: J Nucl Med Date: 2000-08 Impact factor: 10.057
Authors: C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess Journal: Eur J Nucl Med Mol Imaging Date: 2002-04-19 Impact factor: 9.236
Authors: Yuji Nakamoto; Medhat Osman; Christian Cohade; Laura T Marshall; Jonathan M Links; Steve Kohlmyer; Richard L Wahl Journal: J Nucl Med Date: 2002-09 Impact factor: 10.057
Authors: George A Prenosil; Hasan Sari; Markus Fürstner; Ali Afshar-Oromieh; Kuangyu Shi; Axel Rominger; Michael Hentschel Journal: J Nucl Med Date: 2021-07-22 Impact factor: 10.057
Authors: Benjamin A Spencer; Eric Berg; Jeffrey P Schmall; Negar Omidvari; Edwin K Leung; Yasser G Abdelhafez; Songsong Tang; Zilin Deng; Yun Dong; Yang Lv; Jun Bao; Weiping Liu; Hongdi Li; Terry Jones; Ramsey D Badawi; Simon R Cherry Journal: J Nucl Med Date: 2020-10-02 Impact factor: 10.057
Authors: Joel S Karp; Varsha Viswanath; Michael J Geagan; Gerd Muehllehner; Austin R Pantel; Michael J Parma; Amy E Perkins; Jeffrey P Schmall; Matthew E Werner; Margaret E Daube-Witherspoon Journal: J Nucl Med Date: 2019-06-21 Impact factor: 11.082
Authors: Ian Alberts; Robin Schepers; Konstantinos Zeimpekis; Hasan Sari; Axel Rominger; Ali Afshar-Oromieh Journal: Eur J Nucl Med Mol Imaging Date: 2022-09-22 Impact factor: 10.057