Literature DB >> 33134653

Total Body PET: Why, How, What for?

Suleman Surti1, Austin R Pantel1, Joel S Karp2.   

Abstract

PET instruments are now available with a long axial field-of-view (LAFOV) to enable imaging the total-body, or at least head and torso, simultaneously and without bed translation. This has two major benefits, a dramatic increase in system sensitivity and the ability to measure kinetics with wider axial coverage so as to include multiple organs. This manuscript presents a review of the technology leading up to the introduction of these new instruments, and explains the benefits of a LAFOV PET-CT instrument. To date there are two platforms developed for TB-PET, an outcome of the EXPLORER Consortium of the University of California at Davis (UC Davis) and the University of Pennsylvania (Penn). The uEXPLORER at UC Davis has an AFOV of 194 cm and was developed by United Imaging Healthcare. The PennPET EXPLORER was developed at Penn and is based on the digital detector from Philips Healthcare. This multi-ring system is scalable and has been tested with 3 rings but is now being expanded to 6 rings for 140 cm. Initial human studies with both EXPLORER systems have demonstrated the successful implementation and benefits of LAFOV scanners for both clinical and research applications. Examples of such studies are described in this manuscript.

Entities:  

Keywords:  (TB-PET); Long axial-field-of-view (LAFOV); PET-CT; PennPET EXPLORER; Total-Body PET; uEXPLORER

Year:  2020        PMID: 33134653      PMCID: PMC7595297          DOI: 10.1109/trpms.2020.2985403

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  48 in total

1.  90Y PET-based dosimetry after selective internal radiotherapy treatments.

Authors:  Marco D'Arienzo; Paola Chiaramida; Laura Chiacchiararelli; Angela Coniglio; Roberto Cianni; Rita Salvatori; Alberto Ruzza; Francesco Scopinaro; Oreste Bagni
Journal:  Nucl Med Commun       Date:  2012-06       Impact factor: 1.690

2.  Time-of-flight positron emission tomography: status relative to conventional PET.

Authors:  T F Budinger
Journal:  J Nucl Med       Date:  1983-01       Impact factor: 10.057

Review 3.  Update on 18F-Fluciclovine PET for Prostate Cancer Imaging.

Authors:  Ephraim E Parent; David M Schuster
Journal:  J Nucl Med       Date:  2018-03-09       Impact factor: 10.057

Review 4.  Total-body imaging: Transforming the role of positron emission tomography.

Authors:  Simon R Cherry; Ramsey D Badawi; Joel S Karp; William W Moses; Pat Price; Terry Jones
Journal:  Sci Transl Med       Date:  2017-03-15       Impact factor: 17.956

5.  [18F](2S,4R)4-Fluoroglutamine PET Detects Glutamine Pool Size Changes in Triple-Negative Breast Cancer in Response to Glutaminase Inhibition.

Authors:  Rong Zhou; Austin R Pantel; Shihong Li; Brian P Lieberman; Karl Ploessl; Hoon Choi; Eric Blankemeyer; Hsiaoju Lee; Hank F Kung; Robert H Mach; David A Mankoff
Journal:  Cancer Res       Date:  2017-02-15       Impact factor: 12.701

6.  Study of PET scanner designs using clinical metrics to optimize the scanner axial FOV and crystal thickness.

Authors:  S Surti; M E Werner; J S Karp
Journal:  Phys Med Biol       Date:  2013-05-17       Impact factor: 3.609

Review 7.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

8.  A 32 mm  ×  32 mm  ×  22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI.

Authors:  Giacomo Borghi; Bart Jan Peet; Valerio Tabacchini; Dennis R Schaart
Journal:  Phys Med Biol       Date:  2016-06-10       Impact factor: 3.609

9.  μ-opioid receptor system mediates reward processing in humans.

Authors:  Lauri Nummenmaa; Tiina Saanijoki; Lauri Tuominen; Jussi Hirvonen; Jetro J Tuulari; Pirjo Nuutila; Kari Kalliokoski
Journal:  Nat Commun       Date:  2018-04-16       Impact factor: 14.919

10.  PennPET Explorer: Design and Preliminary Performance of a Whole-Body Imager.

Authors:  Joel S Karp; Varsha Viswanath; Michael J Geagan; Gerd Muehllehner; Austin R Pantel; Michael J Parma; Amy E Perkins; Jeffrey P Schmall; Matthew E Werner; Margaret E Daube-Witherspoon
Journal:  J Nucl Med       Date:  2019-06-21       Impact factor: 11.082

View more
  13 in total

1.  Clinical perspectives for the use of total body PET/CT.

Authors:  Ronan Abgral; David Bourhis; Pierre-Yves Salaun
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-06       Impact factor: 9.236

2.  Quantitative evaluation of a deep learning-based framework to generate whole-body attenuation maps using LSO background radiation in long axial FOV PET scanners.

Authors:  Hasan Sari; Mohammadreza Teimoorisichani; Clemens Mingels; Ian Alberts; Vladimir Panin; Deepak Bharkhada; Song Xue; George Prenosil; Kuangyu Shi; Maurizio Conti; Axel Rominger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-07-19       Impact factor: 10.057

3.  Quantifying bias and precision of kinetic parameter estimation on the PennPET Explorer, a long axial field-of-view scanner.

Authors:  Varsha Viswanath; Austin R Pantel; Margaret E Daube-Witherspoon; Robert Doot; Mark Muzi; David A Mankoff; Joel S Karp
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-09-02

Review 4.  Oncologic Applications of Long Axial Field-of-View PET/Computed Tomography.

Authors:  Lorenzo Nardo; Austin R Pantel
Journal:  PET Clin       Date:  2021-01

Review 5.  Pitfalls on PET/CT Due to Artifacts and Instrumentation.

Authors:  Yu-Jung Tsai; Chi Liu
Journal:  Semin Nucl Med       Date:  2021-07-07       Impact factor: 4.446

6.  Assessment of population-based input functions for Patlak imaging of whole body dynamic 18F-FDG PET.

Authors:  Mika Naganawa; Jean-Dominique Gallezot; Vijay Shah; Tim Mulnix; Colin Young; Mark Dias; Ming-Kai Chen; Anne M Smith; Richard E Carson
Journal:  EJNMMI Phys       Date:  2020-11-23

Review 7.  Reinventing Molecular Imaging with Total-Body PET, Part II: Clinical Applications.

Authors:  Babak Saboury; Michael A Morris; Moozhan Nikpanah; Thomas J Werner; Elizabeth C Jones; Abass Alavi
Journal:  PET Clin       Date:  2020-10

8.  Principles of Tracer Kinetic Analysis in Oncology, Part II: Examples and Future Directions.

Authors:  Austin R Pantel; Varsha Viswanath; Mark Muzi; Robert K Doot; David A Mankoff
Journal:  J Nucl Med       Date:  2022-04       Impact factor: 11.082

9.  Performance Characteristics of Long Axial Field-of-View PET Scanners with Axial Gaps.

Authors:  Margaret E Daube-Witherspoon; Varsha Viswanath; Matthew E Werner; Joel S Karp
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-09-28

Review 10.  PET/CT imaging for evaluation of multimodal treatment efficacy and toxicity in advanced NSCLC-current state and future directions.

Authors:  Chukwuka Eze; Nina-Sophie Schmidt-Hegemann; Lino Morris Sawicki; Julian Kirchner; Olarn Roengvoraphoj; Lukas Käsmann; Lena M Mittlmeier; Wolfgang G Kunz; Amanda Tufman; Julien Dinkel; Jens Ricke; Claus Belka; Farkhad Manapov; Marcus Unterrainer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-03-24       Impact factor: 9.236

View more