| Literature DB >> 35813133 |
Hiroki Shimizu1, Takanobu Saito1, Chika Kouno1, Kanako Shimoura1, Rika Kawabe1, Yuki Shinohara1, Kohei Mukaiyama1, Chen Changyu1, Masaya Kato1, Momoko Nagai-Tanima1, Tomoki Aoyama1.
Abstract
Background: Shoulder range of motion (ROM) is one of the most important indicators of shoulder disease severity, function, and physical assessment. A universal goniometer (UG) was used as a gold standard for ROM measurement. Recently, smartphone applications for ROM measurement have attracted attention as alternatives to UG. This study aimed to investigate the validity and reliability of active ROM measurements using a smartphone application goniometer that can be used by patients in a standing position.Entities:
Keywords: Goniometer; Intraclass correlation coefficient; Reliability; Shoulder range of motion; Smartphone; Validity
Year: 2022 PMID: 35813133 PMCID: PMC9264016 DOI: 10.1016/j.jseint.2022.04.005
Source DB: PubMed Journal: JSES Int ISSN: 2666-6383
Characteristics of the study participants (n = 19).
| Characteristics | Mean (SD) |
|---|---|
| Age, yr | 25.7 (4.4) |
| Body mass index, kg/m2 | 21.2 (1.9) |
| Frequency (%) | |
| Gender | |
| Male | 5 (26.3) |
| Female | 14 (73.7) |
| Sides evaluated (dominant upper limb) | |
| Right | 17(89.5) |
| Left | 2 (10.5) |
SD, standard deviation.
The agreement of the smartphone application relative to the goniometer: a Brand-Altman analysis.
| Movement | Observer 1 (%) | Observer 2 (%) |
|---|---|---|
| FF | 100 | 100 |
| EXT | 79 | 100 |
| ABD | 100 | 100 |
| ERS | 100 | 95 |
| ER90ABD | 100 | 100 |
| IR90ABD | 53 | 42 |
| ER90FF | 89 | 84 |
| IR90FF | 100 | 100 |
FF, forward flexion; EXT, extension; ABD, abduction; ERS, external rotation with the arm at the sides; ER90ABD, external rotation at 90° abduction; IR90ABD, internal rotation at 90° abduction; ER90FF, external rotation at 90° forward flexion; IR90FF, internal rotation at 90° forward flexion.
Validity of smartphone applications goniometers for active shoulder ROM.
| Movement | ICC (3, 1) (95% confidence interval) | |
|---|---|---|
| Observer 1 | Observer 2 | |
| FF | 0.94 (0.84-0.97) | 0.94 (0.84-0.96) |
| EXT | 0.72 (0.40-0.89) | 0.78 (0.51-0.91) |
| ABD | 0.94 (0.86-0.98) | 0.97 (0.92-0.99) |
| ERS | 0.91 (0.78-0.96) | 0.85 (0.66-0.94) |
| ER90ABD | 0.91 (0.77-0.96) | 0.94 (0.85-0.98) |
| IR90ABD | 0.87 (0.70-0.95) | 0.85 (0.65-0.94) |
| ER90FF | 0.83 (0.61-0.93) | 0.93 (0.84-0.97) |
| IR90FF | 0.85 (0.64-0.94) | 0.81 (0.56-0.92) |
ROM, range of motion; ICC, intraclass correlation coefficient; FF, forward flexion; EXT, extension; ABD, abduction; ERS, external rotation with the arm at the sides; ER90ABD, external rotation at 90° abduction; IR90ABD, internal rotation at 90° abduction; ER90FF, external rotation at 90° forward flexion; IR90FF, internal rotation at 90° forward flexion.
The fixed biases of the smart phone application relative to the goniometer: a Brand-Altman plot.
| Movement | 95% Confidence interval | |
|---|---|---|
| Observer 1 | Observer 2 | |
| FF | −0.72 to 5.10 | −1.36 to 4.13 |
| EXT | −3.11 to 1.36 | −1.61 to 1.85 |
| ABD | −7.33 to −2.07 | −5.68 to −1.65 |
| ERS | −1.59 to 2.22 | −3.59 to 0.96 |
| ER90ABD | 0.31 to 5.84 | −0.50 to 4.32 |
| IR90ABD | 2.56 to 7.58 | 3.52 to 8.98 |
| ER90FF | −0.39 to 0.48 | 0.40 to 3.38 |
| IR90FF | −0.65 to 4.52 | −0.61 to 4.89 |
FF, forward flexion; EXT, extension; ABD, abduction; ERS, external rotation with the arm at the sides; ER90ABD, external rotation at 90° abduction; IR90ABD, internal rotation at 90° abduction; ER90FF, external rotation at 90° forward flexion; IR90FF, internal rotation at 90° forward flexion.
The proportional biases of the smart phone application relative to the goniometer: a Brand-Altman plot.
| Movement | Correlation coefficients ( | |
|---|---|---|
| Observer 1 | Observer 2 | |
| FF | 0.13 (.59) | 0.42 (.07) |
| EXT | 0.04 (.88) | 0.56 (.01) |
| ABD | 0.53 (.02) | 0.36 (.13) |
| ERS | 0.13 (.60) | 0.30 (.21) |
| ER90ABD | 0.32 (.18) | −0.07 (.78) |
| IR90ABD | 0.40 (.09) | 0.37 (.12) |
| ER90FF | 0.46 (.046) | 0.24 (.34) |
| IR90FF | 0.47 (.04) | 0.66 (.002) |
FF, forward flexion; EXT, extension; ABD, abduction; ERS, external rotation with the arm at the sides; ER90ABD, external rotation at 90° abduction; IR90ABD, internal rotation at 90° abduction; ER90FF, external rotation at 90° forward flexion; IR90FF, internal rotation at 90° forward flexion.
P value < .05.
Within-day reliability of the smartphone application goniometer for active shoulder ROM measurement.
| Movement | ICC (1, 1) (95% CI) |
|---|---|
| FF | 0.94 (0.88-0.98) |
| EXT | 0.79 (0.62-0.91) |
| ABD | 0.95 (0.91-0.98) |
| ERS | 0.89 (0.79-0.95) |
| ER90ABD | 0.93 (0.86-0.97) |
| IR90ABD | 0.93 (0.86-0.97) |
| ER90FF | 0.90 (0.80-0.96) |
| IR90FF | 0.91 (0.82-0.96) |
ROM, range of motion; ICC, intraclass correlation coefficient; CI, confidence interval; FF, forward flexion; EXT, extension; ABD, abduction; ERS, external rotation with the arm at the sides; ER90ABD, external rotation at 90° abduction; IR90ABD, internal rotation at 90° abduction; ER90FF, external rotation at 90° forward flexion; IR90FF, internal rotation at 90° forward flexion.
Variability and measurement error of smartphone application goniometer for active shoulder ROM measurement.
| Movement | SEM | MDC90 |
|---|---|---|
| FF | 2.3 | 6.4 |
| EXT | 2.3 | 6.4 |
| ABD | 2.4 | 6.8 |
| ERS | 2.1 | 5.9 |
| ER90ABD | 2.7 | 7.5 |
| IR90ABD | 2.1 | 5.8 |
| ER90FF | 2.2 | 6.2 |
| IR90FF | 1.9 | 5.2 |
ROM, range of motion; SEM, standard error of measurement; MDC, minimally detectable change; FF, forward flexion; EXT, extension; ABD, abduction; ERS, external rotation with the arm at the sides; ER90ABD, external rotation at 90° abduction; IR90ABD, internal rotation at 90° abduction; ER90FF, external rotation at 90° forward flexion; IR90FF, internal rotation at 90° forward flexion.
The agreement of the smartphone application goniometer relative to the goniometer: a Brand-Altman analysis.
| Movement | Observer 1 (%) | Observer 2 (%) |
|---|---|---|
| IR90ABD (orthotic) | 62.5 | 62.5 |
| IR90ABD (tap) | 75.0 | 62.5 |
IR90ABD (orthotic), internal rotation at 90° abduction with wrist orthotics; IR90ABD (tap), internal rotation at 90° abduction with the observers taking over the taps.