Validation of an innovative method of shoulder range-of-motion measurement using a smartphone clinometer application.

Brian C Werner1, Russell E Holzgrefe1, Justin W Griffin1, Matthew L Lyons1, Christopher T Cosgrove1, Joseph M Hart1, Stephen F Brockmeier2.   

Abstract

BACKGROUND: An accurate and reliable measurement of shoulder range of motion (ROM) is important in the evaluation of the shoulder. A smartphone digital clinometer application is a potentially simpler method for measuring shoulder ROM. The goal of this study was to establish the reliability and validity of shoulder ROM measurements among varying health care providers using a smartphone clinometer application in healthy and symptomatic adults.
METHODS: An attending surgeon, fellow, resident, physician assistant, and student served as examiners. Bilateral shoulders of 24 healthy subjects were included. Fifteen postoperative patients served as the symptomatic cohort. Examiners measured ROM of each shoulder, first using visual estimation and then using a goniometer and smartphone clinometer in a randomized fashion.
RESULTS: The interobserver reliability among examiners showed significant correlation, with average intraclass correlation coefficient [ICC(2,1)] values of 0.61 (estimation), 0.69 (goniometer), and 0.80 (smartphone). All 5 examiners had substantial agreement with the gold standard in healthy subjects, with average ICC(2,1) values ranging from 0.62 to 0.79. The interobserver reliability in symptomatic patients showed significant correlation, with average ICC(2,1) values of 0.72 (estimation), 0.79 (goniometer), and 0.89 (smartphone). Examiners had excellent agreement with the gold standard in symptomatic patients, with an average ICC(2,1) value of 0.98.
CONCLUSION: The smartphone clinometer has excellent agreement with a goniometer-based gold standard for measurement of shoulder ROM in both healthy and symptomatic subjects. There is good correlation among different skill levels of providers for measurements obtained using the smartphone. A smartphone-based clinometer is a good resource for shoulder ROM measurement in both healthy subjects and symptomatic patients.
Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Shoulder range of motion; goniometer; intraclass correlation coefficient; intraobserver reliability; smartphone

Mesh:

Year:  2014        PMID: 24925699     DOI: 10.1016/j.jse.2014.02.030

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  29 in total

Review 1.  Enthesis Repair: Challenges and Opportunities for Effective Tendon-to-Bone Healing.

Authors:  Kathleen A Derwin; Leesa M Galatz; Anthony Ratcliffe; Stavros Thomopoulos
Journal:  J Bone Joint Surg Am       Date:  2018-08-15       Impact factor: 5.284

2.  Shoulder Range of Motion Deficits in Youth Throwers Presenting With Elbow Pain.

Authors:  Michael Rosen; Karim Meijer; Scott Tucker; C Luke Wilcox; Hillary A Plummer; James R Andrews; Roger V Ostrander
Journal:  Sports Health       Date:  2021-08-20       Impact factor: 4.355

3.  EVALUATING THE RELATIONSHIP BETWEEN CLINICAL ASSESSMENTS OF APPARENT HAMSTRING TIGHTNESS: A CORRELATIONAL ANALYSIS.

Authors:  Brittany L Hansberger; Rick Loutsch; Christy Hancock; Robert Bonser; Alli Zeigel; Russell T Baker
Journal:  Int J Sports Phys Ther       Date:  2019-04

Review 4.  The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature.

Authors:  Suzanne F van Rijn; Elisa L Zwerus; Koen Lm Koenraadt; Wilco Ch Jacobs; Michel Pj van den Bekerom; Denise Eygendaal
Journal:  Shoulder Elbow       Date:  2018-06-03

5.  A NOVEL APPROACH TO TREATMENT UTILIZING BREATHING AND A TOTAL MOTION RELEASE® EXERCISE PROGRAM IN A HIGH SCHOOL CHEERLEADER WITH A DIAGNOSIS OF FROZEN SHOULDER: A CASE REPORT.

Authors:  Krystal A Tyree; James May
Journal:  Int J Sports Phys Ther       Date:  2018-08

6.  The Elbow Physical Examination for Telemedicine Encounters.

Authors:  Cort D Lawton; Stephanie Swensen-Buza; Jakob F Awender; Sridhar Pinnamaneni; Joseph D Lamplot; Warren K Young; Scott A Rodeo; Danyal H Nawabi; Samuel A Taylor; Joshua S Dines
Journal:  HSS J       Date:  2021-02-21

7.  Studying Upper-Limb Kinematics Using Inertial Sensors Embedded in Mobile Phones.

Authors:  Cristina Roldan-Jimenez; Antonio Cuesta-Vargas; Paul Bennett
Journal:  JMIR Rehabil Assist Technol       Date:  2015-05-20

8.  Heightened clinical utility of smartphone versus body-worn inertial system for shoulder function B-B score.

Authors:  Claude Pichonnaz; Kamiar Aminian; Céline Ancey; Hervé Jaccard; Estelle Lécureux; Cyntia Duc; Alain Farron; Brigitte M Jolles; Nigel Gleeson
Journal:  PLoS One       Date:  2017-03-20       Impact factor: 3.240

Review 9.  Mobile Phone-Based Joint Angle Measurement for Functional Assessment and Rehabilitation of Proprioception.

Authors:  Quentin Mourcou; Anthony Fleury; Bruno Diot; Céline Franco; Nicolas Vuillerme
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

10.  Pectoralis Minor Contracture in Throwing Shoulders of Asymptomatic Adolescent Baseball Players.

Authors:  Justin L Hodgins; William Rubenstein; David Kovacevic; Ajay Padaki; Charles M Jobin; Christopher S Ahmad
Journal:  Orthop J Sports Med       Date:  2017-09-20
View more